0805L010 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (maximum current without tripping, 25 °C still air) I hold 0.1 A 25 °C still air; same for all 0805L010 voltage variants (/9XR, /12XR, /15XR, /24XR, /33AR, /48AR) 2
Trip current (minimum current at which device trips, 25 °C still air) I trip 0.3 A 25 °C still air; same for all 0805L010 voltage variants 2
Maximum fault current withstood at rated voltage I max 40 A at rated voltage V max; same for all 0805L010 voltage variants 2
Power dissipated in tripped state P d 0.5 W typical, tripped state at 25 °C still air 2
Maximum time to trip T trip 1.5 s at assigned current 0.50 A (5× hold current) 2
Minimum initial resistance (un-soldered) R min 0.75 Ω initial un-soldered state, 0805L010 variants 2
Maximum resistance after trip or reflow R 1max 6 Ω 25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s 2
Resistance change after passive aging -5 5 % +85 °C, 1000 hours; printed ±5% typical 4
Resistance change after humidity aging -5 5 % +85 °C, 85% R.H., 168 hours; printed ±5% typical 4
Resistance change after thermal shock -33 33 % +85 °C to -40 °C, 20 times; printed ±33% typical 4
Ambient operating temperature -40 85 °C Ambient operating conditions for 0805L series 4
Maximum surface temperature in tripped state 125 °C device in tripped state 4
Storage temperature (packaged product) 0 30 °C storage condition, 30%-60% RH 6
Peak reflow temperature Tp 260 °C Pb-free reflow profile peak temperature; time within 5 °C of peak 20-40 s 6

CAD (KiCad official)

  • Symbol: 0805L010
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 02a164fafb86ec79, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF