main
Ray
Publish 0.1.0
e0667c1
0805L005
LUTE · Resettable Fuses · 0805
0805L005 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Minimum resistance (R min) | R min | 1 | Ω | Electrical characteristics at 23℃; 0805L005 variants | 1 | ||
| Maximum resistance (R 1max) | R1max | 38 | Ω | Electrical characteristics at 23℃; 0805L005 variants | 1 | ||
| Time to trip (max) | 0.08 | s | Time to trip at 0.50 A current | 1 | |||
| Maximum interrupt current | I max | 40 | A | 0805L005 variants (all voltage codes) | 1 | ||
| Maximum voltage rating | V max | 16 | Vdc | Ordering code 0805L005/16XRTW | 1 | ||
| Maximum voltage rating | V max | 24 | Vdc | Ordering code 0805L005/24XRTW | 1 | ||
| Maximum voltage rating | V max | 33 | Vdc | Ordering code 0805L005/33XRTW | 1 | ||
| Maximum voltage rating | V max | 48 | Vdc | Ordering code 0805L005/48XRTW | 1 | ||
| Operating temperature range | -40 | 125 | ℃ | Temperature range as stated in Features (all 0805L005 variants) | 1 | ||
| Soldering iron welding temperature (max) | 350 | ℃ | Hand/iron soldering; welding position more than 1.5 mm from PTC | 5 | |||
| Soldering iron contact time (max) | 3 | s | Iron contact with solder joint | 5 | |||
| Hold current | I hold | 0.05 | A | Electrical characteristics at 23℃; 0805L005 variants | 1 | ||
| Trip current | I trip | 0.18 | A | Electrical characteristics at 23℃; 0805L005 variants | 1 | ||
| Power dissipation | P d | 0.6 | W | Electrical characteristics at 23℃; 0805L005 variants | 1 | ||
| Hold current derating at -40℃ | 135 | % | Thermal derating of hold current, ambient -40℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at -20℃ | 122 | % | Thermal derating of hold current, ambient -20℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 0℃ | 110 | % | Thermal derating of hold current, ambient 0℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 23℃ | 100 | % | Thermal derating of hold current, ambient 23℃ (reference) | 3 | |||
| Hold current derating at 40℃ | 90 | % | Thermal derating of hold current, ambient 40℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 60℃ | 75 | % | Thermal derating of hold current, ambient 60℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 85℃ | 65 | % | Thermal derating of hold current, ambient 85℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 100℃ | 53 | % | Thermal derating of hold current, ambient 100℃ (base 100% at 23℃) | 3 | |||
| Hold current derating at 125℃ | 40 | % | Thermal derating of hold current, ambient 125℃ (base 100% at 23℃) | 3 |
CAD (KiCad official)
- Symbol:
0805L005 - Footprint:
Fuse:Fuse_0805_2012Metric - 3D model: 0805 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (6 pp, sha256
901f9737cc8a6655, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0805L005
**LUTE** · Resettable Fuses · 0805
0805L005 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0805 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Minimum resistance (R min) | R min | 1 | | | Ω | Electrical characteristics at 23℃; 0805L005 variants | 1 |
| Maximum resistance (R 1max) | R1max | | | 38 | Ω | Electrical characteristics at 23℃; 0805L005 variants | 1 |
| Time to trip (max) | | | | 0.08 | s | Time to trip at 0.50 A current | 1 |
| Maximum interrupt current | I max | | | 40 | A | 0805L005 variants (all voltage codes) | 1 |
| Maximum voltage rating | V max | | | 16 | Vdc | Ordering code 0805L005/16XRTW | 1 |
| Maximum voltage rating | V max | | | 24 | Vdc | Ordering code 0805L005/24XRTW | 1 |
| Maximum voltage rating | V max | | | 33 | Vdc | Ordering code 0805L005/33XRTW | 1 |
| Maximum voltage rating | V max | | | 48 | Vdc | Ordering code 0805L005/48XRTW | 1 |
| Operating temperature range | | -40 | | 125 | ℃ | Temperature range as stated in Features (all 0805L005 variants) | 1 |
| Soldering iron welding temperature (max) | | | | 350 | ℃ | Hand/iron soldering; welding position more than 1.5 mm from PTC | 5 |
| Soldering iron contact time (max) | | | | 3 | s | Iron contact with solder joint | 5 |
| Hold current | I hold | | 0.05 | | A | Electrical characteristics at 23℃; 0805L005 variants | 1 |
| Trip current | I trip | | 0.18 | | A | Electrical characteristics at 23℃; 0805L005 variants | 1 |
| Power dissipation | P d | | 0.6 | | W | Electrical characteristics at 23℃; 0805L005 variants | 1 |
| Hold current derating at -40℃ | | | 135 | | % | Thermal derating of hold current, ambient -40℃ (base 100% at 23℃) | 3 |
| Hold current derating at -20℃ | | | 122 | | % | Thermal derating of hold current, ambient -20℃ (base 100% at 23℃) | 3 |
| Hold current derating at 0℃ | | | 110 | | % | Thermal derating of hold current, ambient 0℃ (base 100% at 23℃) | 3 |
| Hold current derating at 23℃ | | | 100 | | % | Thermal derating of hold current, ambient 23℃ (reference) | 3 |
| Hold current derating at 40℃ | | | 90 | | % | Thermal derating of hold current, ambient 40℃ (base 100% at 23℃) | 3 |
| Hold current derating at 60℃ | | | 75 | | % | Thermal derating of hold current, ambient 60℃ (base 100% at 23℃) | 3 |
| Hold current derating at 85℃ | | | 65 | | % | Thermal derating of hold current, ambient 85℃ (base 100% at 23℃) | 3 |
| Hold current derating at 100℃ | | | 53 | | % | Thermal derating of hold current, ambient 100℃ (base 100% at 23℃) | 3 |
| Hold current derating at 125℃ | | | 40 | | % | Thermal derating of hold current, ambient 125℃ (base 100% at 23℃) | 3 |
## CAD (KiCad official)
- Symbol: `0805L005`
- Footprint: `Fuse:Fuse_0805_2012Metric`
- 3D model: 0805 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0805l005-33xrt-datasheet.pdf) (6 pp, sha256 `901f9737cc8a6655`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0805l005-33xrt-datasheet.pdf)