Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (I hold) I hold 0.05 A Maximum current without tripping, 25 °C still air 1
Trip current (I trip) I trip 0.15 A Minimum current at which device trips, 25 °C still air 1
Maximum voltage (V max) 15 V variant V max 15 Vdc 0805L005/15XR; at rated current (I max) 1
Maximum voltage (V max) 24 V variant V max 24 Vdc 0805L005/24XR; at rated current (I max) 1
Maximum voltage (V max) 33 V variant V max 33 Vdc 0805L005/33XR; at rated current (I max) 1
Maximum voltage (V max) 60 V variant V max 60 Vdc 0805L005/60XR; at rated current (I max) 2
Maximum fault current (I max) I max 40 A At rated voltage (V max) 1
Power dissipation in tripped state (P d) P d 0.5 W Tripped state, 25 °C still air 1
Time to trip (max) T trip 1.5 s At 0.50 A current 1
Minimum initial resistance (R min) R min 1.5 Ω Initial un-soldered state 1
Maximum resistance after trip or reflow (R 1max) R 1max 20 Ω 25 °C, measured 1 h after tripping or 260 °C 20 s reflow 1
Hold current derated at -40 °C I hold 0.07 A Ambient operating temperature -40 °C 4
Hold current derated at -20 °C I hold 0.06 A Ambient operating temperature -20 °C 4
Hold current derated at 0 °C I hold 0.055 A Ambient operating temperature 0 °C 4
Hold current derated at 25 °C I hold 0.05 A Ambient operating temperature 25 °C 4
Hold current derated at 40 °C I hold 0.04 A Ambient operating temperature 40 °C 4
Hold current derated at 50 °C I hold 0.035 A Ambient operating temperature 50 °C 4
Hold current derated at 60 °C I hold 0.03 A Ambient operating temperature 60 °C 4
Hold current derated at 70 °C I hold 0.025 A Ambient operating temperature 70 °C 4
Hold current derated at 85 °C I hold 0.015 A Ambient operating temperature 85 °C 4
Resistance change, passive aging -5 5 % +85 °C, 1000 hours; typical 4
Resistance change, humidity aging -5 5 % +85 °C, 85% R.H., 168 hours; typical 4
Resistance change, thermal shock -33 33 % +85 °C to -40 °C, 20 times; typical 4
Ambient operating temperature TA -40 85 °C Ambient operating conditions 4
Maximum surface temperature in tripped state 125 °C Device in tripped state 4
Storage temperature (storage condition) TSTORE 0 30 °C Storage condition, 30%-60% RH 6

CAD (KiCad official)

  • Symbol: 0805L005
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 02a164fafb86ec79, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF