0805l001-30xr: factory component page (tier=lcsc)

Ray ·174a1d277c · ·parent d8ba2cf
1 file changed +264−31
page.json+264−31
@@ -1,8 +1,11 @@ {+  "schema_version": 1,+  "type": "component",   "slug": "0805l001-30xr",+  "title": "0805L001/30XR",+  "brief": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "version": "0.1.0",-  "type": "component",-  "description": "LUTE Resettable Fuses, 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "license": "CC-BY-SA-4.0",   "tags": [     "component",     "circuit protection",@@ -10,26 +13,6 @@     "factory-2.0.0",     "extractor-text"   ],-  "dependencies": {},-  "hero": {-    "type": "image",-    "path": "docs/hero.png"-  },-  "files": [-    "page.json",-    "README.md",-    "0805l001-30xr.kicad_sym",-    "0805l001-30xr.kicad_mod",-    "0805l001-30xr.glb",-    "0805l001-30xr.step",-    "0805l001-30xr.lbr",-    "docs/hero.png",-    "docs/0805l001-30xr-datasheet.pdf",-    "viewers/symbol.html",-    "viewers/footprint.html",-    "0805l001-30xr-hero.glb",-    "0805l001-30xr-hero.overlay.json"-  ],   "component": {     "mpn": "0805L001/30XR",     "manufacturer": "LUTE",@@ -159,12 +142,12 @@         "origin": "footprint origin = pad-pattern centre",         "seat": "z = 0",         "extents_mm": [-          2,+          2.0,           1.25,           0.45         ],-        "zmin_mm": 0,-        "centre_offset_mm": 0,+        "zmin_mm": -0.0,+        "centre_offset_mm": 0.0,         "footprint_binding": "identity",         "sha256": "bd29ccc62530d3bcfbbe078f12aac2a99ac75d01c043a2723a4bd36540aac146",         "checked": "2026-11-20",@@ -177,7 +160,7 @@       "D": {         "nom_mm": 2.15,         "range_mm": [-          2,+          2.0,           2.3         ]       },@@ -206,9 +189,259 @@       }     }   },-  "visibility": "private",-  "org": "adom",+  "metadata": {+    "specs": {+      "Manufacturer": "LUTE",+      "Package": "0805",+      "Category": "Circuit Protection",+      "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "41c4fdb5519a0c20f8bc3984026ad5c6c356c8988679423ad2a764947093fa85",+      "rows": [+        {+          "name": "Maximum voltage (V max), 0805L001/30XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "Voltage variant /30XR (ordering code 0805L001/30XR); maximum voltage device withstands without damage at rated current I max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (V max), 0805L001/60XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "Voltage variant /60XR (ordering code 0805L001/60XR); maximum voltage device withstands without damage at rated current I max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum voltage (V max), 0805L001/90XR",+          "symbol": "V max",+          "kind": "absolute_maximum",+          "unit": "Vdc",+          "min": null,+          "typ": null,+          "max": 90,+          "conditions": "Voltage variant /90XR (ordering code 0805L001/90XR); maximum voltage device withstands without damage at rated current I max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current (I max), 0805L001/30XR and /60XR",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "Ordering codes 0805L001/30XR and 0805L001/60XR; maximum fault current device withstands without damage at rated voltage V max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Maximum fault current (I max), 0805L001/90XR",+          "symbol": "I max",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "Ordering code 0805L001/90XR; maximum fault current device withstands without damage at rated voltage V max",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Ambient operating temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "Ambient operating conditions stated for the series",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Maximum surface temperature in tripped state",+          "symbol": "",+          "kind": "thermal",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 125,+          "conditions": "Maximum surface temperature of the device in the tripped state",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": 0,+          "typ": null,+          "max": 30,+          "conditions": "Storage condition, 30%-60% RH",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Hold current (I hold)",+          "symbol": "I hold",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.01,+          "conditions": "25°C still air; maximum current device passes without tripping (datasheet definition); printed value 0.01",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Trip current (I trip)",+          "symbol": "I trip",+          "kind": "electrical",+          "unit": "A",+          "min": 0.03,+          "typ": null,+          "max": null,+          "conditions": "25°C still air; minimum current at which device trips (datasheet definition); printed value 0.03",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance R min (initial, un-soldered)",+          "symbol": "R min",+          "kind": "electrical",+          "unit": "Ω",+          "min": 15,+          "typ": null,+          "max": null,+          "conditions": "Initial un-soldered state; minimum resistance before soldering",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance R1max (after trip or reflow)",+          "symbol": "R1max",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 120,+          "conditions": "25°C, measured one hour after tripping or after reflow soldering of 260°C for 20 sec",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Time to trip (max)",+          "symbol": "T trip",+          "kind": "timing",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "At assigned current 0.20 A (5x hold current), 25°C still air",+          "source_page": 1,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, passive aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 1000 hours; typical value (printed ±5% typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, humidity aging",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -5,+          "typ": null,+          "max": 5,+          "conditions": "+85°C, 85% R.H., 168 hours; typical value (printed ±5% typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Resistance change, thermal shock",+          "symbol": "",+          "kind": "tolerance",+          "unit": "%",+          "min": -33,+          "typ": null,+          "max": 33,+          "conditions": "+85°C to -40°C, 20 times; typical value (printed ±33% typical)",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Power dissipated in tripped state (P d)",+          "symbol": "P d",+          "kind": "electrical",+          "unit": "W",+          "min": null,+          "typ": 0.5,+          "max": null,+          "conditions": "25°C still air, device in tripped state (typical)",+          "source_page": 1,+          "source": "datasheet"+        }+      ]+    }+  },+  "variants": [],+  "sections": [+    "hero",+    "viewers",+    "readme",+    "breadcrumbs",+    "info"+  ],+  "discovery_triggers": [+    "0805l001"+  ],+  "discovery_pitch": "0805L001 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",   "author": {-    "name": "Ray"-  }-}\ No newline at end of file+    "name": "Ray",+    "email": "[email protected]"+  },+  "dependencies": {},+  "hero": {+    "type": "image",+    "path": "docs/hero.png"+  },+  "files": [+    "page.json",+    "README.md",+    "0805l001-30xr.kicad_sym",+    "0805l001-30xr.kicad_mod",+    "0805l001-30xr.glb",+    "0805l001-30xr.step",+    "0805l001-30xr.lbr",+    "docs/hero.png",+    "docs/0805l001-30xr-datasheet.pdf",+    "viewers/symbol.html",+    "viewers/footprint.html",+    "0805l001-30xr-hero.glb",+    "0805l001-30xr-hero.overlay.json"+  ]+}