Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0805L001

LUTE · Resettable Fuses · 0805

0805L001 from LUTE, in a 0805. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0805
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Maximum voltage (V max), 0805L001/30XR V max 30 Vdc Voltage variant /30XR (ordering code 0805L001/30XR); maximum voltage device withstands without damage at rated current I max 1
Maximum voltage (V max), 0805L001/60XR V max 60 Vdc Voltage variant /60XR (ordering code 0805L001/60XR); maximum voltage device withstands without damage at rated current I max 1
Maximum voltage (V max), 0805L001/90XR V max 90 Vdc Voltage variant /90XR (ordering code 0805L001/90XR); maximum voltage device withstands without damage at rated current I max 1
Maximum fault current (I max), 0805L001/30XR and /60XR I max 20 A Ordering codes 0805L001/30XR and 0805L001/60XR; maximum fault current device withstands without damage at rated voltage V max 1
Maximum fault current (I max), 0805L001/90XR I max 10 A Ordering code 0805L001/90XR; maximum fault current device withstands without damage at rated voltage V max 1
Ambient operating temperature -40 85 °C Ambient operating conditions stated for the series 6
Maximum surface temperature in tripped state 125 °C Maximum surface temperature of the device in the tripped state 6
Storage temperature 0 30 °C Storage condition, 30%-60% RH 8
Hold current (I hold) I hold 0.01 A 25°C still air; maximum current device passes without tripping (datasheet definition); printed value 0.01 1
Trip current (I trip) I trip 0.03 A 25°C still air; minimum current at which device trips (datasheet definition); printed value 0.03 1
Resistance R min (initial, un-soldered) R min 15 Ω Initial un-soldered state; minimum resistance before soldering 1
Resistance R1max (after trip or reflow) R1max 120 Ω 25°C, measured one hour after tripping or after reflow soldering of 260°C for 20 sec 1
Time to trip (max) T trip 1 s At assigned current 0.20 A (5x hold current), 25°C still air 1
Resistance change, passive aging -5 5 % +85°C, 1000 hours; typical value (printed ±5% typical) 6
Resistance change, humidity aging -5 5 % +85°C, 85% R.H., 168 hours; typical value (printed ±5% typical) 6
Resistance change, thermal shock -33 33 % +85°C to -40°C, 20 times; typical value (printed ±33% typical) 6
Power dissipated in tripped state (P d) P d 0.5 W 25°C still air, device in tripped state (typical) 1

CAD (KiCad official)

  • Symbol: 0805L001
  • Footprint: Fuse:Fuse_0805_2012Metric
  • 3D model: 0805 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (11 pp, sha256 41c4fdb5519a0c20, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF