main
History Download
Ray Publish 0.1.0 3c01f70

0603L035

LUTE · Resettable Fuses · 0603

0603L035 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum trip current I trip 0.75 A 25℃ still air; minimum current at which device trips 2
Maximum hold current I hold 0.35 A 25℃ still air; maximum current device passes without tripping 2
Maximum fault current I max 40 A At rated voltage (V max) 2
Typical power dissipated in tripped state P d 0.5 W Tripped state, 25℃ still air 2
Maximum time to trip T trip 0.1 Sec At 8.00 A trip current 2
Minimum initial resistance R min 0.2 Ω Initial, un-soldered state 2
Maximum resistance after trip or reflow R 1max 1.4 Ω 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 sec 2
Passive aging resistance change -5 5 % +85℃, 1000 hours; typical 4
Humidity aging resistance change -5 5 % +85℃, 85% R.H., 168 hours; typical 4
Thermal shock resistance change -33 33 % +85℃ to -40℃, 20 times; typical 4
Ambient operating temperature -40 85 ℃ Ambient operating conditions 4
Maximum surface temperature in tripped state 125 ℃ Device in tripped state 4
Storage temperature 0 30 ℃ Storage condition, 30%-60%RH 6
Peak reflow temperature Tp 260 ℃ Pb-free recommended profile; time within 5℃ of peak 20-40 seconds 6
Hold current at -40℃ ambient I hold 0.47 A Ambient -40℃ (temperature derating table, 0603L035) 5
Hold current at -20℃ ambient I hold 0.41 A Ambient -20℃ (temperature derating table, 0603L035) 5
Hold current at 0℃ ambient I hold 0.38 A Ambient 0℃ (temperature derating table, 0603L035) 5
Hold current at 25℃ ambient I hold 0.35 A Ambient 25℃ (temperature derating table, 0603L035) 5
Hold current at 40℃ ambient I hold 0.29 A Ambient 40℃ (temperature derating table, 0603L035) 5
Hold current at 50℃ ambient I hold 0.26 A Ambient 50℃ (temperature derating table, 0603L035) 5
Hold current at 60℃ ambient I hold 0.24 A Ambient 60℃ (temperature derating table, 0603L035) 5
Hold current at 70℃ ambient I hold 0.2 A Ambient 70℃ (temperature derating table, 0603L035) 5
Hold current at 85℃ ambient I hold 0.14 A Ambient 85℃ (temperature derating table, 0603L035) 5

CAD (KiCad official)

  • Symbol: 0603L035
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).