verification.json Verified: Published by the parts factory: tier lcsc, 2 pins · Ray

0603L030

LUTE · Resettable Fuses · 0603

0603L030 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum resistance, initial (un-soldered) state R min 0.3 Ω Initial un-soldered state; same for 0603L030/6XR and /16XR 2
Maximum resistance at 25℃ after trip or reflow R1max 1.7 Ω 25℃, measured one hour after tripping or reflow soldering 260℃ for 20 s 2
Trip current (minimum) I trip 0.65 A 25℃ still air 2
Maximum fault current at rated voltage I max 40 A At rated voltage (Vmax); same for 0603L030/6XR and /16XR 2
Maximum time to trip 0.1 Sec At 8.00 A trip current 2
Maximum surface temperature in tripped state 125 ℃ Device in tripped state 5
Reflow peak temperature Tp 260 ℃ Lead-free reflow; time within 5℃ of peak 20-40 s; Note 1 measured on package topside 7
Ambient operating temperature TA -40 85 ℃ Ambient operating conditions 5
Storage temperature TSTORE 0 30 ℃ Storage condition, 30%-60%RH 7
Passive aging resistance change -5 5 % +85℃, 1000 hours; typical 5
Humidity aging resistance change -5 5 % +85℃, 85% R.H., 168 hours; typical 5
Thermal shock resistance change -33 33 % +85℃ to -40℃, 20 times; typical 5
Power dissipated in tripped state Pd 0.5 W Tripped state, 25℃ still air 2
Hold current at -40℃ ambient I hold 0.42 A Ambient operating temperature -40℃ 5
Hold current at -20℃ ambient I hold 0.38 A Ambient operating temperature -20℃ 5
Hold current at 0℃ ambient I hold 0.35 A Ambient operating temperature 0℃ 5
Hold current at 25℃ ambient I hold 0.3 A Ambient operating temperature 25℃ 5
Hold current at 40℃ ambient I hold 0.26 A Ambient operating temperature 40℃ 5
Hold current at 50℃ ambient I hold 0.21 A Ambient operating temperature 50℃ 5
Hold current at 60℃ ambient I hold 0.18 A Ambient operating temperature 60℃ 5
Hold current at 70℃ ambient I hold 0.15 A Ambient operating temperature 70℃ 5
Hold current at 85℃ ambient I hold 0.11 A Ambient operating temperature 85℃ 5
Hold current at 25℃ still air I hold 0.3 A 25℃ still air; maximum current device passes without tripping 2

CAD (KiCad official)

  • Symbol: 0603L030
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256 68da16d6f5a1c784, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF