3D Model
Open in new tab ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Symbol & Footprint
Schematic Symbol
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
PCB Footprint
Open full view ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
Datasheet
Open in new tab ↗Loads when you scroll to it. Unloads after 5 minutes in the background.
README
markdown0603L025
LUTE · Resettable Fuses · 0603
0603L025 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0603 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Initial resistance (minimum) | R min | 0.5 | Ω | initial, un-soldered state | 2 | ||
| Trip current (minimum) | I trip | 0.55 | A | 25 °C still air | 2 | ||
| Hold current (maximum) | I hold | 0.25 | A | 25 °C still air | 2 | ||
| Maximum fault current | I max | 40 | A | at rated voltage (V max) | 2 | ||
| Resistance one hour after trip or reflow (maximum) | R 1max | 3 | Ω | 25 °C, one hour after tripping or 260 °C reflow for 20 s | 2 | ||
| Maximum time to trip | T trip | 0.08 | s | at 8.00 A current | 2 | ||
| Power dissipated when tripped | P d | 0.5 | W | tripped state, 25 °C still air | 2 | ||
| Resistance change after passive aging | -5 | 5 | % | typical; +85 °C, 1000 hours | 4 | ||
| Resistance change after humidity aging | -5 | 5 | % | typical; +85 °C, 85% R.H., 168 hours | 4 | ||
| Resistance change after thermal shock | -33 | 33 | % | typical; +85 °C to -40 °C, 20 times | 4 | ||
| Ambient operating temperature | TA | -40 | 85 | °C | ambient operating conditions | 4 | |
| Storage temperature | TSTORE | 0 | 30 | °C | storage, 30%-60% RH | 6 | |
| Maximum surface temperature in tripped state | 125 | °C | device in tripped state | 4 | |||
| Peak reflow temperature | Tp | 260 | °C | Pb-free reflow; time within 5 °C of peak 20-40 s | 6 | ||
| Hold current at -40 °C ambient | I hold | 0.32 | A | ambient -40 °C (derating table) | 5 | ||
| Hold current at -20 °C ambient | I hold | 0.29 | A | ambient -20 °C (derating table) | 5 | ||
| Hold current at 0 °C ambient | I hold | 0.27 | A | ambient 0 °C (derating table) | 5 | ||
| Hold current at 25 °C ambient | I hold | 0.25 | A | ambient 25 °C (derating table) | 5 | ||
| Hold current at 40 °C ambient | I hold | 0.21 | A | ambient 40 °C (derating table) | 5 | ||
| Hold current at 50 °C ambient | I hold | 0.18 | A | ambient 50 °C (derating table) | 5 | ||
| Hold current at 60 °C ambient | I hold | 0.16 | A | ambient 60 °C (derating table) | 5 | ||
| Hold current at 70 °C ambient | I hold | 0.14 | A | ambient 70 °C (derating table) | 5 | ||
| Hold current at 85 °C ambient | I hold | 0.1 | A | ambient 85 °C (derating table) | 5 |
CAD (KiCad official)
- Symbol:
0603L025 - Footprint:
Fuse:Fuse_0603_1608Metric - 3D model: 0603 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256
9b801c861db9e4a6, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).