Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0603L025

LUTE · Resettable Fuses · 0603

0603L025 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (maximum, passes without tripping) I hold 0.25 A 25℃ still air; identical for all 0603L025 voltage variants 2
Trip current (minimum) I trip 0.55 A 25℃ still air; identical for all 0603L025 voltage variants 2
Maximum fault current withstand I max 40 A at rated voltage (V max); identical for all 0603L025 voltage variants 2
Minimum initial resistance (un-soldered) R min 0.5 Ω initial un-soldered state 2
Maximum resistance after trip or reflow R 1max 3 Ω 25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec 2
Maximum time to trip T trip 0.08 Sec at 8.00 A 2
Resistance change, passive aging -5 5 % +85°C, 1000 hours; typical 4
Resistance change, humidity aging -5 5 % +85°C, 85% R.H., 168 hours; typical 4
Resistance change, thermal shock -33 33 % +85°C to -40°C, 20 times; typical 4
Typical power dissipated in tripped state P d typ. 0.5 W tripped state, 25℃ still air 2
Hold current at -40℃ ambient 0.32 A ambient operating temperature -40℃, 0603L025 derating table 5
Hold current at -20℃ ambient 0.29 A ambient operating temperature -20℃, 0603L025 derating table 5
Hold current at 0℃ ambient 0.27 A ambient operating temperature 0℃, 0603L025 derating table 5
Hold current at 25℃ ambient 0.25 A ambient operating temperature 25℃, 0603L025 derating table 5
Hold current at 40℃ ambient 0.21 A ambient operating temperature 40℃, 0603L025 derating table 5
Hold current at 50℃ ambient 0.18 A ambient operating temperature 50℃, 0603L025 derating table 5
Hold current at 60℃ ambient 0.16 A ambient operating temperature 60℃, 0603L025 derating table 5
Hold current at 70℃ ambient 0.14 A ambient operating temperature 70℃, 0603L025 derating table 5
Hold current at 85℃ ambient 0.1 A ambient operating temperature 85℃, 0603L025 derating table 5
Ambient operating temperature -40 85 ℃ ambient operating conditions 4
Maximum surface temperature in tripped state 125 ℃ device in tripped state 4
Storage temperature 0 30 ℃ storage condition, 30%-60%RH 6

CAD (KiCad official)

  • Symbol: 0603L025
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF