main
History Download
Ray Publish 0.1.0 1e4012e

0603L025

LUTE · Resettable Fuses · 0603

0603L025 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum trip current I trip 0.55 A 25℃ still air; minimum current at which the device trips 2
Hold current I hold 0.25 A 25℃ still air; maximum current device passes without tripping (printed as 0.25 with no min/max label) 2
Maximum fault current I max 40 A At rated voltage (V max) 2
Minimum initial resistance R min 0.5 Ω Initial (un-soldered) state 2
Maximum resistance after trip or reflow R 1max 3 Ω 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s 2
Maximum time to trip 0.08 s Time to trip (max.) at assigned current 8.00 A 2
Passive aging resistance change -5 5 % +85℃, 1000 hours; typical 4
Humidity aging resistance change -5 5 % +85℃, 85% R.H., 168 hours; typical 4
Thermal shock resistance change -33 33 % +85℃ to -40℃, 20 times; typical 4
Ambient operating temperature -40 85 °C Ambient operating conditions 4
Maximum surface temperature in tripped state 125 °C Device in tripped state 4
Storage temperature 0 30 °C Storage condition; 30%-60% RH 6
Peak reflow temperature Tp 260 °C Lead-free reflow peak temperature (Tp) 6
Rated power in tripped state P d 0.5 W Typical power dissipated in tripped state, 25℃ still air 2
Maximum voltage (variant 0603L025/6XR) V max 6 Vdc Variant 0603L025/6XR; maximum voltage without damage at rated current 2
Maximum voltage (variant 0603L025/9XR) V max 9 Vdc Variant 0603L025/9XR; maximum voltage without damage at rated current 2
Maximum voltage (variant 0603L025/12XR) V max 12 Vdc Variant 0603L025/12XR; maximum voltage without damage at rated current 2
Maximum voltage (variant 0603L025/16XR) V max 16 Vdc Variant 0603L025/16XR; maximum voltage without damage at rated current 2
Maximum voltage (variant 0603L025/24XR) V max 24 Vdc Variant 0603L025/24XR; maximum voltage without damage at rated current 2
Hold current at ambient I hold 0.32 A Ambient -40℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.29 A Ambient -20℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.27 A Ambient 0℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.25 A Ambient 25℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.21 A Ambient 40℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.18 A Ambient 50℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.16 A Ambient 60℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.14 A Ambient 70℃ (0603L025 family derating table) 5
Hold current at ambient I hold 0.1 A Ambient 85℃ (0603L025 family derating table) 5

CAD (KiCad official)

  • Symbol: 0603L025
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF