main
History Download
Ray Publish 0.1.0 f330646

0603L012

LUTE · Resettable Fuses · 0603

0603L012 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current I hold 0.12 A 25℃ still air; maximum current device passes without tripping (same for all 0603L012 voltage variants) 2
Trip current I trip 0.36 A 25℃ still air; minimum current at which device trips 2
Time to trip (max) 0.2 s at 0.80 A trip-test current 2
Minimum initial resistance R min 0.7 Ω initial un-soldered state 2
Maximum resistance after trip or reflow R1max 6 Ω 25℃, measured one hour after tripping or reflow soldering at 260℃ for 20 s 2
Power dissipated in tripped state Pd 0.7 W typical, tripped state, 25℃ still air 2
Passive aging resistance change -5 5 % +85℃, 1000 hours; typical 5
Humidity aging resistance change -5 5 % +85℃, 85% R.H., 168 hours; typical 5
Thermal shock resistance change -33 33 % +85℃ to -40℃, 20 times; typical 5
Ambient operating temperature TA -40 85 °C ambient operating conditions 5
Maximum surface temperature in tripped state 125 °C device in tripped state 5
Storage temperature TSTORE 0 30 °C storage condition, 30%-60% RH 7
Hold current derating at -40℃ I hold 0.19 A ambient operating temperature -40℃ (0603L012) 6
Hold current derating at -20℃ I hold 0.17 A ambient operating temperature -20℃ (0603L012) 6
Hold current derating at 0℃ I hold 0.15 A ambient operating temperature 0℃ (0603L012) 6
Hold current derating at 25℃ I hold 0.12 A ambient operating temperature 25℃ (0603L012) 6
Hold current derating at 40℃ I hold 0.1 A ambient operating temperature 40℃ (0603L012) 6
Hold current derating at 50℃ I hold 0.09 A ambient operating temperature 50℃ (0603L012) 6
Hold current derating at 60℃ I hold 0.08 A ambient operating temperature 60℃ (0603L012) 6
Hold current derating at 70℃ I hold 0.06 A ambient operating temperature 70℃ (0603L012) 6
Hold current derating at 85℃ I hold 0.05 A ambient operating temperature 85℃ (0603L012) 6

CAD (KiCad official)

  • Symbol: 0603L012
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256 cbbadcaddb0d0e0b, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).