main
Ray
Publish 0.1.0
91b4f42
0603L012
LUTE · Resettable Fuses · 0603
0603L012 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0603 |
| Category | Circuit Protection |
| Pins | 2 |
Electrical characteristics
Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current at ambient temperature -40 ℃ | I hold | 0.19 | A | 0603L012 family derating table, ambient -40 ℃ | 6 | ||
| Hold current at ambient temperature -20 ℃ | I hold | 0.17 | A | 0603L012 family derating table, ambient -20 ℃ | 6 | ||
| Hold current at ambient temperature 0 ℃ | I hold | 0.15 | A | 0603L012 family derating table, ambient 0 ℃ | 6 | ||
| Hold current at ambient temperature 25 ℃ | I hold | 0.12 | A | 0603L012 family derating table, ambient 25 ℃ | 6 | ||
| Hold current at ambient temperature 40 ℃ | I hold | 0.1 | A | 0603L012 family derating table, ambient 40 ℃ | 6 | ||
| Hold current at ambient temperature 50 ℃ | I hold | 0.09 | A | 0603L012 family derating table, ambient 50 ℃ | 6 | ||
| Hold current at ambient temperature 60 ℃ | I hold | 0.08 | A | 0603L012 family derating table, ambient 60 ℃ | 6 | ||
| Hold current at ambient temperature 70 ℃ | I hold | 0.06 | A | 0603L012 family derating table, ambient 70 ℃ | 6 | ||
| Hold current at ambient temperature 85 ℃ | I hold | 0.05 | A | 0603L012 family derating table, ambient 85 ℃ | 6 | ||
| Ambient operating temperature | TA | -40 | 85 | ℃ | Ambient operating conditions, series-wide | 5 | |
| Maximum surface temperature in tripped state | 125 | ℃ | Device in tripped state | 5 |
CAD (KiCad official)
- Symbol:
0603L012 - Footprint:
Fuse:Fuse_0603_1608Metric - 3D model: 0603 (KiCad packages3D, STEP)
Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256
cbbadcaddb0d0e0b, retrieved 2026-11-20) - Extractor: parts-factory
2.0.0/extract_pins, primarytwo-terminal convention(convention), consensusoff(agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish. - CAD: KiCad official libraries (CC-BY-SA 4.0).
# 0603L012
**LUTE** · Resettable Fuses · 0603
0603L012 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.
## Pinout
| Pin | Name | Type | Function |
|---|---|---|---|
| 1 | 1 | passive | Terminal 1 of an unpolarised fuse; either orientation. |
| 2 | 2 | passive | Terminal 2 of an unpolarised fuse; either orientation. |
## Key specifications
| Parameter | Value |
|---|---|
| Manufacturer | LUTE |
| Package | 0603 |
| Category | Circuit Protection |
| Pins | 2 |
## Electrical characteristics
Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).
| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |
|---|---|---|---|---|---|---|---|
| Hold current at ambient temperature -40 ℃ | I hold | | | 0.19 | A | 0603L012 family derating table, ambient -40 ℃ | 6 |
| Hold current at ambient temperature -20 ℃ | I hold | | | 0.17 | A | 0603L012 family derating table, ambient -20 ℃ | 6 |
| Hold current at ambient temperature 0 ℃ | I hold | | | 0.15 | A | 0603L012 family derating table, ambient 0 ℃ | 6 |
| Hold current at ambient temperature 25 ℃ | I hold | | | 0.12 | A | 0603L012 family derating table, ambient 25 ℃ | 6 |
| Hold current at ambient temperature 40 ℃ | I hold | | | 0.1 | A | 0603L012 family derating table, ambient 40 ℃ | 6 |
| Hold current at ambient temperature 50 ℃ | I hold | | | 0.09 | A | 0603L012 family derating table, ambient 50 ℃ | 6 |
| Hold current at ambient temperature 60 ℃ | I hold | | | 0.08 | A | 0603L012 family derating table, ambient 60 ℃ | 6 |
| Hold current at ambient temperature 70 ℃ | I hold | | | 0.06 | A | 0603L012 family derating table, ambient 70 ℃ | 6 |
| Hold current at ambient temperature 85 ℃ | I hold | | | 0.05 | A | 0603L012 family derating table, ambient 85 ℃ | 6 |
| Ambient operating temperature | TA | -40 | | 85 | ℃ | Ambient operating conditions, series-wide | 5 |
| Maximum surface temperature in tripped state | | | | 125 | ℃ | Device in tripped state | 5 |
## CAD (KiCad official)
- Symbol: `0603L012`
- Footprint: `Fuse:Fuse_0603_1608Metric`
- 3D model: 0603 (KiCad packages3D, STEP)
## Provenance
Data extracted from the manufacturer datasheet, not a distributor listing:
- **Datasheet:** [LUTE datasheet, copy hosted by LCSC](docs/0603l012-24xr-datasheet.pdf) (10 pp, sha256 `cbbadcaddb0d0e0b`, retrieved 2026-11-20)
- **Extractor:** parts-factory `2.0.0` / `extract_pins`, primary `two-terminal convention` (convention), consensus `off` (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
- **CAD:** KiCad official libraries (CC-BY-SA 4.0).
[Datasheet PDF](docs/0603l012-24xr-datasheet.pdf)