main
History Download
Ray Publish 0.1.0 d6a2230

0603L008

LUTE · Resettable Fuses · 0603

0603L008 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (maximum current that does not trip) I hold 0.08 A 25 °C still air 2
Trip current (minimum current that trips) I trip 0.24 A 25 °C still air 2
Maximum fault current I max 100 A at rated voltage (Vmax) 2
Initial minimum resistance R min 3 Ω initial un-soldered state 2
Maximum resistance after trip or reflow R1max 14 Ω 25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s 2
Maximum time to trip 0.5 s at 0.50 A assigned current, 25 °C 2
Hold current at -40 °C ambient I hold 0.11 A ambient -40 °C (derating table) 5
Hold current at -20 °C ambient I hold 0.1 A ambient -20 °C (derating table) 5
Hold current at 0 °C ambient I hold 0.09 A ambient 0 °C (derating table) 5
Hold current at 25 °C ambient I hold 0.08 A ambient 25 °C (derating table) 5
Hold current at 40 °C ambient I hold 0.06 A ambient 40 °C (derating table) 5
Hold current at 50 °C ambient I hold 0.05 A ambient 50 °C (derating table) 5
Hold current at 60 °C ambient I hold 0.04 A ambient 60 °C (derating table) 5
Hold current at 70 °C ambient I hold 0.03 A ambient 70 °C (derating table) 5
Hold current at 85 °C ambient I hold 0.02 A ambient 85 °C (derating table) 5
Resistance change, passive aging -5 5 % +85 °C, 1000 hours; typical 4
Resistance change, humidity aging -5 5 % +85 °C, 85% R.H., 168 hours; typical 4
Resistance change, thermal shock -33 33 % +85 °C to -40 °C, 20 times; typical 4
Ambient operating temperature -40 85 °C ambient operating conditions 4
Storage temperature 0 30 °C storage condition 6
Storage relative humidity 30 60 %RH storage condition 6
Preheat start temperature Ts(min) 150 200 °C reflow preheat, Pb-free; preheat time 60-180 s 6
Average ramp-up rate 3 °C/second Ts(max) to Tp, Pb-free reflow 6
Ramp-down rate 6 °C/second Pb-free reflow 6
Time 25 °C to peak temperature 8 minutes Pb-free reflow 6
Time within 5 °C of peak temperature tp 20 40 s Pb-free reflow 6
Maximum surface temperature in tripped state 125 °C device in tripped state 4
Peak reflow temperature Tp 260 °C Pb-free reflow, topside of package 6
Typical power dissipated when tripped P d 0.5 W tripped state, 25 °C still air 2

CAD (KiCad official)

  • Symbol: 0603L008
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF