0603L005

LUTE · Resettable Fuses · 0603

0603L005 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Hold current (maximum current without tripping, 25 °C still air) I hold 0.05 A 25℃ still air; family rows identical for 0603L005 voltage variants 2
Trip current (minimum current to trip, 25 °C still air) I trip 0.15 A 25℃ still air 2
Maximum fault current at rated voltage I max 40 A at rated voltage V max 2
Power dissipated in tripped state P d 0.5 W tripped state, 25℃ still air 2
Maximum time to trip T trip 1 s at 0.25 A (Current (A) column of the table) 2
Minimum initial resistance (un-soldered) R min 3.8 Ω initial, un-soldered state 2
Maximum resistance after trip or reflow R 1max 30 Ω 25℃, measured one hour after tripping or reflow soldering of 260℃ for 20 sec 2
Resistance change, passive aging -5 5 % +85℃, 1000 hours; printed as ±5% typical 4
Resistance change, humidity aging -5 5 % +85℃, 85% R.H., 168 hours; printed as ±5% typical 4
Resistance change, thermal shock -33 33 % +85℃ to -40℃, 20 times; printed as ±33% typical 4
Hold current at ambient -40 ℃ (derating table) I hold 0.065 A ambient -40℃, temperature derating table 5
Hold current at ambient -20 ℃ (derating table) I hold 0.06 A ambient -20℃, temperature derating table 5
Hold current at ambient 0 ℃ (derating table) I hold 0.055 A ambient 0℃, temperature derating table 5
Hold current at ambient 40 ℃ (derating table) I hold 0.04 A ambient 40℃, temperature derating table 5
Hold current at ambient 50 ℃ (derating table) I hold 0.035 A ambient 50℃, temperature derating table 5
Hold current at ambient 60 ℃ (derating table) I hold 0.031 A ambient 60℃, temperature derating table 5
Hold current at ambient 70 ℃ (derating table) I hold 0.025 A ambient 70℃, temperature derating table 5
Hold current at ambient 85 ℃ (derating table) I hold 0.015 A ambient 85℃, temperature derating table 5
Ambient operating temperature TA -40 85 °C ambient operating conditions 4
Maximum surface temperature in tripped state 125 °C device in tripped state 4
Peak reflow temperature Tp 260 °C Pb-free reflow profile, time within 5 °C of peak 20-40 s 6
Storage temperature TSTORE 0 30 °C storage at 30%-60% RH 6

CAD (KiCad official)

  • Symbol: 0603L005
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF