main
Download ZIP Propose a change
Made with kicad-footprint-generator 10.0 · KiCad file format 20260206
Name Last commit message Last updated
docs Publish 0.1.0 · Ray
viewers 0603l005-33ar: viewers · Ray
0603l005-33ar-hero.glb Publish 0.1.0 · Ray
0603l005-33ar-hero.overlay.json Publish 0.1.0 · Ray
0603l005-33ar.glb Publish 0.1.0 · Ray
0603l005-33ar.kicad_mod Publish 0.1.0 · Ray
0603l005-33ar.kicad_sym Publish 0.1.0 · Ray
0603l005-33ar.lbr Publish 0.1.0 · Ray
0603l005-33ar.step Publish 0.1.0 · Ray
package.json Publish 0.1.2 · Ray
page.json Publish 0.1.2 · Ray
README.md Publish 0.1.0 · Ray
verification.json Verified: Published by the parts factory: tier lcsc, 2 pins · Ray

0603L005

LUTE · Resettable Fuses · 0603

0603L005 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum trip current I trip 0.15 A 25 °C still air 2
Minimum initial resistance (un-soldered) R min 3.8 Ω Initial, before soldering 2
Maximum fault current I max 40 A At rated voltage (V max) 2
Maximum time to trip T trip 1 s At 0.25 A current (5× hold current), 25 °C 2
Maximum resistance after trip or reflow R 1max 30 Ω 25 °C, measured one hour after tripping or reflow soldering at 260 °C for 20 s 2
Resistance change, passive aging -5 5 % +85 °C, 1000 hours; printed as ±5% typical 4
Resistance change, humidity aging -5 5 % +85 °C, 85% R.H., 168 hours; printed as ±5% typical 4
Resistance change, thermal shock -33 33 % +85 °C to -40 °C, 20 cycles; printed as ±33% typical 4
Ambient operating temperature TA -40 85 °C Ambient operating conditions 4
Maximum surface temperature in tripped state 125 °C Device in tripped state 4
Peak reflow temperature Tp 260 °C Lead-free reflow; time within 5 °C of peak 20-40 s 6
Storage temperature 0 30 °C Storage, 30%-60% RH 6
Hold current I hold 0.05 A 25 °C still air (maximum current passed without tripping) 2
Hold current at 85 °C ambient I hold 0.015 A Ambient 85 °C, from temperature derating table 5
Typical power dissipated in tripped state P d 0.5 W Tripped state, 25 °C still air 2

CAD (KiCad official)

  • Symbol: 0603L005
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (9 pp, sha256 9b801c861db9e4a6, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF