← Commit history
package.json+240−2@@ -1,6 +1,6 @@ { "slug": "0603l001-72ar",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.", "tags": [@@ -200,5 +200,243 @@ "by": "factory/package_fit.py" } }- }+ },+ "title": "0603L001/72AR",+ "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "LUTE",+ "Package": "0603",+ "Category": "Circuit Protection",+ "Pins": "2"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "85b871c4a68fc4d5736db99edf3d15e1c78d1b049758890203b0b4d55a8714fd",+ "rows": [+ {+ "name": "Minimum resistance (initial, un-soldered state)",+ "symbol": "R min",+ "kind": "electrical",+ "unit": "Ω",+ "min": 15,+ "typ": null,+ "max": null,+ "conditions": "Initial un-soldered state; same for /60AR and /72AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum resistance after trip or reflow",+ "symbol": "R 1max",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s; same for /60AR and /72AR",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Trip current",+ "symbol": "I trip",+ "kind": "electrical",+ "unit": "A",+ "min": 0.03,+ "typ": null,+ "max": null,+ "conditions": "25°C still air; minimum current at which the device trips",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.01,+ "conditions": "25°C still air; maximum current device passes without tripping",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage (variant 0603L001/60AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 60,+ "conditions": "/60AR; at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum voltage (variant 0603L001/72AR)",+ "symbol": "V max",+ "kind": "absolute_maximum",+ "unit": "Vdc",+ "min": null,+ "typ": null,+ "max": 72,+ "conditions": "/72AR; at rated current (I max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current (variant 0603L001/60AR)",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "/60AR; at rated voltage (V max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Maximum fault current (variant 0603L001/72AR)",+ "symbol": "I max",+ "kind": "absolute_maximum",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "/72AR; at rated voltage (V max)",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Time to trip (maximum)",+ "symbol": "",+ "kind": "timing",+ "unit": "s",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "Time to Trip (Max.) at 0.20 A current, as printed for 0603L001 rows",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Hold current at -40 °C (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.016,+ "conditions": "Ambient operating temperature -40℃; derating table for 0603L001",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Hold current at 85 °C (derating)",+ "symbol": "I hold",+ "kind": "electrical",+ "unit": "A",+ "min": null,+ "typ": null,+ "max": 0.0035,+ "conditions": "Ambient operating temperature 85℃; derating table for 0603L001",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Power dissipated in tripped state",+ "symbol": "P d",+ "kind": "electrical",+ "unit": "W",+ "min": null,+ "typ": 0.5,+ "max": null,+ "conditions": "Typical, tripped state at 25°C still air",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, passive aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 1000 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, humidity aging",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "+85°C, 85% R.H., 168 hours; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Resistance change, thermal shock",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -33,+ "typ": null,+ "max": 33,+ "conditions": "+85°C to -40°C, 20 times; typical",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Ambient operating temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ambient operating conditions",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Maximum surface temperature in tripped state",+ "symbol": "",+ "kind": "thermal",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Device in tripped state",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": 0,+ "typ": null,+ "max": 30,+ "conditions": "Storage condition; 30%-60% RH",+ "source_page": 7,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "0603l001"+ ],+ "discovery_pitch": "0603L001 (LUTE) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+5−5@@ -4,7 +4,7 @@ "slug": "0603l001-72ar", "title": "0603L001/72AR", "brief": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -450,7 +450,7 @@ "0603l001-72ar-hero.glb", "0603l001-72ar-hero.overlay.json" ],- "visibility": {- "public": true- }-}+ "visibility": "public",+ "description": "LUTE Resettable Fuses, 0603. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+ "org": "adom"+}