Loads when you scroll to it. Unloads after 5 minutes in the background.

Symbol & Footprint

Schematic Symbol

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.

PCB Footprint

Open full view ↗
Loads when you scroll to it. Unloads after 5 minutes in the background.
Loads when you scroll to it. Unloads after 5 minutes in the background.
Download PDF
Contents

README

markdown

0603L001

LUTE · Resettable Fuses · 0603

0603L001 from LUTE, in a 0603. Pinout and pin descriptions extracted from the manufacturer datasheet (extract_pins, cross-checked by a second model). Symbol, footprint, and 3D from KiCad-official CAD.

Pinout

Pin Name Type Function
1 1 passive Terminal 1 of an unpolarised fuse; either orientation.
2 2 passive Terminal 2 of an unpolarised fuse; either orientation.

Key specifications

Parameter Value
Manufacturer LUTE
Package 0603
Category Circuit Protection
Pins 2

Electrical characteristics

Limits as printed in the datasheet (page.json metadata.characteristics carries them as data).

Parameter Symbol Min Typ Max Unit Conditions Page
Minimum resistance (initial, un-soldered state) R min 15 Ω Initial un-soldered state; same for /60AR and /72AR 1
Maximum resistance after trip or reflow R 1max 100 Ω 25°C, measured one hour after tripping or reflow soldering at 260°C for 20 s; same for /60AR and /72AR 1
Trip current I trip 0.03 A 25°C still air; minimum current at which the device trips 1
Hold current I hold 0.01 A 25°C still air; maximum current device passes without tripping 1
Maximum voltage (variant 0603L001/60AR) V max 60 Vdc /60AR; at rated current (I max) 1
Maximum voltage (variant 0603L001/72AR) V max 72 Vdc /72AR; at rated current (I max) 1
Maximum fault current (variant 0603L001/60AR) I max 20 A /60AR; at rated voltage (V max) 1
Maximum fault current (variant 0603L001/72AR) I max 10 A /72AR; at rated voltage (V max) 1
Time to trip (maximum) 1 s Time to Trip (Max.) at 0.20 A current, as printed for 0603L001 rows 1
Hold current at -40 °C (derating) I hold 0.016 A Ambient operating temperature -40℃; derating table for 0603L001 5
Hold current at 85 °C (derating) I hold 0.0035 A Ambient operating temperature 85℃; derating table for 0603L001 5
Power dissipated in tripped state P d 0.5 W Typical, tripped state at 25°C still air 1
Resistance change, passive aging -5 5 % +85°C, 1000 hours; typical 5
Resistance change, humidity aging -5 5 % +85°C, 85% R.H., 168 hours; typical 5
Resistance change, thermal shock -33 33 % +85°C to -40°C, 20 times; typical 5
Ambient operating temperature TA -40 85 °C Ambient operating conditions 5
Maximum surface temperature in tripped state 125 °C Device in tripped state 5
Storage temperature 0 30 °C Storage condition; 30%-60% RH 7

CAD (KiCad official)

  • Symbol: 0603L001
  • Footprint: Fuse:Fuse_0603_1608Metric
  • 3D model: 0603 (KiCad packages3D, STEP)

Provenance

Data extracted from the manufacturer datasheet, not a distributor listing:

  • Datasheet: LUTE datasheet, copy hosted by LCSC (10 pp, sha256 85b871c4a68fc4d5, retrieved 2026-11-20)
  • Extractor: parts-factory 2.0.0 / extract_pins, primary two-terminal convention (convention), consensus off (agreed), guards: pin_guards 0.1: passed. Pins are checked against the footprint pad set and their cited datasheet pages before publish.
  • CAD: KiCad official libraries (CC-BY-SA 4.0).

Datasheet PDF