by John Lauer
Robot-side wireless charging interface board for the Hub Motor Robot: a hardware cold-charge lockout, a pack heater switch, current and voltage supervision, and separate CAN buses for the robot and the charging receiver, on an STM32G0B1. An Adom molecule, routed and checked in KiCad, not built yet.
← Commit history
README, renders, schematic images and review video
17 files changed
+255−4
README.md+128−2images/board-bottom.pngimages/board-iso.pngimages/board-top.pngimages/fields-current.pngimages/fields-heat.pngimages/layout.pngimages/schematic-charge-full.pngimages/schematic-charge.pngimages/schematic-interlock-full.pngimages/schematic-interlock.pngpage.json+9−2videos/fields-review-poster.jpgvideos/fields-review.chapters.json+34videos/fields-review.mp4videos/fields-review.video.json+40videos/fields-review.vtt+44README.md+128−2@@ -1,8 +1,134 @@ # Hub Motor Robot P6: Charge Interface -The robot side of the wireless charger on the [Hub Motor Robot](https://wiki.adom.inc/john/hub-motor-robot). The page is being filled in; renders, schematic images and the review video follow.+The robot side of the wireless charger on the [Hub Motor Robot](https://wiki.adom.inc/john/hub-motor-robot). It sits between the charging receiver (a WiBotic 300 W class unit on the robot's nose) and the 13S battery pack. It decides in hardware whether charging is allowed, warms a cold pack from dock power before charging it, and reports to the robot over CAN. -**Status: designed, not built.** The board is routed and poured and passes KiCad's design rules check. It has not been ordered, assembled or tested.+<img src="images/board-iso.png" alt="The P6 charge interface board, rendered from the KiCad design" width="900">++**Status: designed, not built.** The board is fully routed and poured. KiCad 10.0.5 reports 0 design rule violations and 0 unconnected items on the board, and 0 electrical rule violations on the schematic. No board has been ordered, assembled or powered. Every number on this page comes from the design files, from calculation or from simulation. Nothing has been measured on hardware, and the firmware reference has not been compiled for or flashed to the microcontroller.++## What it does++| | |+|---|---|+| Charge path | Receiver input through a 10 A fuse and a 10 milliohm Kelvin shunt, then an LTC4359 ideal diode controller driving two back to back 100 V MOSFETs (IPD90N10S4L-06). Off by default, and it blocks current in both directions when off |+| Cold charge lockout | Two pack thermistors feed TLV1704 comparators and 74HC21 AND gates. Charging is refused when the pack is too cold (calculated cutoff between 0.6 and 6.8 C) or too hot (51 to 59 C), without any firmware in the loop |+| Pack heater | A 100 V P-channel high side switch with its own 1.25 A fuse runs an external pack heater (about 30 W) from dock power only, so a cold pack can be warmed while the charge path stays off |+| Supervision | Receiver over and under voltage window, an overcurrent trip at 5.4 to 6.0 A (calculated), open and shorted sensor detection, two TPS3823 supervisors and a watchdog. Any fault removes both outputs |+| Controller | STM32G0B1KCT6 with a 40 MHz oscillator for CAN FD timing |+| CAN | Two TCAN3413 transceivers on two separate buses: the robot's CAN FD bus (1 and 5 Mbit/s, no termination on this board) and a classical CAN bus to the charging receiver (120 ohm termination on this board) |+| Logic power | RECOM R-78C3.3-1.0 module, 3.3 V from the robot's 9 to 16 V always-on rail |+| Protection | SMBJ58A TVS diodes on the power nodes and ESD protection on both CAN buses and on the thermistor inputs |+| Optional | An infrared docking beacon driver is drawn and routed but not populated (8 parts) |+| Board | 92 x 60 mm, 4 copper layers (70 / 35 / 35 / 70 um), 1.7 mm, ENIG. An Adom molecule: 34 machine contacts along the two long edges and a grounded machine pin in each corner |++## Top and bottom++<img src="images/board-top.png" alt="Top side of the board" width="800">++All fitted parts are on the top side except one 100 nF capacitor (C28). The square module in the corner is the 3.3 V converter.++<img src="images/board-bottom.png" alt="Bottom side of the board" width="800">++The bare copper areas on the bottom are openings in the solder mask under the charge path. They are meant to sit on a metal pedestal in the robot through an electrically insulating thermal pad, because the openings are at different potentials.++The 3D model in the viewer at the top of this page was built by the wiki from the STEP, board and Gerber files in the Files tab. It shows the populated board, without the 8 optional beacon parts.++## Review video++::adom-video{src="/john/hub-motor-robot-charge/videos/fields-review.video.json"}++A narrated 87 second walk through the board in Adom Fields (current, heat and field views computed from the copper, played at double speed) and then in KiCad's 3D viewer. [Download the video](videos/fields-review.mp4). The original recording was shortened by about 11 seconds and one legend note was covered; the rest is as recorded.++## Current and heat, simulated++<img src="images/fields-heat.png" alt="Heat flow in the top copper layer" width="900">++Heat flow in the top copper with the 6 A charge path on. The hottest parts in the model are the shunt (R60) and the input fuse (F1), at about 15 C above ambient in still air.++<img src="images/fields-current.png" alt="Current density in the copper" width="900">++Current density in the copper. The peak in the model is about 46 A/mm2.++| Result from the model | Value |+|---|---|+| Worst temperature rise on the board, with the pedestal, in a 60 C bay | 17.2 C (design limit 20 C) |+| Highest current density in a conductor | 45.5 A/mm2 |+| Mean current density in the busiest via barrels | 47.3 A/mm2 |+| Return path and decoupling notes raised by the tool | 63 (60 low, 3 medium), reviewed and left as they are |++These are numerical screens of the design files, not thermal or EMC qualification. The pedestal's thermal resistance (2.69 K/W) and the thermal pad (0.5 K/W) are assumptions that have to be measured.++## Layout++<img src="images/layout.png" alt="The routed board in the KiCad PCB editor" width="900">++The routed board in KiCad: 212 footprints, 6710 track segments, 646 vias, 102 nets, 0 unrouted. The wide red areas at the top left are the charge path pours.++## Checks run on these files++Run with KiCad 10.0.5 on the files in this page, on 2026-11-21.++| Check | Result |+|---|---|+| Design rules (DRC), all severities | 0 violations, 0 unconnected items |+| Electrical rules (ERC), all severities, 31 sheets | 0 violations |+| Schematic to board parity | 46 warnings, 0 errors: 29 test points whose "exclude from BOM" flag differs between schematic and board, 6 resistors whose value text differs ("33kp" in the schematic), and 11 unused IC pins that have a no-connect net name in the schematic and no net on the board |+| Wiki model build | Passed: machine pin and contact names, fabrication files, and the STEP placed on the board's machine pins |++The design rules are Adom's 4-layer rules with 0.20 mm minimum track and clearance and wider spacing on the 60 V nets.++## Contacts++| Contacts | Signal |+|---|---|+| MC1 to MC4 | Receiver power in, positive and negative, two contacts each |+| MC5 to MC8 | Charge output to the pack, positive and negative, two contacts each |+| MC9, MC10 | Pack heater |+| MC11 to MC13 | Two pack thermistors and their return |+| MC14, MC15 | 12 V always-on and ground |+| MC16, MC17 | 12 V main (for the optional beacon) and ground |+| MC18 to MC20 | Receiver CAN high, low and ground |+| MC21 to MC25 | Robot CAN FD, in and out pairs, and ground |+| MC26, MC27 | Optional beacon LED |+| MC28 to MC32 | Programming: 3.3 V, SWDIO, SWCLK, reset, ground |+| MC33, MC34 | Receiver ambient thermistor |+| MP1 to MP4 | Corner machine pins, ground |++## Schematic++The schematic is 31 sheets. It was generated from the design netlist, so the parts on each sheet connect by net labels and not by drawn wires, and the sheets still carry a "draft, not for fabrication" stamp. The page's Schematics section shows every sheet. Two of them:++[<img src="images/schematic-charge.png" alt="Charge path sheet" width="800">](images/schematic-charge-full.png)++The charge path: the ideal diode controller, the two MOSFETs and the input fuse.++[<img src="images/schematic-interlock.png" alt="Interlock sheet" width="800">](images/schematic-interlock-full.png)++The interlock: the comparators and gates that decide whether charging and heating are allowed.++## Files++| File | What |+|---|---|+| [hub-motor-robot-charge.kicad_pcb](hub-motor-robot-charge.kicad_pcb) | Board (KiCad 10), routed and poured |+| [hub-motor-robot-charge.kicad_sch](hub-motor-robot-charge.kicad_sch) | Schematic root sheet; the 30 sub-sheets are beside it |+| [hub-motor-robot-charge.kicad_dru](hub-motor-robot-charge.kicad_dru) | Design rules |+| [hub-motor-robot-charge.step](hub-motor-robot-charge.step) | STEP of the populated board, exported from KiCad |+| [hub-motor-robot-charge-fab.zip](hub-motor-robot-charge-fab.zip) | Gerbers for 4 copper layers, mask, paste and silkscreen, plus drill files |+| [export.json](export.json) | Record of the export: tool versions and a hash of every source file |+| [bom.csv](bom.csv) | Bill of materials: 212 references, 35 part numbers, with the distributor stock and price seen on 2026-10-17 |+| [lib/](lib/) | Symbols and footprints for every part on the board |+| [3d/](3d/) | 3D models of the parts that are not in KiCad's own library |++The parts add up to about 84 USD per board at single quantity prices from 2026-10-17. That leaves out the machine contacts and pins, the thermistors, the board itself and assembly.++## Before anyone builds one++- Confirm the stackup with the fabricator: 2 oz outer copper, 1 oz inner copper and the 1.7 mm thickness.+- The machine contacts and pins are fitted after assembly. Leave them and the 8 beacon parts out of the pick and place file.+- Check the rotation of C28 (bottom side) in the fabricator's preview.+- Bring-up has to prove the cold start with the pack disconnected, the temperature thresholds with real sensors, every fault and latch, the current trip, the heater, both CAN buses and the temperature of the pedestal.+- The small fuses on this board do not interrupt a battery short circuit. The robot's power board has to protect this branch. ## License
images/board-bottom.pngadded⋯ 1 unchanged line ⋯
images/board-iso.pngadded⋯ 1 unchanged line ⋯
images/board-top.pngadded⋯ 1 unchanged line ⋯
images/fields-current.pngadded⋯ 1 unchanged line ⋯
images/fields-heat.pngadded⋯ 1 unchanged line ⋯
images/layout.pngadded⋯ 1 unchanged line ⋯
images/schematic-charge-full.pngadded⋯ 1 unchanged line ⋯
images/schematic-charge.pngadded⋯ 1 unchanged line ⋯
images/schematic-interlock-full.pngadded⋯ 1 unchanged line ⋯
images/schematic-interlock.pngadded⋯ 1 unchanged line ⋯
page.json+9−2@@ -21,7 +21,14 @@ "component": { "mpn": "HUB-MOTOR-ROBOT-CHARGE", "manufacturer": "Adom",- "category": "other"+ "category": "other",+ "viewer_3d": {+ "camera": {+ "alpha": 1.571,+ "beta": 0.785,+ "radiusScale": 1.081+ }+ } }, "dependencies": { "adom/0402b103j500ct": "*",@@ -59,4 +66,4 @@ "john/wsl2512r0100fea": "*" }, "visibility": "private"-}+}
videos/fields-review-poster.jpgadded⋯ 1 unchanged line ⋯
videos/fields-review.chapters.jsonadded+34@@ -0,0 +1,34 @@+[+ {+ "t": 0,+ "title": "Fields review"+ },+ {+ "t": 4,+ "title": "Heat flow in the copper"+ },+ {+ "t": 13,+ "title": "Temperature rise and current density"+ },+ {+ "t": 18,+ "title": "Voltage across the layers"+ },+ {+ "t": 23,+ "title": "Energy and signal speed"+ },+ {+ "t": 29,+ "title": "Charge and magnetic field"+ },+ {+ "t": 39,+ "title": "EMC, ground and return paths"+ },+ {+ "t": 65,+ "title": "KiCad 3D view"+ }+]
videos/fields-review.mp4added⋯ 1 unchanged line ⋯
videos/fields-review.video.jsonadded+40@@ -0,0 +1,40 @@+{+ "video": "/john/hub-motor-robot-charge/videos/fields-review.mp4",+ "title": "Adom Fields review of the P6 charge interface",+ "poster": "/john/hub-motor-robot-charge/videos/fields-review-poster.jpg",+ "chapters": [+ {+ "t": 0,+ "title": "Fields review"+ },+ {+ "t": 4,+ "title": "Heat flow in the copper"+ },+ {+ "t": 13,+ "title": "Temperature rise and current density"+ },+ {+ "t": 18,+ "title": "Voltage across the layers"+ },+ {+ "t": 23,+ "title": "Energy and signal speed"+ },+ {+ "t": 29,+ "title": "Charge and magnetic field"+ },+ {+ "t": 39,+ "title": "EMC, ground and return paths"+ },+ {+ "t": 65,+ "title": "KiCad 3D view"+ }+ ],+ "captions": "WEBVTT\n\n00:00:00.300 --> 00:00:05.482\nThis is the Adom Fields review of the P6 charge interface board, at double speed.\n\n00:00:05.800 --> 00:00:09.726\nHeat flow in the top copper with the six amp charge path on.\n\n00:00:09.776 --> 00:00:14.894\nThe shunt and the input fuse run warmest, about fifteen degrees above ambient.\n\n00:00:15.200 --> 00:00:17.056\nCurrent density in the copper.\n\n00:00:17.106 --> 00:00:20.550\nThe peak is about forty six amps per square millimetre.\n\n00:00:20.900 --> 00:00:24.642\nThe layers pulled apart, showing the voltage on every net.\n\n00:00:25.000 --> 00:00:29.534\nEnergy flow between the layers, and how fast a change crosses the board.\n\n00:00:30.000 --> 00:00:36.454\nCharge on the copper, where the board acts as a capacitor, and then the magnetic field around every current.\n\n00:00:39.600 --> 00:00:41.069\nThe return path review.\n\n00:00:41.119 --> 00:00:50.182\nIt lists sixty three notes, sixty low and three medium, mostly signals that run over the three point three volt plane and not over ground.\n\n00:00:53.000 --> 00:00:55.306\nThese are simulations of the design files.\n\n00:00:55.356 --> 00:00:57.942\nNothing here has been measured on a real board.\n\n00:01:06.000 --> 00:01:08.620\nLast, the board in KiCad's 3D viewer.\n\n00:01:08.670 --> 00:01:17.494\nNinety two by sixty millimetres, four layers, with machine contacts along both long edges and a machine pin in each corner.\n\n"+}
videos/fields-review.vttadded+44@@ -0,0 +1,44 @@+WEBVTT++00:00:00.300 --> 00:00:05.482+This is the Adom Fields review of the P6 charge interface board, at double speed.++00:00:05.800 --> 00:00:09.726+Heat flow in the top copper with the six amp charge path on.++00:00:09.776 --> 00:00:14.894+The shunt and the input fuse run warmest, about fifteen degrees above ambient.++00:00:15.200 --> 00:00:17.056+Current density in the copper.++00:00:17.106 --> 00:00:20.550+The peak is about forty six amps per square millimetre.++00:00:20.900 --> 00:00:24.642+The layers pulled apart, showing the voltage on every net.++00:00:25.000 --> 00:00:29.534+Energy flow between the layers, and how fast a change crosses the board.++00:00:30.000 --> 00:00:36.454+Charge on the copper, where the board acts as a capacitor, and then the magnetic field around every current.++00:00:39.600 --> 00:00:41.069+The return path review.++00:00:41.119 --> 00:00:50.182+It lists sixty three notes, sixty low and three medium, mostly signals that run over the three point three volt plane and not over ground.++00:00:53.000 --> 00:00:55.306+These are simulations of the design files.++00:00:55.356 --> 00:00:57.942+Nothing here has been measured on a real board.++00:01:06.000 --> 00:01:08.620+Last, the board in KiCad's 3D viewer.++00:01:08.670 --> 00:01:17.494+Ninety two by sixty millimetres, four layers, with machine contacts along both long edges and a machine pin in each corner.+