← Commit history

Show the released CAD and silkscreen and document fabrication findings

John Lauer ·a398887303 · ·parent 8f7aa9e
3 files changed +3−1
README.md+3−1
@@ -214,7 +214,9 @@ What is not done:  ### Open fabrication findings -The fabrication audit flags via-in-pad on 161 standard SMD pads. Confirm a filled-and-capped via process with the fabricator before ordering. The machine contacts retain their released positions and numbering. +The fabrication audit flags via-in-pad on 161 standard SMD pads. Confirm a filled-and-capped via process with the fabricator before ordering. The machine pins and contacts retain their released positions and numbering. The machine pin numbering follows the released interface and differs from the corner order checked by the current molecule rules.++The saved board has two small 3.3 V corridor zones with no filled polygon. The native connectivity check is clean, and fabrication review still needs to confirm these zones. The automated assembly review also flags 36 footprints without a courtyard, including bare lands and machine hardware.  The board uses the catalog STEP file for each fitted reference. The identification marks on ICs and marked passives represent the order code in CAD. Production marking codes can differ. Some densely grouped references are printed on the opposite face. The silk uses short test-point legends where space permits. Use the test-point table for full net names and the layout for pad locations. 
images/silkscreen-bottom.svg

  
images/silkscreen-top.svg