project
Ghost Hand
Public Unreviewedby John Lauer
A small battery gadget that keeps an automatic sink faucet running while you use the sink: it learns the faucet's timeout, re-arms with the shortest blip, and stops after 10 minutes or when picked up.
← Commit history
aiflow run ghost-hand-claude-opus-5-5-20261108-1620: placement
1 file changed
+13−7
docs/runs/ghost-hand-claude-opus-5-5-20261108-1620/README.md+13−7@@ -1,6 +1,6 @@ # AI Flow run: claude-opus-5-5 on board-0 -**Running**: step `routing`, 78.8 min of AI time since the prompt (119.2 min on the wall clock). This page updates at every step change.+**Running**: step `placement`, 120.3 min of AI time since the prompt (160.7 min on the wall clock). This page updates at every step change. Prompt at 2026-11-08T16:20:00Z (UTC). Flow: board. Every number here is from the run's append-only ledger (run.jsonl). AI time is the time the AI was working on a prompt: from the human's prompt to the AI's done, with any gap over 15 min where no command ran (unobserved, not proven idle) cut out. @@ -10,8 +10,8 @@ One row per human prompt: the AI's time on it, unobserved gaps excluded by the h | Session | Prompt at | Done at | AI time min | Unobserved gap min | What | |---|---|---|---|---|---|-| 1 | 2026-11-08T16:20:00Z | (open) | 78.8 | 40 | the first prompt |-| **all** | | | **78.8** | | |+| 1 | 2026-11-08T16:20:00Z | (open) | 120.3 | 40 | the first prompt |+| **all** | | | **120.3** | | | ## Per step @@ -20,8 +20,8 @@ AI time only, the idle cut out. | Step | AI min | AI thinking min | Tool min | Turns | Visits | Returns | Longest think | |---|---|---|---|---|---|---|---| | intake | 13.2 | 13.2 | 0.0 | 1 | 1 | 0 | 13.1 min |-| placement | 13.7 | 11.0 | 2.6 | 15 | 1 | 0 | 4.9 min |-| routing | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min |+| placement | 13.7 | 11.0 | 2.7 | 16 | 2 | 1 | 4.9 min |+| routing | 41.5 | 9.1 | 32.4 | 13 | 1 | 0 | 4.0 min | | components | 0.1 | 0.1 | 0.0 | 2 | 1 | 0 | 0.1 min | | design | 1.1 | 0.1 | 1.1 | 5 | 1 | 0 | 0.1 min | | library | 0.0 | 0.0 | 0.0 | 1 | 1 | 0 | 0.0 min |@@ -33,7 +33,11 @@ AI time only, the idle cut out. | simulation | 0.1 | 0.0 | 0.1 | 3 | 1 | 0 | 0.0 min | | sourcing | 9.4 | 3.2 | 6.2 | 2 | 1 | 0 | 3.2 min | | test-plan | 26.4 | 25.8 | 0.6 | 5 | 1 | 0 | 13.6 min |-| **total** | **78.8** | **62.4** | **16.3** | | | | |+| **total** | **120.3** | **71.5** | **48.7** | | | | |++## Returns to earlier steps++- 2026-11-08T19:00:43Z back to **placement** (visit 2): U1's bottom-row pins (RX_SIG, LED_DIN) and right-column pins (SDA, VBUS_SENSE) could not escape: U5's top pads sit 1 mm below U1; move U5 1 mm toward the front edge ## Decisions along the way @@ -45,6 +49,7 @@ AI time only, the idle cut out. ## Where the board stands +- routing: 4 unrouted after null passes ## The steps on camera @@ -147,8 +152,9 @@ Percent of each plan limit used, as the provider reports it, at the start of the ## Given back -1 issue(s) or PR(s) filed by this run's AI to make the tool better for every Adom user:+2 issue(s) or PR(s) filed by this run's AI to make the tool better for every Adom user: - issue https://wiki.adom.inc/adom/adom-aiflow/issues/178+- issue https://wiki.adom.inc/adom/adom-aiflow/issues/179 Adom processes PRs within minutes during business hours: a non-stop PR intake runs all day.