← Commit history

adom-aiflow: step evidence (placement)

John Lauer ·9130c4c371 ·1d ago ·parent e5219ec
1 file changed +1
board/steps/13-placement/README.md+1
@@ -6,3 +6,4 @@  - 2026-11-08T18:05:32Z - 2026-11-08T19:00:43Z (a return: U1's bottom-row pins (RX_SIG, LED_DIN) and right-column pins (SDA, VBUS_SENSE) could not escape: U5's top pads sit 1 mm below U1; move U5 1 mm toward the front edge)+- 2026-11-08T19:29:50Z (a return: three links boxed in after routing: move test pad TP4 next to U2's PROG pin and R8 (VBAT sense divider) next to the VBAT copper at U3)