README.md+2@@ -99,4 +99,6 @@ Every step of the build, in order, each with its own page of evidence (checks, s **15. Heatsink vias**: via arrays under the hot parts. [The evidence](steps/15-thermal-vias/README.md) +**16. Copper pours**: copper pours and stitching. [The evidence](steps/16-pours/README.md)+ <!-- /aiflow:steps -->
steps/16-pours/README.mdadded+26@@ -0,0 +1,26 @@+# Step 16: Copper pours++pour every net the spec names, keepouts along Kelvin taps, thermal and stitching vias, land, measure the copper kept++## Visits++- 2026-11-12T18:57:01Z++## What the binary checked++### land-pours++- **adopted**: 0 item(s)+- **after**: B.Cu 4292.14; F.Cu 3746.26+- **before**: +- **coverageAfter**: B.Cu 87.59; F.Cu 76.45+- **failed**: 0 item(s)+- **groups**: 1 item(s)+- **kept**: 0 item(s)+- **leftAlone**: 0 item(s)++## Screenshots and drawings++**start**++
steps/16-pours/shot-pours-1-start.pngadded⋯ 1 unchanged line ⋯