molecule
COSMIIC Pulse Generator Eval Board
Public UnreviewedCOSMIIC PG4 Pulse Generator — AT90CAN128 AVR, 4-channel monopolar stimulation (0–20 mA, 1–255 μs), triple failsafe, CANopen networked. Altium project, Gerbers, STEP, BOM.
← Commit history
Initial commit: component/cosmiic-pulse-generator-eval-board-545000
2 files changed
+122
README.mdadded+84@@ -0,0 +1,84 @@+# COSMIIC Pulse Generator (PG4)++The PG4 is a four-channel implantable pulse generator for electrical stimulation of nerve and muscle tissue. It delivers programmable monopolar stimulation through four independent electrodes, using the device case as the common return path.++## How it works++The PG4 receives stimulation parameters over the CANopen network from the Power Module. Its **Atmel AT90CAN128** processor converts control signals into precise charge-balanced stimulus pulses according to pre-programmed patterns or real-time commands. The SYNC message from the PM controls pulse frequency.++Three independent failsafe mechanisms protect against overstimulation:+1. **Hardware limits** on total charge per pulse+2. **Software limits** on stimulation parameters+3. **Magnetic shutdown switches** in both PG4 and PM++## Hardware++| Parameter | Value |+|-----------|-------|+| Processor | Atmel AT90CAN128 (8-bit AVR) |+| Channels | 4 independent monopolar |+| Pulse Width | 1–255 microseconds |+| Pulse Amplitude | 0–20 mA |+| Inter-Phase Interval | 5–100 μs (default 50) |+| Frequency | 1–50 Hz (via SYNC period) |+| Network | CANopen, 4 ports (1 in + 3 out) |+| Power | Network-powered from PM |+| Case | Titanium with epoxy header |+| Placement | Extremities (upper arm, forearm) |++## Stimulation Modes++- **Direct PM parameter setting** — ~50 Hz update, up to 24 channels+- **SDO direct setting** — ~4 Hz for 12 channels, ~50 Hz single channel (recommended for testing)+- **Pattern-based lookup tables** — preloaded, up to 48 patterns per PG4 (recommended for permanent systems)++## MATLAB Control++```matlab+nnp.networkOn;+nnp.setSync(50); % 50ms = 20 Hz+nnp.enterTestStim;+nnp.write(node, '3212', ch, [PW, PA*10]); % pulse width, amplitude+nnp.write(node, '3212', ch, [0, 0]); % stop+nnp.enterWaiting;+```++## Build++**Source:** [COSMIIC-Community/Implantables-PG4-Hardware](https://github.com/COSMIIC-Community/Implantables-PG4-Hardware) (Aug 2025)++**EDA:** Altium Designer (PcbDoc + SchDoc format)++**Firmware:** [COSMIIC-Community/Implantables-PG4-App](https://github.com/COSMIIC-Community/Implantables-PG4-App) (C, AVR toolchain)++## Source++All design files are open source under CERN-OHL-P-2.0 (hardware) and MIT (firmware).++## Files++| File | Description |+|------|-------------|+| `cosmiic-pg4-altium-project.zip` | Altium project — PcbDoc, PcbLib, 8-page schematic (SchDoc), PrjPCB |+| `cosmiic-pg4-gerbers.zip` | Gerber fabrication files |+| `cosmiic-pg4-schematic.pdf` | Full schematic PDF (8 pages) |+| `cosmiic-pg4-assembly.step` | Complete mechanical assembly STEP (titanium case, headers, capthroughs) |+| `cosmiic-pg4-bom.xlsx` | Bill of Materials (Excel) |++## Altium Project Structure++The Altium project (`PG4D`) contains:+- **PCB layout** (`PG4D.PcbDoc`) + component library (`PG4D.PcbLib`)+- **8-page schematic** covering stimulation DACs, current sources, CAN interface, AVR MCU, safety circuits, and electrode connectors++## NSF Relevance++The PG4 is a four-channel implantable stimulator module capable of delivering programmable monopolar stimulation through four independent electrodes using the device case as the return path. Powered and networked through a single cable, the PG4 incorporates an Atmel AT90CAN128 MCU for precise waveform generation and incorporates triple-layer failsafe protections, including hardware charge limits, software safety checks, and magnetic shutdown control.++## Science Drivers++implantable_healthcare++Created by: adonis+Version: v1+Category: stimulation
page.jsonadded+38@@ -0,0 +1,38 @@+{+ "schema_version": 1,+ "type": "component",+ "slug": "cosmiic-pulse-generator-eval-board-545000",+ "title": "COSMIIC Pulse Generator Eval Board",+ "brief": "COSMIIC PG4 Pulse Generator — AT90CAN128 AVR, 4-channel monopolar stimulation (0–20 mA, 1–255 μs), triple failsafe, CANopen networked. Altium project, Gerbers, STEP, BOM.",+ "version": "1.0.0",+ "tags": [],+ "license": "MIT",+ "component": {+ "mpn": "COSMIIC Pulse Generator Eval Board",+ "manufacturer": "",+ "package": "",+ "pin_count": null,+ "category": "other",+ "subcategory": "",+ "body_size": null,+ "parts": {},+ "distributor_links": {},+ "molecule_id": 1829602329178545000+ },+ "readme": "# COSMIIC Pulse Generator (PG4)\n\nThe PG4 is a four-channel implantable pulse generator for electrical stimulation of nerve and muscle tissue. It delivers programmable monopolar stimulation through four independent electrodes, using the device case as the common return path.\n\n## How it works\n\nThe PG4 receives stimulation parameters over the CANopen network from the Power Module. Its **Atmel AT90CAN128** processor converts control signals into precise charge-balanced stimulus pulses according to pre-programmed patterns or real-time commands. The SYNC message from the PM controls pulse frequency.\n\nThree independent failsafe mechanisms protect against overstimulation:\n1. **Hardware limits** on total charge per pulse\n2. **Software limits** on stimulation parameters\n3. **Magnetic shutdown switches** in both PG4 and PM\n\n## Hardware\n\n| Parameter | Value |\n|-----------|-------|\n| Processor | Atmel AT90CAN128 (8-bit AVR) |\n| Channels | 4 independent monopolar |\n| Pulse Width | 1–255 microseconds |\n| Pulse Amplitude | 0–20 mA |\n| Inter-Phase Interval | 5–100 μs (default 50) |\n| Frequency | 1–50 Hz (via SYNC period) |\n| Network | CANopen, 4 ports (1 in + 3 out) |\n| Power | Network-powered from PM |\n| Case | Titanium with epoxy header |\n| Placement | Extremities (upper arm, forearm) |\n\n## Stimulation Modes\n\n- **Direct PM parameter setting** — ~50 Hz update, up to 24 channels\n- **SDO direct setting** — ~4 Hz for 12 channels, ~50 Hz single channel (recommended for testing)\n- **Pattern-based lookup tables** — preloaded, up to 48 patterns per PG4 (recommended for permanent systems)\n\n## MATLAB Control\n\n```matlab\nnnp.networkOn;\nnnp.setSync(50); % 50ms = 20 Hz\nnnp.enterTestStim;\nnnp.write(node, '3212', ch, [PW, PA*10]); % pulse width, amplitude\nnnp.write(node, '3212', ch, [0, 0]); % stop\nnnp.enterWaiting;\n```\n\n## Build\n\n**Source:** [COSMIIC-Community/Implantables-PG4-Hardware](https://github.com/COSMIIC-Community/Implantables-PG4-Hardware) (Aug 2025)\n\n**EDA:** Altium Designer (PcbDoc + SchDoc format)\n\n**Firmware:** [COSMIIC-Community/Implantables-PG4-App](https://github.com/COSMIIC-Community/Implantables-PG4-App) (C, AVR toolchain)\n\n## Source\n\nAll design files are open source under CERN-OHL-P-2.0 (hardware) and MIT (firmware).\n\n## Files\n\n| File | Description |\n|------|-------------|\n| `cosmiic-pg4-altium-project.zip` | Altium project — PcbDoc, PcbLib, 8-page schematic (SchDoc), PrjPCB |\n| `cosmiic-pg4-gerbers.zip` | Gerber fabrication files |\n| `cosmiic-pg4-schematic.pdf` | Full schematic PDF (8 pages) |\n| `cosmiic-pg4-assembly.step` | Complete mechanical assembly STEP (titanium case, headers, capthroughs) |\n| `cosmiic-pg4-bom.xlsx` | Bill of Materials (Excel) |\n\n## Altium Project Structure\n\nThe Altium project (`PG4D`) contains:\n- **PCB layout** (`PG4D.PcbDoc`) + component library (`PG4D.PcbLib`)\n- **8-page schematic** covering stimulation DACs, current sources, CAN interface, AVR MCU, safety circuits, and electrode connectors\n\n## NSF Relevance\n\nThe PG4 is a four-channel implantable stimulator module capable of delivering programmable monopolar stimulation through four independent electrodes using the device case as the return path. Powered and networked through a single cable, the PG4 incorporates an Atmel AT90CAN128 MCU for precise waveform generation and incorporates triple-layer failsafe protections, including hardware charge limits, software safety checks, and magnetic shutdown control.\n\n## Science Drivers\n\nimplantable_healthcare\n\nCreated by: adonis\nVersion: v1\nCategory: stimulation\n",+ "author": {+ "id": "695820315b5f1e4db2fcf602",+ "name": "Kyle Bergstedt",+ "email": "[email protected]"+ },+ "visibility": {+ "public": true+ },+ "hero": null,+ "sample_prompts": [],+ "discovery_triggers": [],+ "discovery_pitch": null,+ "metadata": {},+ "created_at": "2026-05-28T05:30:52.099Z",+ "updated_at": "2026-05-28T05:30:52.099Z"+}