← Commit history
zxre252asa-7: specified limits as data (metadata.characteristics, 21 rows from the datasheet)
2 files changed
+289
README.md+28@@ -30,6 +30,34 @@ ZXRE252ASA-7 from Diodes Incorporated, in a SOT-23. Pinout and pin descriptions - `ZXRE252ASA-7ZXRE250AW5-7` - `ZXRE252ASA-7ZXRE250BW5-7` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Continuous Cathode Current | IKA | | | 150 | mA | | 2 |+| Cathode Voltage | VKA | | | 40 | V | | 2 |+| Reference Input Current | IREF | -0.05 | | 10 | mA | | 2 |+| Operating Junction Temperature | TJ | | | 150 | °C | | 2 |+| Storage Temperature | TST | -55 | | 150 | °C | | 2 |+| Power Dissipation | PD | | | 330 | mW | SOT23; Notes 5 & 6 | 2 |+| Cathode Current | IKA | 0.065 | | 100 | mA | | 2 |+| Operating Ambient Temperature | TA | -40 | | 125 | °C | | 2 |+| Cathode Voltage (recommended) | VKA | | | 36 | V | | 2 |+| Reference Voltage (ZXRE250A grade, 1%) | VREF | 2.47 | 2.495 | 2.52 | V | VKA = VREF, IKA = 10mA | 2 |+| Deviation of Reference Voltage Over Temperature | VDEV | | 6 | 16 | mV | VKA = VREF, IKA = 10mA, TA = 0 to +70°C | 2 |+| Deviation of Reference Voltage Over Temperature | VDEV | | 14 | 34 | mV | VKA = VREF, IKA = 10mA, TA = -40 to +85°C | 2 |+| Ratio of Change in Reference Voltage to Change in Cathode Voltage | ΔVREF/ΔVKA | | -1.4 | -2.7 | mV/V | IKA = 10mA, VKA = 10V to VREF | 2 |+| Ratio of Change in Reference Voltage to Change in Cathode Voltage | ΔVREF/ΔVKA | | -1 | -2 | mV/V | IKA = 10mA, VKA = 36V to 10V | 2 |+| Reference Input Current | IREF | | 1 | 4 | µA | IKA = 10mA, R1 = 10KΩ, R2 = ∞ | 2 |+| IREF Deviation Over Temperature Range | ΔIREF | | 0.8 | 1.2 | µA | IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = 0 to +70°C | 2 |+| IREF Deviation Over Temperature Range | ΔIREF | | 0.8 | 2.5 | µA | IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = -40 to +85°C | 2 |+| Minimum Cathode Current for Regulation | IKA(MIN) | | 40 | 65 | µA | VKA = VREF | 2 |+| Off-State Current | IKA(OFF) | | 0.05 | 0.5 | µA | VKA = 36V, VREF = 0V | 2 |+| Dynamic Output Impedance | /ZKA/ | | 0.2 | 0.5 | Ω | VKA = VREF, f = 0Hz | 2 |+| Thermal Resistance Junction to Ambient | ϴJA | | 380 | | °C/W | SOT23 | 2 |+ ## CAD (KiCad official) - Symbol: `ZXRE252ASA-7`
page.json+261@@ -133,5 +133,266 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]+ },+ "metadata": {+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": null,+ "rows": [+ {+ "name": "Continuous Cathode Current",+ "symbol": "IKA",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Voltage",+ "symbol": "VKA",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current",+ "symbol": "IREF",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -0.05,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "TST",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation",+ "symbol": "PD",+ "kind": "absolute_maximum",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 330,+ "conditions": "SOT23; Notes 5 & 6",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Current",+ "symbol": "IKA",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 0.065,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Ambient Temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Voltage (recommended)",+ "symbol": "VKA",+ "kind": "recommended_operating",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 36,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (ZXRE250A grade, 1%)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 2.47,+ "typ": 2.495,+ "max": 2.52,+ "conditions": "VKA = VREF, IKA = 10mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Temperature",+ "symbol": "VDEV",+ "kind": "tolerance",+ "unit": "mV",+ "min": null,+ "typ": 6,+ "max": 16,+ "conditions": "VKA = VREF, IKA = 10mA, TA = 0 to +70°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Temperature",+ "symbol": "VDEV",+ "kind": "tolerance",+ "unit": "mV",+ "min": null,+ "typ": 14,+ "max": 34,+ "conditions": "VKA = VREF, IKA = 10mA, TA = -40 to +85°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "voltage_coefficient",+ "unit": "mV/V",+ "min": null,+ "typ": -1.4,+ "max": -2.7,+ "conditions": "IKA = 10mA, VKA = 10V to VREF",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "voltage_coefficient",+ "unit": "mV/V",+ "min": null,+ "typ": -1,+ "max": -2,+ "conditions": "IKA = 10mA, VKA = 36V to 10V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current",+ "symbol": "IREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 1,+ "max": 4,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Temperature Range",+ "symbol": "ΔIREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.8,+ "max": 1.2,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = 0 to +70°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Temperature Range",+ "symbol": "ΔIREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.8,+ "max": 2.5,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = -40 to +85°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum Cathode Current for Regulation",+ "symbol": "IKA(MIN)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 40,+ "max": 65,+ "conditions": "VKA = VREF",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Off-State Current",+ "symbol": "IKA(OFF)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.05,+ "max": 0.5,+ "conditions": "VKA = 36V, VREF = 0V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Dynamic Output Impedance",+ "symbol": "|ZKA|",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.2,+ "max": 0.5,+ "conditions": "VKA = VREF, f = 0Hz",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance Junction to Ambient",+ "symbol": "ϴJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 380,+ "max": null,+ "conditions": "SOT23",+ "source_page": 2,+ "source": "datasheet"+ }+ ]+ } } }