← Commit history
package.json+376−4@@ -1,6 +1,6 @@ { "slug": "zxre252asa-7",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Diodes Incorporated Voltage Reference, SOT-23. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -24,6 +24,378 @@ "docs/hero.png", "docs/zxre252asa-7-datasheet.pdf", "viewers/symbol.html",- "viewers/footprint.html"- ]-}+ "viewers/footprint.html",+ "zxre252asa-7-etched.step",+ "zxre252asa-7-etched.glb"+ ],+ "component": {+ "mpn": "ZXRE252ASA-7",+ "manufacturer": "Diodes Incorporated",+ "package": "SOT-23",+ "pin_count": 3,+ "category": "Voltage Reference",+ "parts": {+ "symbol": "zxre252asa-7.kicad_sym",+ "footprint": "zxre252asa-7.kicad_mod",+ "model_3d": "zxre252asa-7-etched.glb",+ "model_3d_plain": "zxre252asa-7.glb",+ "model_3d_step": "zxre252asa-7-etched.step",+ "model_3d_step_plain": "zxre252asa-7.step",+ "lbr": "zxre252asa-7.lbr"+ },+ "pins": [+ {+ "number": "1",+ "name": "ANODE",+ "type": "power_in",+ "description": "Anode terminal - the reference/return node for the shunt regulator. All specified voltages (VKA, VREF) are measured relative to this pin. Typically tied to the low-side rail (system ground) in a shunt-regulator topology."+ },+ {+ "number": "2",+ "name": "REF",+ "type": "input",+ "description": "Reference input to the internal error amplifier. The device servos the cathode current so that V(REF)-V(ANODE) equals the internal bandgap reference (2.495V typ). Reference input current is 1µA typ (4µA max); tie directly to CATHODE for VKA = VREF, or to the tap of an R1/R2 divider from CATHODE to ANODE to program VOUT = (1 + R1/R2)·VREF up to 36V."+ },+ {+ "number": "3",+ "name": "CATHODE",+ "type": "power_in",+ "description": "Cathode terminal - the regulated shunt node that sinks current from the supply through a series resistor to hold the programmed voltage. Rated VKA up to 40V absolute max (36V recommended), IKA 0.065mA to 100mA operating (150mA absolute max). Dynamic output impedance is 0.2Ω typ; off-state leakage is 0.05µA typ at VKA = 36V."+ }+ ],+ "provenance": {+ "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction",+ "cad": "KiCad official (CC-BY-SA 4.0)",+ "cad_basis": {+ "from": [+ "README CAD section (factory cad_wording)",+ ".kicad_mod model path agrees"+ ],+ "missing": []+ }+ },+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ },+ "distributor_links": {+ "lcsc": "C460471",+ "digikey": "ZXRE252ASA-7DITR-ND",+ "mouser": "621-ZXRE252ASA-7"+ },+ "distributor_check": {+ "checked_at": "2026-10-05T19:27:27Z",+ "source": "Component Ocean /api/assign-pns + lcsc_map",+ "digikey": {+ "pn": "ZXRE252ASA-7DITR-ND",+ "status": "found"+ },+ "mouser": {+ "pn": "621-ZXRE252ASA-7",+ "status": "found"+ }+ },+ "models_3d": [+ {+ "file": "zxre252asa-7.step",+ "role": "plain",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 2.5,+ 3,+ 1.2+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "dd5d1711204e1d8d26cd11490923bd84340820baa69538c385a4300ec2539bc0",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ },+ {+ "file": "zxre252asa-7-etched.step",+ "role": "eda",+ "up": "Z",+ "units": "mm",+ "origin": "footprint origin = pad-pattern centre",+ "seat": "z = 0",+ "extents_mm": [+ 2.5,+ 3,+ 1.2+ ],+ "zmin_mm": 0,+ "centre_offset_mm": 0,+ "footprint_binding": "identity",+ "sha256": "76d73a1beea8a7fca475a56c8b47489b5a6e319f77c79da8b99d074683f485c5",+ "checked": "2026-10-07",+ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)"+ }+ ]+ },+ "metadata": {+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": null,+ "rows": [+ {+ "name": "Continuous Cathode Current",+ "symbol": "IKA",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Voltage",+ "symbol": "VKA",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 40,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current",+ "symbol": "IREF",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -0.05,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Junction Temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "TST",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Power Dissipation",+ "symbol": "PD",+ "kind": "absolute_maximum",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 330,+ "conditions": "SOT23; Notes 5 & 6",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Current",+ "symbol": "IKA",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 0.065,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Ambient Temperature",+ "symbol": "TA",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Cathode Voltage (recommended)",+ "symbol": "VKA",+ "kind": "recommended_operating",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 36,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Voltage (ZXRE250A grade, 1%)",+ "symbol": "VREF",+ "kind": "electrical",+ "unit": "V",+ "min": 2.47,+ "typ": 2.495,+ "max": 2.52,+ "conditions": "VKA = VREF, IKA = 10mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Temperature",+ "symbol": "VDEV",+ "kind": "tolerance",+ "unit": "mV",+ "min": null,+ "typ": 6,+ "max": 16,+ "conditions": "VKA = VREF, IKA = 10mA, TA = 0 to +70°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Deviation of Reference Voltage Over Temperature",+ "symbol": "VDEV",+ "kind": "tolerance",+ "unit": "mV",+ "min": null,+ "typ": 14,+ "max": 34,+ "conditions": "VKA = VREF, IKA = 10mA, TA = -40 to +85°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "voltage_coefficient",+ "unit": "mV/V",+ "min": null,+ "typ": -1.4,+ "max": -2.7,+ "conditions": "IKA = 10mA, VKA = 10V to VREF",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Ratio of Change in Reference Voltage to Change in Cathode Voltage",+ "symbol": "ΔVREF/ΔVKA",+ "kind": "voltage_coefficient",+ "unit": "mV/V",+ "min": null,+ "typ": -1,+ "max": -2,+ "conditions": "IKA = 10mA, VKA = 36V to 10V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reference Input Current",+ "symbol": "IREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 1,+ "max": 4,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Temperature Range",+ "symbol": "ΔIREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.8,+ "max": 1.2,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = 0 to +70°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "IREF Deviation Over Temperature Range",+ "symbol": "ΔIREF",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.8,+ "max": 2.5,+ "conditions": "IKA = 10mA, R1 = 10KΩ, R2 = ∞, TA = -40 to +85°C",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum Cathode Current for Regulation",+ "symbol": "IKA(MIN)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 40,+ "max": 65,+ "conditions": "VKA = VREF",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Off-State Current",+ "symbol": "IKA(OFF)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.05,+ "max": 0.5,+ "conditions": "VKA = 36V, VREF = 0V",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Dynamic Output Impedance",+ "symbol": "|ZKA|",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.2,+ "max": 0.5,+ "conditions": "VKA = VREF, f = 0Hz",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance Junction to Ambient",+ "symbol": "ϴJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 380,+ "max": null,+ "conditions": "SOT23",+ "source_page": 2,+ "source": "datasheet"+ }+ ]+ }+ },+ "visibility": "public"+}
page.json+7−7@@ -1,6 +1,6 @@ { "slug": "zxre252asa-7",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Diodes Incorporated Voltage Reference, SOT-23. Datasheet-verified pinout, KiCad symbol/footprint/3D.", "tags": [@@ -25,11 +25,10 @@ "docs/zxre252asa-7-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html",- "zxre252asa-7-etched.step"+ "zxre252asa-7-etched.step",+ "zxre252asa-7-etched.glb" ],- "visibility": {- "public": true- },+ "visibility": "public", "author": { "name": "Ray" },@@ -401,5 +400,6 @@ } ] }- }-}+ },+ "org": "adom"+}