← Commit history
xl385-1-2: specified limits as data (metadata.characteristics, 10 rows from the datasheet)
2 files changed
+144
README.md+17@@ -27,6 +27,23 @@ The extractor listed these alongside XL385-1.2, but they are **different parts** - `XL385-1.2M3` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Minimum Operating Current (tested limit) | IR(min) | | 8 | 10 | μA | | 2 |+| Minimum Operating Current (design limit) | IR(min) | | 8 | 15 | μA | | 2 |+| Reverse Breakdown Voltage Change with Current (10μA to 1mA) | ΔVR | | 1 | 1.5 | mV | 10μA ≤ IR ≤ 1mA | 2 |+| Reverse Breakdown Voltage Change with Current (1mA to 20mA, tested limit) | ΔVR | | 10 | 20 | mV | 1mA ≤ IR ≤ 20mA | 2 |+| Reverse Breakdown Voltage Change with Current (1mA to 20mA, design limit) | ΔVR | | 10 | 25 | mV | 1mA ≤ IR ≤ 20mA | 2 |+| Average Temperature Coefficient (All Others suffix column) | TC | | | 150 | ppm/°C | IR = 100μA | 2 |+| Operating current range (minimum) | IR | 10 | | | μA | | 1 |+| Operating current range (maximum) | IR | | | 20 | mA | | 1 |+| Operating temperature range | | -40 | | 85 | °C | Ordering table temperature range for XL385-1.2 | 11 |+| Thermal Resistance junction to ambient (SOP) | θJA | | 165 | | °C/W | SOP column | 2 |+ ## CAD (KiCad official) - Symbol: `XL385-1.2`
page.json+127@@ -116,6 +116,133 @@ "Package": "SOP-8", "Category": "PMIC", "Pins": "3"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "8409d80bd41e2abd",+ "rows": [+ {+ "name": "Minimum Operating Current (tested limit)",+ "symbol": "IR(min)",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 8,+ "max": 10,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Minimum Operating Current (design limit)",+ "symbol": "IR(min)",+ "kind": "electrical",+ "unit": "μA",+ "min": null,+ "typ": 8,+ "max": 15,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Breakdown Voltage Change with Current (10μA to 1mA)",+ "symbol": "ΔVR",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 1,+ "max": 1.5,+ "conditions": "10μA ≤ IR ≤ 1mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Breakdown Voltage Change with Current (1mA to 20mA, tested limit)",+ "symbol": "ΔVR",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 10,+ "max": 20,+ "conditions": "1mA ≤ IR ≤ 20mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Breakdown Voltage Change with Current (1mA to 20mA, design limit)",+ "symbol": "ΔVR",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 10,+ "max": 25,+ "conditions": "1mA ≤ IR ≤ 20mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Average Temperature Coefficient (All Others suffix column)",+ "symbol": "TC",+ "kind": "temperature_coefficient",+ "unit": "ppm/°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "IR = 100μA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating current range (minimum)",+ "symbol": "IR",+ "kind": "recommended_operating",+ "unit": "μA",+ "min": 10,+ "typ": null,+ "max": null,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating current range (maximum)",+ "symbol": "IR",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 20,+ "conditions": "",+ "source_page": 1,+ "source": "datasheet"+ },+ {+ "name": "Operating temperature range",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 85,+ "conditions": "Ordering table temperature range for XL385-1.2",+ "source_page": 11,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance junction to ambient (SOP)",+ "symbol": "θJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 165,+ "max": null,+ "conditions": "SOP column",+ "source_page": 2,+ "source": "datasheet"+ }+ ] } }, "variants": [