← Commit history
xl336-2-5: specified limits as data (metadata.characteristics, 14 rows from the datasheet)
2 files changed
+196
README.md+21@@ -39,6 +39,27 @@ The extractor listed these alongside XL336-2.5, but they are **different parts** - `XL336-2.5XL236-2.5` - `XL336-2.5XT336-2.5` +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Reverse Breakdown Voltage | | 2.44 | 2.49 | 2.54 | V | TA=25˚C, IR=1 mA | 2 |+| Reverse Breakdown Change With Current | | | 2.6 | 6 | mV | TA=25˚C, 400 µA≤IR≤10 mA | 2 |+| Reverse Dynamic Impedance | | | 0.2 | 0.6 | Ω | TA=25˚C, IR=1 mA, f = 100 Hz | 2 |+| Reverse Breakdown Change With Current (second row) | | | 3 | 10 | mV | 400 µA≤IR≤10 mA | 2 |+| Reverse Dynamic Impedance (second row) | | | 0.4 | 1 | Ω | IR=1 mA | 2 |+| Long Term Stability | | | 20 | | ppm | TA=25˚C ±0.1˚C, IR=1 mA, t = 1000 hrs | 2 |+| Reverse Current | | | | 15 | mA | | 2 |+| Forward Current | | | | 10 | mA | | 2 |+| Storage Temperature | | -60 | | 150 | ˚C | | 2 |+| Operating Temperature Range (XL336) | | -25 | | 85 | ˚C | XL336 | 2 |+| Maximum Junction Temperature for elevated temperature operation (XL336) | Tj | | | 125 | ˚C | Elevated temperature operation (Note 2) | 2 |+| Soldering Temperature, Vapor Phase (SO package) | | | | 215 | ˚C | SO package, vapor phase, 60 sec | 2 |+| Soldering Temperature, Infrared (SO package) | | | | 220 | ˚C | SO package, infrared, 15 sec | 2 |+| Thermal Resistance, Junction to Ambient (SO-8) | θja | | 165 | | ˚C/W | SO-8 package | 2 |+ ## CAD (KiCad official) - Symbol: `XL336-2.5`
page.json+175@@ -146,6 +146,181 @@ "Package": "SOP-8", "Category": "PMIC", "Pins": "8"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "539676def50beddd",+ "rows": [+ {+ "name": "Reverse Breakdown Voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 2.44,+ "typ": 2.49,+ "max": 2.54,+ "conditions": "TA=25˚C, IR=1 mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Breakdown Change With Current",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 2.6,+ "max": 6,+ "conditions": "TA=25˚C, 400 µA≤IR≤10 mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Dynamic Impedance",+ "symbol": "",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.2,+ "max": 0.6,+ "conditions": "TA=25˚C, IR=1 mA, f = 100 Hz",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Breakdown Change With Current (second row)",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 3,+ "max": 10,+ "conditions": "400 µA≤IR≤10 mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Dynamic Impedance (second row)",+ "symbol": "",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 0.4,+ "max": 1,+ "conditions": "IR=1 mA",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Long Term Stability",+ "symbol": "",+ "kind": "electrical",+ "unit": "ppm",+ "min": null,+ "typ": 20,+ "max": null,+ "conditions": "TA=25˚C ±0.1˚C, IR=1 mA, t = 1000 hrs",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Reverse Current",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 15,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Forward Current",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Storage Temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "˚C",+ "min": -60,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Operating Temperature Range (XL336)",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "˚C",+ "min": -25,+ "typ": null,+ "max": 85,+ "conditions": "XL336",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Maximum Junction Temperature for elevated temperature operation (XL336)",+ "symbol": "Tj",+ "kind": "thermal",+ "unit": "˚C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "Elevated temperature operation (Note 2)",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Soldering Temperature, Vapor Phase (SO package)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "˚C",+ "min": null,+ "typ": null,+ "max": 215,+ "conditions": "SO package, vapor phase, 60 sec",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Soldering Temperature, Infrared (SO package)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "˚C",+ "min": null,+ "typ": null,+ "max": 220,+ "conditions": "SO package, infrared, 15 sec",+ "source_page": 2,+ "source": "datasheet"+ },+ {+ "name": "Thermal Resistance, Junction to Ambient (SO-8)",+ "symbol": "θja",+ "kind": "thermal",+ "unit": "˚C/W",+ "min": null,+ "typ": 165,+ "max": null,+ "conditions": "SO-8 package",+ "source_page": 2,+ "source": "datasheet"+ }+ ] } }, "variants": [