← Commit history

x00602ma-5al2: specified limits as data (metadata.characteristics, 24 rows from the datasheet)

Ray ·41d6cd7261 · ·parent 0417e51
2 files changed +327−1
README.md+31
@@ -21,6 +21,37 @@ X00602MA 5AL2 from STMicroelectronics, in a TO-92. Pinout and pin descriptions e | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Non repetitive surge peak on-state current, tp = 8.3 ms | ITSM |  |  | 10 | A | Tj initial = 25 °C; tp = 8.3 ms; Tj = 25 °C | 2 |+| Non repetitive surge peak on-state current, tp = 10 ms | ITSM |  |  | 9 | A | Tj initial = 25 °C; tp = 10 ms; Tj = 25 °C | 2 |+| Storage junction temperature range | Tstg | -40 |  | 150 | °C |  | 2 |+| Operating junction temperature range | Tj | -40 |  | 125 | °C |  | 2 |+| Gate trigger current | IGT | 15 |  | 200 | µA | VD = 12 V, RL = 140 Ω | 2 |+| Gate trigger voltage | VGT |  |  | 0.8 | V |  | 2 |+| Non-triggering gate voltage | VGD | 0.2 |  |  | V | VD = VDRM, RL = 3.3 kΩ, RGK = 1 kΩ, Tj = 125 °C | 2 |+| Reverse gate voltage | VRG | 5 |  |  |  | IRG = 10 µA | 2 |+| Holding current | IH |  |  | 5 | mA | IT = 50 mA, RGK = 1 kΩ | 2 |+| Latching current | IL |  |  | 6 | mA | IG = 1 mA, RGK = 1 kΩ | 2 |+| Critical rate of rise of off-state voltage | dV/dt | 25 |  |  | V/µs | VD = 67 % VDRM, RGK = 1 kΩ, Tj = 125 °C | 2 |+| On-state voltage | VTM |  |  | 1.35 | V | ITM = 1 A, tp = 380 µs, 25 °C | 2 |+| Threshold on-state voltage | VTO |  |  | 0.85 | V | 125 °C | 2 |+| Dynamic resistance | Rd |  |  | 245 | mΩ | 125 °C | 2 |+| Repetitive peak off-state current (IDRM/IRRM) | IDRM/IRRM |  |  | 1 | µA | VDRM = VRRM, RGK = 1 kΩ, 25 °C | 2 |+| Repetitive peak off-state current (IDRM/IRRM) | IDRM/IRRM |  |  | 100 | µA | VDRM = VRRM, RGK = 1 kΩ, 125 °C | 2 |+| On-state RMS current (180° conduction angle), TO-92 | IT(RMS) |  |  | 0.8 | A | TL = 83 °C | 2 |+| Average on-state current (180° conduction angle), TO-92 | IT(AV) |  |  | 0.5 | A | TL = 83 °C | 2 |+| I2t value for fusing | I2t |  |  | 0.4 | A2s | tp = 10 ms; Tj = 25 °C | 2 |+| Critical rate of rise of on-state current | dI/dt |  |  | 50 | A/µs | IG = 2 x IGT, tr ≤ 100 ns, F = 60 Hz, Tj = 125 °C | 2 |+| Peak gate current | IGM |  |  | 1 | A | tp = 20 µs, Tj = 125 °C | 2 |+| Average gate power dissipation | PG(AV) |  |  | 0.1 | W | Tj = 125 °C | 2 |+| Junction to leads (DC), TO-92 | Rth(j-l) |  |  | 70 | °C/W |  | 2 |+| Junction to ambient (DC), TO-92 | Rth(j-a) |  |  | 150 | °C/W |  | 2 |+ ## CAD (KiCad official)  - Symbol: `X00602MA 5AL2`
page.json+296−1
@@ -151,6 +151,301 @@       "Package": "TO-92",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "f3ea692d4cb40600",+      "rows": [+        {+          "name": "Non repetitive surge peak on-state current, tp = 8.3 ms",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 10,+          "conditions": "Tj initial = 25 °C; tp = 8.3 ms; Tj = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non repetitive surge peak on-state current, tp = 10 ms",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 9,+          "conditions": "Tj initial = 25 °C; tp = 10 ms; Tj = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage junction temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Operating junction temperature range",+          "symbol": "Tj",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate trigger current",+          "symbol": "IGT",+          "kind": "electrical",+          "unit": "µA",+          "min": 15,+          "typ": null,+          "max": 200,+          "conditions": "VD = 12 V, RL = 140 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate trigger voltage",+          "symbol": "VGT",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non-triggering gate voltage",+          "symbol": "VGD",+          "kind": "electrical",+          "unit": "V",+          "min": 0.2,+          "typ": null,+          "max": null,+          "conditions": "VD = VDRM, RL = 3.3 kΩ, RGK = 1 kΩ, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Reverse gate voltage",+          "symbol": "VRG",+          "kind": "electrical",+          "unit": "",+          "min": 5,+          "typ": null,+          "max": null,+          "conditions": "IRG = 10 µA",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Holding current",+          "symbol": "IH",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "IT = 50 mA, RGK = 1 kΩ",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Latching current",+          "symbol": "IL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 6,+          "conditions": "IG = 1 mA, RGK = 1 kΩ",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of off-state voltage",+          "symbol": "dV/dt",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 25,+          "typ": null,+          "max": null,+          "conditions": "VD = 67 % VDRM, RGK = 1 kΩ, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "On-state voltage",+          "symbol": "VTM",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.35,+          "conditions": "ITM = 1 A, tp = 380 µs, 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Threshold on-state voltage",+          "symbol": "VTO",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.85,+          "conditions": "125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Dynamic resistance",+          "symbol": "Rd",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 245,+          "conditions": "125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Repetitive peak off-state current (IDRM/IRRM)",+          "symbol": "IDRM/IRRM",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "VDRM = VRRM, RGK = 1 kΩ, 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Repetitive peak off-state current (IDRM/IRRM)",+          "symbol": "IDRM/IRRM",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "VDRM = VRRM, RGK = 1 kΩ, 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "On-state RMS current (180° conduction angle), TO-92",+          "symbol": "IT(RMS)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.8,+          "conditions": "TL = 83 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average on-state current (180° conduction angle), TO-92",+          "symbol": "IT(AV)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 0.5,+          "conditions": "TL = 83 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "I2t value for fusing",+          "symbol": "I2t",+          "kind": "absolute_maximum",+          "unit": "A2s",+          "min": null,+          "typ": null,+          "max": 0.4,+          "conditions": "tp = 10 ms; Tj = 25 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of on-state current",+          "symbol": "dI/dt",+          "kind": "absolute_maximum",+          "unit": "A/µs",+          "min": null,+          "typ": null,+          "max": 50,+          "conditions": "IG = 2 x IGT, tr ≤ 100 ns, F = 60 Hz, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Peak gate current",+          "symbol": "IGM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "tp = 20 µs, Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average gate power dissipation",+          "symbol": "PG(AV)",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.1,+          "conditions": "Tj = 125 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction to leads (DC), TO-92",+          "symbol": "Rth(j-l)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 70,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Junction to ambient (DC), TO-92",+          "symbol": "Rth(j-a)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -192,4 +487,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}