← Commit history

wip252010p-r22ml: specified limits as data (metadata.characteristics, 8 rows from the datasheet)

Ray ·eedabe14ba · ·parent ee4f910
2 files changed +119−1
README.md+15
@@ -20,6 +20,21 @@ WIP252010P-R22ML from INPAQ, in a 1008. Pinout and pin descriptions extracted fr | Category | Inductors, Coils, Chokes | | Pins | 2 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| DC resistance (typical) | RDC |  | 9 | 12.5 | mΩ | Measured with HIOKI RM3542-01 micro-ohm meter (Note 5); typical and maximum as printed for WIP252010P-R22ML | 4 |+| Heat rating current | Irms |  | 7.9 | 7.2 | A | DC current causing coil temp. rise of 40℃, whichever is smaller (Note 7); test at 26℃ ambient (Note 2) | 4 |+| Saturation current | Isat |  | 5.9 | 5.3 | A | DC current causing 30% inductance reduction from initial value (Note 6); test at 26℃ ambient (Note 2) | 4 |+| Initial inductance | Li | -20 |  | 20 | % | Inductance tolerance ±20% (Note 3) | 4 |+| Initial inductance (nominal) | Li |  | 0.22 |  | μH | @1mA; measured at 1 MHz with Agilent 4285A LCR meter (Notes 2, 4) | 4 |+| Operating temperature range |  | -40 |  | 125 | ℃ | Operating temperature range (see Note 7 in 5.1) | 3 |+| Storage temperature range |  | -50 |  | 125 | ℃ | Storage temperature range | 3 |+| Taping package storage temperature |  | 5 |  | 40 | ℃ | Taping package storage condition; relative humidity <65%RH; storage time 12 months max | 9 |+ ## CAD (KiCad official)  - Symbol: `WIP252010P-R22ML`
page.json+104−1
@@ -141,6 +141,109 @@       "Package": "1008",       "Category": "Inductors, Coils, Chokes",       "Pins": "2"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "7d7fce1cd6156a78",+      "rows": [+        {+          "name": "DC resistance (typical)",+          "symbol": "RDC",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": 9,+          "max": 12.5,+          "conditions": "Measured with HIOKI RM3542-01 micro-ohm meter (Note 5); typical and maximum as printed for WIP252010P-R22ML",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Heat rating current",+          "symbol": "Irms",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 7.9,+          "max": 7.2,+          "conditions": "DC current causing coil temp. rise of 40℃, whichever is smaller (Note 7); test at 26℃ ambient (Note 2)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Saturation current",+          "symbol": "Isat",+          "kind": "electrical",+          "unit": "A",+          "min": null,+          "typ": 5.9,+          "max": 5.3,+          "conditions": "DC current causing 30% inductance reduction from initial value (Note 6); test at 26℃ ambient (Note 2)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Initial inductance",+          "symbol": "Li",+          "kind": "tolerance",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "Inductance tolerance ±20% (Note 3)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Initial inductance (nominal)",+          "symbol": "Li",+          "kind": "electrical",+          "unit": "μH",+          "min": null,+          "typ": 0.22,+          "max": null,+          "conditions": "@1mA; measured at 1 MHz with Agilent 4285A LCR meter (Notes 2, 4)",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": -40,+          "typ": null,+          "max": 125,+          "conditions": "Operating temperature range (see Note 7 in 5.1)",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature range",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃",+          "min": -50,+          "typ": null,+          "max": 125,+          "conditions": "Storage temperature range",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Taping package storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": 5,+          "typ": null,+          "max": 40,+          "conditions": "Taping package storage condition; relative humidity <65%RH; storage time 12 months max",+          "source_page": 9,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -183,4 +286,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}