← Commit history

Publish 0.1.1

Ray ·b9a2e4dff7 · ·parent 9061ce5
4 files changed +372−14
package.json+363−4
@@ -1,6 +1,6 @@ {   "slug": "vhf201209h3n3st",-  "version": "0.1.0",+  "version": "0.1.1",   "type": "component",   "description": "FH Guangdong Fenghua Advanced Tech Inductors (SMD), 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",   "tags": [@@ -28,8 +28,7 @@     "viewers/symbol.html",     "viewers/footprint.html",     "vhf201209h3n3st-hero.glb",-    "vhf201209h3n3st-hero.overlay.json",-    "vhf201209h3n3st-etched.glb"+    "vhf201209h3n3st-hero.overlay.json"   ],   "component": {     "mpn": "VHF201209H3N3ST",@@ -154,10 +153,363 @@     ]   },   "metadata": {+    "specs": {+      "Manufacturer": "FH Guangdong Fenghua Advanced Tech",+      "Package": "0805",+      "Category": "Inductors, Coils, Chokes",+      "Pins": "2"+    },+    "appearance": {+      "contacts": {+        "quote": "Terminal electrode 银层 Ag layer 银Ag",+        "page": 4,+        "doc": "ds.pdf",+        "plating": "silver"+      },+      "version": 1,+      "datasheet_sha256": "50796b7be5acd3b5fdfed0f109c9fb5a3bcad351bb3f7a9c0862a0defa417490"+    },     "characteristics": {       "version": 1,       "source": "datasheet",+      "datasheet_sha256": "50796b7be5acd3b5fdfed0f109c9fb5a3bcad351bb3f7a9c0862a0defa417490",       "rows": [+        {+          "name": "Inductance tolerance (suffix S)",+          "symbol": "",+          "kind": "tolerance",+          "unit": "nH",+          "min": -0.3,+          "typ": null,+          "max": 0.3,+          "conditions": "Suffix S level; Ls<6.8nH",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Q value (min)",+          "symbol": "",+          "kind": "electrical",+          "unit": "",+          "min": 12,+          "typ": null,+          "max": null,+          "conditions": "Test frequency 100 MHz; test voltage 50 mV",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DC resistance (RDC)",+          "symbol": "RDC",+          "kind": "electrical",+          "unit": "Ω",+          "min": null,+          "typ": null,+          "max": 0.13,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Self-resonant frequency (SRF)",+          "symbol": "SRF",+          "kind": "electrical",+          "unit": "MHz",+          "min": 5000,+          "typ": null,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Rated current",+          "symbol": "",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 500,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after resistance to soldering heat",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "Ceramic (H) material; dip 260±5℃, 10±1 s",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Q value change after resistance to soldering heat (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "Dip 260±5℃, 10±1 s",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after low temperature resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "-40±2℃, 1000 +24/-0 h",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Q value change after low temperature resistance (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "-40±2℃, 1000 +24/-0 h",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after vibration",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "10–55–10 Hz, amplitude 1.5 mm, 2 h per each of 3 directions",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Q value change after vibration (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "10–55–10 Hz, amplitude 1.5 mm, 2 h per each of 3 directions",+          "source_page": 8,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after high temperature resistance",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "85±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Q value change after high temperature resistance (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "85±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after static humidity test",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "90–95% RH, 60±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Q value change after static humidity test (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "90–95% RH, 60±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after high temperature load",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "Rated current applied, 85±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Q value change after high temperature load (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "Rated current applied, 85±2℃, 1000 +24/-0 h",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Inductance change after temperature shock",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -10,+          "typ": null,+          "max": 10,+          "conditions": "-55℃ / +125℃, 30±3 min each, 100 cycles",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Q value change after temperature shock (ceramic)",+          "symbol": "",+          "kind": "electrical",+          "unit": "%",+          "min": -20,+          "typ": null,+          "max": 20,+          "conditions": "-55℃ / +125℃, 30±3 min each, 100 cycles",+          "source_page": 9,+          "source": "datasheet"+        },+        {+          "name": "Operating temperature range",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 7,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "℃",+          "min": -10,+          "typ": null,+          "max": 40,+          "conditions": "Warehouse storage",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Storage relative humidity",+          "symbol": "",+          "kind": "recommended_operating",+          "unit": "%",+          "min": 30,+          "typ": null,+          "max": 70,+          "conditions": "Warehouse storage",+          "source_page": 13,+          "source": "datasheet"+        },+        {+          "name": "Preheat temperature difference between product surface and solder",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "Reflow preheating",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Temperature difference between product and solvent after soldering",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "Cooling into solvent after soldering",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Iron soldering temperature",+          "symbol": "",+          "kind": "thermal",+          "unit": "℃",+          "min": null,+          "typ": null,+          "max": 350,+          "conditions": "Hand soldering",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Iron soldering power",+          "symbol": "",+          "kind": "thermal",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 30,+          "conditions": "Hand soldering",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Iron soldering time",+          "symbol": "",+          "kind": "thermal",+          "unit": "s",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "Hand soldering; do not touch terminal electrodes with tip",+          "source_page": 12,+          "source": "datasheet"+        },+        {+          "name": "Nominal inductance",+          "symbol": "",+          "kind": "electrical",+          "unit": "nH",+          "min": null,+          "typ": 3.3,+          "max": null,+          "conditions": "",+          "source_page": 5,+          "source": "datasheet"+        },         {           "kind": "nominal",           "name": "Inductance",@@ -220,5 +572,12 @@         }       ]     }-  }+  },+  "title": "VHF201209H3N3ST",+  "brief": "FH Guangdong Fenghua Advanced Tech Inductors (SMD), 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "discovery_triggers": [+    "vhf201209h3n3st"+  ],+  "discovery_pitch": "VHF201209H3N3ST (FH Guangdong Fenghua Advanced Tech) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+  "visibility": "public" }
page.json+6−7
@@ -4,7 +4,7 @@   "slug": "vhf201209h3n3st",   "title": "VHF201209H3N3ST",   "brief": "FH Guangdong Fenghua Advanced Tech Inductors (SMD), 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",-  "version": "0.1.0",+  "version": "0.1.1",   "license": "CC-BY-SA-4.0",   "tags": [     "component",@@ -589,10 +589,9 @@     "viewers/symbol.html",     "viewers/footprint.html",     "vhf201209h3n3st-hero.glb",-    "vhf201209h3n3st-hero.overlay.json",-    "vhf201209h3n3st-etched.glb"+    "vhf201209h3n3st-hero.overlay.json"   ],-  "visibility": {-    "public": true-  }-}+  "visibility": "public",+  "description": "FH Guangdong Fenghua Advanced Tech Inductors (SMD), 0805. Unpolarised two-terminal part: the datasheet prints no pin numbers, so pins 1 and 2 follow the library convention, KiCad symbol/footprint/3D.",+  "org": "adom"+}\ No newline at end of file
vhf201209h3n3st-hero.glb
⋯ 1 unchanged line ⋯
vhf201209h3n3st-hero.overlay.json+3−3
@@ -66,14 +66,14 @@     "seating_z_mm": 0.0   },   "sources": {-    "glb": "vhf201209h3n3st-etched.glb",-    "glb_sha256": "7cfcbcdc7540bc1e0469af8725ada2ffca8dbe0cd7884608844b61d065d568ad",+    "glb": "vhf201209h3n3st.glb",+    "glb_sha256": "6cf7bf6cc9879223bab323612ecd2bada945d43994f6dddc8e6d9af729997f9d",     "footprint": "vhf201209h3n3st.kicad_mod",     "footprint_sha256": "22f5100d304229ddc07ba8218e3b631d6db4f8fe0b5c310b078c7e41ad56517d",     "pins": "page.json component.pins",     "pins_sha256": "f89b6cef1dd40bf094bc57ef23dc246a408922a81bfac75b8bc341584ea4e214"   },-  "generator": "adom-wiki 1.8.11 (component_hero)",+  "generator": "adom-wiki 1.8.30 (component_hero)",   "labels": [     {       "pad": "1",