← Commit history

Set visibility: public

Ray ·9fdb09749f ·1mo ago ·parent 5bc1969
1 file changed +6−3
page.json+6−3
@@ -38,13 +38,13 @@         "number": "2",         "name": "RESET",         "type": "output",-        "description": "Active-low, open-drain reset output. Remains low while VCC is below the reset threshold (typ 2.63 V for the R version) and for at least 140 ms after VCC rises above the threshold. Requires an external pull-up resistor; the pull-up may be tied to a rail higher than VCC. VOL \u2264 0.3 V at ISINK = 50 \u00b5A with VCC \u2265 1.0 V."+        "description": "Active-low, open-drain reset output. Remains low while VCC is below the reset threshold (typ 2.63 V for the R version) and for at least 140 ms after VCC rises above the threshold. Requires an external pull-up resistor; the pull-up may be tied to a rail higher than VCC. VOL ≤ 0.3 V at ISINK = 50 µA with VCC ≥ 1.0 V."       },       {         "number": "3",         "name": "VCC",         "type": "power_in",-        "description": "Positive supply and monitored voltage. Absolute max \u22120.3 V to +6.0 V; operating range 1.0 V to 5.5 V. The R version monitors a nominal +3.0 V rail (reset threshold 2.63 V typ)."+        "description": "Positive supply and monitored voltage. Absolute max −0.3 V to +6.0 V; operating range 1.0 V to 5.5 V. The R version monitors a nominal +3.0 V rail (reset threshold 2.63 V typ)."       }     ],     "provenance": {@@ -108,5 +108,8 @@     "docs/um803rs-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file