← Commit history
page.json+8−5@@ -32,7 +32,7 @@ "number": "1", "name": "RO", "type": "output",- "description": "Receiver Output. If (A-B) \u2265 -50mV, RO is high; if (A-B) \u2264 -200mV, RO is low. High-impedance when RE is high."+ "description": "Receiver Output. If (A-B) ≥ -50mV, RO is high; if (A-B) ≤ -200mV, RO is low. High-impedance when RE is high." }, { "number": "2",@@ -62,19 +62,19 @@ "number": "6", "name": "A", "type": "bidirectional",- "description": "Non-Inverting Receiver Input and Non-Inverting Driver Output (RS-485 bus line A). Rated -7V to +12V common-mode; \u00b115kV HBM ESD protection."+ "description": "Non-Inverting Receiver Input and Non-Inverting Driver Output (RS-485 bus line A). Rated -7V to +12V common-mode; ±15kV HBM ESD protection." }, { "number": "7", "name": "B", "type": "bidirectional",- "description": "Inverting Receiver Input and Inverting Driver Output (RS-485 bus line B). Rated -7V to +12V common-mode; \u00b115kV HBM ESD protection."+ "description": "Inverting Receiver Input and Inverting Driver Output (RS-485 bus line B). Rated -7V to +12V common-mode; ±15kV HBM ESD protection." }, { "number": "8", "name": "VCC", "type": "power_in",- "description": "Power supply for the RS-485 transceiver. Operating range +5V \u00b15%; absolute maximum +7V."+ "description": "Power supply for the RS-485 transceiver. Operating range +5V ±5%; absolute maximum +7V." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/um3352eesa-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }