component
TUSB2036
Public Made by Adomby adom
TI 3-port USB 2.0 full-speed hub, LQFP-32. Bus- or self-powered, ganged or per-port power. Datasheet-verified.
← Commit history
tusb2036: backfill missing artifacts (etch-FAILED:HTTP Error 524: <none>, variants)
2 files changed
+19−3
README.md+2@@ -55,6 +55,8 @@ Turns one upstream USB port into three downstream ports, in a USB 2.0 full-speed ## Ordering variants +Same part, different packaging or reel option.+ - `TUSB2036VF (LQFP-32)` - `TUSB2036IVF (LQFP-32, industrial)` - `TUSB2036IPT (LQFP-32)`
page.json+17−3@@ -54,19 +54,19 @@ "number": "4", "name": "RESET", "type": "input",- "description": "Active-low TTL reset input with hysteresis. Must be asserted at power up; recommended pulse width 100 \u03bcs-1 ms after VCC reaches 90%. Clock must be active during the last 60 \u03bcs of the reset window."+ "description": "Active-low TTL reset input with hysteresis. Must be asserted at power up; recommended pulse width 100 μs-1 ms after VCC reaches 90%. Clock must be active during the last 60 μs of the reset window." }, { "number": "5", "name": "EECLK", "type": "output",- "description": "EEPROM serial clock. When EXTMEM is low, EECLK acts as a 3-state serial clock output to the EEPROM with a 100-\u03bcA internal pulldown. When EXTMEM is high the EEPROM interface is disabled and this pin must be left floating."+ "description": "EEPROM serial clock. When EXTMEM is low, EECLK acts as a 3-state serial clock output to the EEPROM with a 100-μA internal pulldown. When EXTMEM is high the EEPROM interface is disabled and this pin must be left floating." }, { "number": "6", "name": "EEDATA/GANGED", "type": "bidirectional",- "description": "Muxed EEPROM serial data / power-management mode indicator. When EXTMEM is low it is the serial data I/O for the EEPROM (100-\u03bcA internal pulldown). When EXTMEM is high it selects ganged vs. per-port overcurrent detection for the downstream ports; TTL input that must not change dynamically during operation."+ "description": "Muxed EEPROM serial data / power-management mode indicator. When EXTMEM is low it is the serial data I/O for the EEPROM (100-μA internal pulldown). When EXTMEM is high it selects ganged vs. per-port overcurrent detection for the downstream ports; TTL input that must not change dynamically during operation." }, { "number": "7",@@ -292,5 +292,19 @@ "docs/tusb2036-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"+ ],+ "variants": [+ {+ "mpn": "TUSB2036VF (LQFP-32)",+ "kind": "packaging"+ },+ {+ "mpn": "TUSB2036IVF (LQFP-32, industrial)",+ "kind": "packaging"+ },+ {+ "mpn": "TUSB2036IPT (LQFP-32)",+ "kind": "packaging"+ } ] }