← Commit history

tusb2036: backfill missing artifacts (etch-FAILED:HTTP Error 524: <none>, variants)

Ray ·6616ff7559 ·2mo ago ·parent c554f93
2 files changed +19−3
README.md+2
@@ -55,6 +55,8 @@ Turns one upstream USB port into three downstream ports, in a USB 2.0 full-speed  ## Ordering variants +Same part, different packaging or reel option.+ - `TUSB2036VF (LQFP-32)` - `TUSB2036IVF (LQFP-32, industrial)` - `TUSB2036IPT (LQFP-32)`
page.json+17−3
@@ -54,19 +54,19 @@         "number": "4",         "name": "RESET",         "type": "input",-        "description": "Active-low TTL reset input with hysteresis. Must be asserted at power up; recommended pulse width 100 \u03bcs-1 ms after VCC reaches 90%. Clock must be active during the last 60 \u03bcs of the reset window."+        "description": "Active-low TTL reset input with hysteresis. Must be asserted at power up; recommended pulse width 100 μs-1 ms after VCC reaches 90%. Clock must be active during the last 60 μs of the reset window."       },       {         "number": "5",         "name": "EECLK",         "type": "output",-        "description": "EEPROM serial clock. When EXTMEM is low, EECLK acts as a 3-state serial clock output to the EEPROM with a 100-\u03bcA internal pulldown. When EXTMEM is high the EEPROM interface is disabled and this pin must be left floating."+        "description": "EEPROM serial clock. When EXTMEM is low, EECLK acts as a 3-state serial clock output to the EEPROM with a 100-μA internal pulldown. When EXTMEM is high the EEPROM interface is disabled and this pin must be left floating."       },       {         "number": "6",         "name": "EEDATA/GANGED",         "type": "bidirectional",-        "description": "Muxed EEPROM serial data / power-management mode indicator. When EXTMEM is low it is the serial data I/O for the EEPROM (100-\u03bcA internal pulldown). When EXTMEM is high it selects ganged vs. per-port overcurrent detection for the downstream ports; TTL input that must not change dynamically during operation."+        "description": "Muxed EEPROM serial data / power-management mode indicator. When EXTMEM is low it is the serial data I/O for the EEPROM (100-μA internal pulldown). When EXTMEM is high it selects ganged vs. per-port overcurrent detection for the downstream ports; TTL input that must not change dynamically during operation."       },       {         "number": "7",@@ -292,5 +292,19 @@     "docs/tusb2036-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"+  ],+  "variants": [+    {+      "mpn": "TUSB2036VF (LQFP-32)",+      "kind": "packaging"+    },+    {+      "mpn": "TUSB2036IVF (LQFP-32, industrial)",+      "kind": "packaging"+    },+    {+      "mpn": "TUSB2036IPT (LQFP-32)",+      "kind": "packaging"+    }   ] }\ No newline at end of file