component
TSV791ILT
Public Made by Adomby adom
STMicroelectronics Operational Amplifier, SOT-23-5. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
tsv791ilt: specified limits as data (metadata.characteristics, 60 rows from the datasheet)
2 files changed
+795−1
README.md+67@@ -23,6 +23,73 @@ TSV791ILT from STMicroelectronics, in a SOT-23-5. Pinout and pin descriptions ex | Category | Amplifiers/Comparators | | Pins | 5 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input offset voltage | Vio | -200 | | 200 | µV | VCC = 5 V, T = 25 °C | 6 |+| Input offset voltage | Vio | -700 | | 700 | µV | VCC = 5 V, -40 °C ≤ T ≤ 125 °C | 6 |+| Input offset voltage temperature drift | ∆Vio/∆T | -5 | | 5 | µV/°C | VCC = 5 V, -40 °C ≤ T ≤ 125 °C | 6 |+| Input bias current | Iib | | 2 | 5 | pA | VCC = 5 V, T = 25 °C | 6 |+| Input bias current | Iib | | 75 | 300 | pA | VCC = 5 V, -40 °C ≤ T ≤ 125 °C | 6 |+| Input offset current | Iio | | 1 | 5 | pA | VCC = 5 V, T = 25 °C | 6 |+| Input offset current | Iio | | 20 | 300 | pA | VCC = 5 V, -40 °C ≤ T ≤ 125 °C | 6 |+| Open loop gain | AVD | 110 | 133 | | dB | VCC = 5 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C | 6 |+| Open loop gain | AVD | 90 | 113 | | dB | VCC = 5 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C | 6 |+| Open loop gain (RL = 600 Ω) | AVD | 105 | 132 | | dB | VCC = 5 V, RL = 600 Ω, T = 25 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV | 6 |+| Common-mode rejection ratio | CMR1 | 100 | 120 | | dB | VCC = 5 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, T = 25 °C | 6 |+| Common-mode rejection ratio | CMR1 | 90 | 120 | | dB | VCC = 5 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, -40 °C ≤ T ≤ 125 °C | 6 |+| Common-mode rejection ratio | CMR2 | 80 | 100 | | dB | VCC = 5 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C | 6 |+| Common-mode rejection ratio | CMR2 | 76 | 92 | | dB | VCC = 5 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C | 6 |+| Supply-voltage rejection ratio | SVR | 90 | 109 | | dB | 2.2 V ≤ VCC ≤ 5.5 V, T = 25 °C, Vicm = 0 V | 6 |+| Supply-voltage rejection ratio | SVR | 90 | 108 | | dB | 2.2 V ≤ VCC ≤ 5.5 V, -40 °C ≤ T ≤ 125 °C, Vicm = 0 V | 6 |+| Output source/sink current (sink) | ISINK | 60 | 70 | | mA | VCC = 5 V, OUT connected to VCC+, T = 25 °C | 6 |+| Output source current | ISOURCE | 50 | 60 | | mA | VCC = 5 V, OUT connected to VCC-, T = 25 °C | 6 |+| Supply current (by operational amplifier) | ICC | | 5.5 | 6 | mA | VCC = 5 V, T = 25 °C | 7 |+| Gain bandwidth product | GBP | 35 | 50 | | MHz | VCC = 5 V, RL = 10 kΩ, CL = 22 pF | 7 |+| Input offset voltage | Vio | -200 | | 200 | µV | VCC = 3.3 V, Vicm = 0 V, T = 25 °C | 8 |+| Input offset voltage | Vio | -700 | | 700 | µV | VCC = 3.3 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C | 8 |+| Input offset voltage temperature drift | ∆Vio/∆T | -5 | | 5 | µV/°C | VCC = 3.3 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C | 8 |+| Input bias current | Iib | | 1.5 | 5 | pA | VCC = 3.3 V, T = 25 °C | 8 |+| Input bias current | Iib | | 60 | 300 | pA | VCC = 3.3 V, -40 °C ≤ T ≤ 125 °C | 8 |+| Input offset current | Iio | | 1 | 5 | pA | VCC = 3.3 V, T = 25 °C | 8 |+| Input offset current | Iio | | 20 | 300 | pA | VCC = 3.3 V, -40 °C ≤ T ≤ 125 °C | 8 |+| Open loop gain | AVD | 105 | 130 | | dB | VCC = 3.3 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C | 8 |+| Open loop gain | AVD | 90 | 113 | | dB | VCC = 3.3 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C | 8 |+| Open loop gain (RL = 600 Ω) | AVD | 100 | 129 | | dB | VCC = 3.3 V, RL = 600 Ω, T = 25 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV | 8 |+| Open loop gain (RL = 600 Ω) | AVD | 85 | 99 | | dB | VCC = 3.3 V, RL = 600 Ω, -40 °C ≤ T ≤ 125 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV | 8 |+| Common-mode rejection ratio | CMR1 | 95 | 116 | | dB | VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, T = 25 °C | 8 |+| Common-mode rejection ratio | CMR1 | 85 | 111 | | dB | VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, -40 °C ≤ T ≤ 125 °C | 8 |+| Common-mode rejection ratio | CMR2 | 77 | 97 | | dB | VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C | 8 |+| Common-mode rejection ratio | CMR2 | 70 | 90 | | dB | VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C | 8 |+| Output source/sink current (sink) | ISINK | 55 | 63 | | mA | VCC = 3.3 V, OUT connected to VCC+, T = 25 °C | 8 |+| Output source current | ISOURCE | 50 | 63 | | mA | VCC = 3.3 V, OUT connected to VCC-, T = 25 °C | 8 |+| Supply current (by operational amplifier) | ICC | | 5.3 | 5.8 | mA | VCC = 3.3 V, T = 25 °C | 8 |+| Gain bandwidth product | GBP | 35 | 50 | | MHz | VCC = 3.3 V, RL = 10 kΩ, CL = 22 pF | 8 |+| Input offset voltage | Vio | -200 | 50 | 200 | µV | VCC = 2.2 V, Vicm = 0 V, T = 25 °C | 10 |+| Input offset voltage | Vio | -700 | | 700 | µV | VCC = 2.2 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C | 10 |+| Input offset voltage temperature drift | ∆Vio/∆T | -5 | | 5 | µV/°C | VCC = 2.2 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C | 10 |+| Input bias current | Iib | | 1 | 5 | pA | VCC = 2.2 V, T = 25 °C | 10 |+| Input bias current | Iib | | 45 | 300 | pA | VCC = 2.2 V, -40 °C ≤ T ≤ 125 °C | 10 |+| Input offset current | Iio | | 1 | 5 | pA | VCC = 2.2 V, T = 25 °C | 10 |+| Input offset current | Iio | | 13 | 300 | pA | VCC = 2.2 V, -40 °C ≤ T ≤ 125 °C | 10 |+| Open loop gain | AVD | 95 | 120 | | dB | VCC = 2.2 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C | 10 |+| Open loop gain | AVD | 85 | 107 | | dB | VCC = 2.2 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C | 10 |+| Open loop gain (RL = 600 Ω) | AVD | 90 | 119 | | dB | VCC = 2.2 V, RL = 600 Ω, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV, T = 25 °C | 10 |+| Open loop gain (RL = 600 Ω) | AVD | 80 | 99 | | dB | VCC = 2.2 V, RL = 600 Ω, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV, -40 °C ≤ T ≤ 125 °C | 10 |+| Common-mode rejection ratio | CMR | 73 | 94 | | dB | VCC = 2.2 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C | 10 |+| Common-mode rejection ratio | CMR | 67 | 85 | | dB | VCC = 2.2 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C | 10 |+| Supply current (by operational amplifier) | ICC | | 5 | 5.5 | mA | VCC = 2.2 V, Vicm = 0 V, T = 25 °C | 10 |+| Gain bandwidth product | GBP | 35 | 50 | | MHz | VCC = 2.2 V, RL = 10 kΩ | 10 |+| Supply voltage | VCC | | | 6 | V | | 5 |+| Input current | Iin | -10 | | 10 | mA | | 5 |+| Storage temperature | Tstg | -65 | | 150 | °C | | 5 |+| Supply voltage | VCC | 2.2 | | 5.5 | V | | 5 |+| Operating free air temperature range | Toper | -40 | | 125 | °C | | 5 |+| Thermal resistance junction-to-ambient (SOT23-5) | Rth-ja | | 250 | | °C / W | SOT23-5, typical value, PCB per JEDEC 2s2p without vias | 5 |+ ## CAD (KiCad official) - Symbol: `TSV791ILT`
page.json+728−1@@ -162,6 +162,733 @@ "Package": "SOT-23-5", "Category": "Amplifiers/Comparators", "Pins": "5"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "c3b83741b07a0372",+ "rows": [+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -200,+ "typ": null,+ "max": 200,+ "conditions": "VCC = 5 V, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -700,+ "typ": null,+ "max": 700,+ "conditions": "VCC = 5 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage temperature drift",+ "symbol": "∆Vio/∆T",+ "kind": "temperature_coefficient",+ "unit": "µV/°C",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "VCC = 5 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 2,+ "max": 5,+ "conditions": "VCC = 5 V, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 75,+ "max": 300,+ "conditions": "VCC = 5 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 5,+ "conditions": "VCC = 5 V, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 20,+ "max": 300,+ "conditions": "VCC = 5 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 110,+ "typ": 133,+ "max": null,+ "conditions": "VCC = 5 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 113,+ "max": null,+ "conditions": "VCC = 5 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain (RL = 600 Ω)",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 105,+ "typ": 132,+ "max": null,+ "conditions": "VCC = 5 V, RL = 600 Ω, T = 25 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR1",+ "kind": "electrical",+ "unit": "dB",+ "min": 100,+ "typ": 120,+ "max": null,+ "conditions": "VCC = 5 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR1",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 120,+ "max": null,+ "conditions": "VCC = 5 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR2",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": 100,+ "max": null,+ "conditions": "VCC = 5 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR2",+ "kind": "electrical",+ "unit": "dB",+ "min": 76,+ "typ": 92,+ "max": null,+ "conditions": "VCC = 5 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio",+ "symbol": "SVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 109,+ "max": null,+ "conditions": "2.2 V ≤ VCC ≤ 5.5 V, T = 25 °C, Vicm = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Supply-voltage rejection ratio",+ "symbol": "SVR",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 108,+ "max": null,+ "conditions": "2.2 V ≤ VCC ≤ 5.5 V, -40 °C ≤ T ≤ 125 °C, Vicm = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output source/sink current (sink)",+ "symbol": "ISINK",+ "kind": "electrical",+ "unit": "mA",+ "min": 60,+ "typ": 70,+ "max": null,+ "conditions": "VCC = 5 V, OUT connected to VCC+, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output source current",+ "symbol": "ISOURCE",+ "kind": "electrical",+ "unit": "mA",+ "min": 50,+ "typ": 60,+ "max": null,+ "conditions": "VCC = 5 V, OUT connected to VCC-, T = 25 °C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Supply current (by operational amplifier)",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 5.5,+ "max": 6,+ "conditions": "VCC = 5 V, T = 25 °C",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Gain bandwidth product",+ "symbol": "GBP",+ "kind": "electrical",+ "unit": "MHz",+ "min": 35,+ "typ": 50,+ "max": null,+ "conditions": "VCC = 5 V, RL = 10 kΩ, CL = 22 pF",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -200,+ "typ": null,+ "max": 200,+ "conditions": "VCC = 3.3 V, Vicm = 0 V, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -700,+ "typ": null,+ "max": 700,+ "conditions": "VCC = 3.3 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage temperature drift",+ "symbol": "∆Vio/∆T",+ "kind": "temperature_coefficient",+ "unit": "µV/°C",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "VCC = 3.3 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1.5,+ "max": 5,+ "conditions": "VCC = 3.3 V, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 60,+ "max": 300,+ "conditions": "VCC = 3.3 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 5,+ "conditions": "VCC = 3.3 V, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 20,+ "max": 300,+ "conditions": "VCC = 3.3 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 105,+ "typ": 130,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 113,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain (RL = 600 Ω)",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 100,+ "typ": 129,+ "max": null,+ "conditions": "VCC = 3.3 V, RL = 600 Ω, T = 25 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain (RL = 600 Ω)",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": 99,+ "max": null,+ "conditions": "VCC = 3.3 V, RL = 600 Ω, -40 °C ≤ T ≤ 125 °C, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR1",+ "kind": "electrical",+ "unit": "dB",+ "min": 95,+ "typ": 116,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR1",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": 111,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+ - 2 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR2",+ "kind": "electrical",+ "unit": "dB",+ "min": 77,+ "typ": 97,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR2",+ "kind": "electrical",+ "unit": "dB",+ "min": 70,+ "typ": 90,+ "max": null,+ "conditions": "VCC = 3.3 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Output source/sink current (sink)",+ "symbol": "ISINK",+ "kind": "electrical",+ "unit": "mA",+ "min": 55,+ "typ": 63,+ "max": null,+ "conditions": "VCC = 3.3 V, OUT connected to VCC+, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Output source current",+ "symbol": "ISOURCE",+ "kind": "electrical",+ "unit": "mA",+ "min": 50,+ "typ": 63,+ "max": null,+ "conditions": "VCC = 3.3 V, OUT connected to VCC-, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Supply current (by operational amplifier)",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 5.3,+ "max": 5.8,+ "conditions": "VCC = 3.3 V, T = 25 °C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Gain bandwidth product",+ "symbol": "GBP",+ "kind": "electrical",+ "unit": "MHz",+ "min": 35,+ "typ": 50,+ "max": null,+ "conditions": "VCC = 3.3 V, RL = 10 kΩ, CL = 22 pF",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -200,+ "typ": 50,+ "max": 200,+ "conditions": "VCC = 2.2 V, Vicm = 0 V, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage",+ "symbol": "Vio",+ "kind": "electrical",+ "unit": "µV",+ "min": -700,+ "typ": null,+ "max": 700,+ "conditions": "VCC = 2.2 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input offset voltage temperature drift",+ "symbol": "∆Vio/∆T",+ "kind": "temperature_coefficient",+ "unit": "µV/°C",+ "min": -5,+ "typ": null,+ "max": 5,+ "conditions": "VCC = 2.2 V, Vicm = 0 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 5,+ "conditions": "VCC = 2.2 V, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input bias current",+ "symbol": "Iib",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 45,+ "max": 300,+ "conditions": "VCC = 2.2 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 1,+ "max": 5,+ "conditions": "VCC = 2.2 V, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Input offset current",+ "symbol": "Iio",+ "kind": "electrical",+ "unit": "pA",+ "min": null,+ "typ": 13,+ "max": 300,+ "conditions": "VCC = 2.2 V, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 95,+ "typ": 120,+ "max": null,+ "conditions": "VCC = 2.2 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 85,+ "typ": 107,+ "max": null,+ "conditions": "VCC = 2.2 V, VCC- + 200 mV ≤ VOUT ≤ VCC+ - 200 mV, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain (RL = 600 Ω)",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 90,+ "typ": 119,+ "max": null,+ "conditions": "VCC = 2.2 V, RL = 600 Ω, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Open loop gain (RL = 600 Ω)",+ "symbol": "AVD",+ "kind": "electrical",+ "unit": "dB",+ "min": 80,+ "typ": 99,+ "max": null,+ "conditions": "VCC = 2.2 V, RL = 600 Ω, VCC- + 300 mV ≤ VOUT ≤ VCC+ - 300 mV, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR",+ "kind": "electrical",+ "unit": "dB",+ "min": 73,+ "typ": 94,+ "max": null,+ "conditions": "VCC = 2.2 V, VCC- ≤ Vicm ≤ VCC+, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Common-mode rejection ratio",+ "symbol": "CMR",+ "kind": "electrical",+ "unit": "dB",+ "min": 67,+ "typ": 85,+ "max": null,+ "conditions": "VCC = 2.2 V, VCC- ≤ Vicm ≤ VCC+, -40 °C ≤ T ≤ 125 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Supply current (by operational amplifier)",+ "symbol": "ICC",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 5,+ "max": 5.5,+ "conditions": "VCC = 2.2 V, Vicm = 0 V, T = 25 °C",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Gain bandwidth product",+ "symbol": "GBP",+ "kind": "electrical",+ "unit": "MHz",+ "min": 35,+ "typ": 50,+ "max": null,+ "conditions": "VCC = 2.2 V, RL = 10 kΩ",+ "source_page": 10,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage",+ "symbol": "VCC",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input current",+ "symbol": "Iin",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": -10,+ "typ": null,+ "max": 10,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -65,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Supply voltage",+ "symbol": "VCC",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2.2,+ "typ": null,+ "max": 5.5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating free air temperature range",+ "symbol": "Toper",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Thermal resistance junction-to-ambient (SOT23-5)",+ "symbol": "Rth-ja",+ "kind": "thermal",+ "unit": "°C / W",+ "min": null,+ "typ": 250,+ "max": null,+ "conditions": "SOT23-5, typical value, PCB per JEDEC 2s2p without vias",+ "source_page": 5,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -203,4 +930,4 @@ "visibility": { "public": true }-}+}