← Commit history
ts5a23157dgsr-tp: restore the component block (pinout + model declarations) from this page's own README and symbol
1 file changed
+86−1
page.json+86−1@@ -33,5 +33,90 @@ "author": { "name": "Ray", "email": "[email protected]"+ },+ "component": {+ "mpn": "TS5A23157DGSR-TP",+ "manufacturer": "TECH PUBLIC",+ "package": "MSOP-10L",+ "pin_count": 10,+ "category": "Analog Switches, Multiplexers",+ "parts": {+ "symbol": "ts5a23157dgsr-tp.kicad_sym",+ "footprint": "ts5a23157dgsr-tp.kicad_mod",+ "model_3d": "ts5a23157dgsr-tp-etched.glb",+ "model_3d_plain": "ts5a23157dgsr-tp.glb",+ "model_3d_step": "ts5a23157dgsr-tp-etched.step",+ "model_3d_step_plain": "ts5a23157dgsr-tp.step",+ "lbr": "ts5a23157dgsr-tp.lbr"+ },+ "pins": [+ {+ "number": "1",+ "name": "IN1",+ "type": "input",+ "description": "Digital control input for switch 1. Selects whether COM1 connects to NO1 (IN1=1) or NC1 (IN1=0). 1.8 V logic compatible; VIH ≥ 1.6 V (VCC=3.3-5.5 V) or ≥ 1.4 V (VCC=1.5-3.3 V), VIL ≤ 0.6 V / 0.4 V respectively."+ },+ {+ "number": "2",+ "name": "NO1",+ "type": "passive",+ "description": "Analog/digital signal port for switch 1, normally open. Connects to COM1 when IN1 = 1. Signal voltage range -0.3 V to 5.5 V; continuous current ±100 mA (±200 mA pulsed)."+ },+ {+ "number": "3",+ "name": "GND",+ "type": "power_in",+ "description": "Ground reference (0 V) for the device."+ },+ {+ "number": "4",+ "name": "NO2",+ "type": "passive",+ "description": "Analog/digital signal port for switch 2, normally open. Connects to COM2 when IN2 = 1. Signal voltage range -0.3 V to 5.5 V; continuous current ±100 mA (±200 mA pulsed)."+ },+ {+ "number": "5",+ "name": "IN2",+ "type": "input",+ "description": "Digital control input for switch 2. Selects whether COM2 connects to NO2 (IN2=1) or NC2 (IN2=0). 1.8 V logic compatible; VIH ≥ 1.6 V (VCC=3.3-5.5 V) or ≥ 1.4 V (VCC=1.5-3.3 V), VIL ≤ 0.6 V / 0.4 V respectively."+ },+ {+ "number": "6",+ "name": "COM2",+ "type": "passive",+ "description": "Port 2 common data terminal. Connects to NC2 or NO2 according to the IN2 select logic. Ron ≈ 3.5 Ω typ; supports true isolation - COMx overrides VCC so very little current flows back to the supply when VCC is dead."+ },+ {+ "number": "7",+ "name": "NC2",+ "type": "passive",+ "description": "Analog/digital signal port for switch 2, normally closed. Connects to COM2 when IN2 = 0. Signal voltage range -0.3 V to 5.5 V; continuous current ±100 mA (±200 mA pulsed)."+ },+ {+ "number": "8",+ "name": "V+",+ "type": "power_in",+ "description": "Positive supply voltage (VCC). Operating range 1.5 V to 5.5 V; absolute maximum 6.5 V. Quiescent current < 2 µA (typ 1 µA)."+ },+ {+ "number": "9",+ "name": "NC1",+ "type": "passive",+ "description": "Analog/digital signal port for switch 1, normally closed. Connects to COM1 when IN1 = 0. Signal voltage range -0.3 V to 5.5 V; continuous current ±100 mA (±200 mA pulsed)."+ },+ {+ "number": "10",+ "name": "COM1",+ "type": "passive",+ "description": "Port 1 common data terminal. Connects to NC1 or NO1 according to the IN1 select logic. Ron ≈ 3.5 Ω typ; supports true isolation - COMx overrides VCC so very little current flows back to the supply when VCC is dead."+ }+ ],+ "provenance": {+ "rebuilt": "component block rebuilt 2026-10-05 from this page's own README pinout table and .kicad_sym (pins cross-checked), no re-extraction"+ },+ "viewers": {+ "symbol": "viewers/symbol.html",+ "footprint": "viewers/footprint.html"+ } }-}+}