← Commit history
page.json+9−6@@ -32,7 +32,7 @@ "number": "1", "name": "TXD", "type": "input",- "description": "CAN transmit data input from the CAN controller. LOW drives a dominant bus state; HIGH allows a recessive bus state. Logic thresholds referenced to VIO (VIH \u2265 0.7\u00d7VIO, VIL \u2264 0.3\u00d7VIO). Input capacitance ~5 pF."+ "description": "CAN transmit data input from the CAN controller. LOW drives a dominant bus state; HIGH allows a recessive bus state. Logic thresholds referenced to VIO (VIH ≥ 0.7×VIO, VIL ≤ 0.3×VIO). Input capacitance ~5 pF." }, { "number": "2",@@ -50,7 +50,7 @@ "number": "4", "name": "RXD", "type": "output",- "description": "CAN receive data output to the CAN controller. LOW indicates a dominant bus state; HIGH indicates a recessive bus state. Output swing referenced to VIO; drive capability \u00b12 mA (max \u00b18 mA)."+ "description": "CAN receive data output to the CAN controller. LOW indicates a dominant bus state; HIGH indicates a recessive bus state. Output swing referenced to VIO; drive capability ±2 mA (max ±8 mA)." }, { "number": "5",@@ -62,19 +62,19 @@ "number": "6", "name": "CANL", "type": "bidirectional",- "description": "Low-level CAN bus input/output line. Differential pair with CANH; driven low relative to CANH in the dominant state. \u00b170 V bus fault protection and \u00b115 kV IEC 61000-4-2 ESD protection. Common-mode range \u00b130 V."+ "description": "Low-level CAN bus input/output line. Differential pair with CANH; driven low relative to CANH in the dominant state. ±70 V bus fault protection and ±15 kV IEC 61000-4-2 ESD protection. Common-mode range ±30 V." }, { "number": "7", "name": "CANH", "type": "bidirectional",- "description": "High-level CAN bus input/output line. Differential pair with CANL; driven high relative to CANL in the dominant state. \u00b170 V bus fault protection and \u00b115 kV IEC 61000-4-2 ESD protection. Common-mode range \u00b130 V."+ "description": "High-level CAN bus input/output line. Differential pair with CANL; driven high relative to CANL in the dominant state. ±70 V bus fault protection and ±15 kV IEC 61000-4-2 ESD protection. Common-mode range ±30 V." }, { "number": "8", "name": "STB", "type": "input",- "description": "Standby Mode control input (active high). HIGH places the device in low-current standby mode with CAN bus wake-up capability; LOW selects normal operating mode. Logic thresholds referenced to VIO (VIH \u2265 0.7\u00d7VIO, VIL \u2264 0.3\u00d7VIO)."+ "description": "Standby Mode control input (active high). HIGH places the device in low-current standby mode with CAN bus wake-up capability; LOW selects normal operating mode. Logic thresholds referenced to VIO (VIH ≥ 0.7×VIO, VIL ≤ 0.3×VIO)." } ], "provenance": {@@ -138,5 +138,8 @@ "docs/tpt1042v-so1r-s-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }