← Commit history
page.json+13−10@@ -32,13 +32,13 @@ "number": "1", "name": "IN1", "type": "input",- "description": "Digital control input for switch 1: selects whether COM1 connects to NO1 (IN1=1) or NC1 (IN1=0). 1.8 V logic compatible; VIH \u2265 1.4 V (VCC=1.5-3.3V) or \u2265 1.6 V (VCC=3.3-5.5V), VIL \u2264 0.4 V or \u2264 0.6 V respectively."+ "description": "Digital control input for switch 1: selects whether COM1 connects to NO1 (IN1=1) or NC1 (IN1=0). 1.8 V logic compatible; VIH ≥ 1.4 V (VCC=1.5-3.3V) or ≥ 1.6 V (VCC=3.3-5.5V), VIL ≤ 0.4 V or ≤ 0.6 V respectively." }, { "number": "2", "name": "NO1", "type": "passive",- "description": "Analog/digital signal port for switch 1, normally open. Connected to COM1 when IN1=1. Signal range -0.3 V to 5.5 V; continuous current \u00b1100 mA, peak \u00b1200 mA."+ "description": "Analog/digital signal port for switch 1, normally open. Connected to COM1 when IN1=1. Signal range -0.3 V to 5.5 V; continuous current ±100 mA, peak ±200 mA." }, { "number": "3",@@ -50,43 +50,43 @@ "number": "4", "name": "NO2", "type": "passive",- "description": "Analog/digital signal port for switch 2, normally open. Connected to COM2 when IN2=1. Signal range -0.3 V to 5.5 V; continuous current \u00b1100 mA, peak \u00b1200 mA."+ "description": "Analog/digital signal port for switch 2, normally open. Connected to COM2 when IN2=1. Signal range -0.3 V to 5.5 V; continuous current ±100 mA, peak ±200 mA." }, { "number": "5", "name": "IN2", "type": "input",- "description": "Digital control input for switch 2: selects whether COM2 connects to NO2 (IN2=1) or NC2 (IN2=0). 1.8 V logic compatible; VIH \u2265 1.4 V (VCC=1.5-3.3V) or \u2265 1.6 V (VCC=3.3-5.5V), VIL \u2264 0.4 V or \u2264 0.6 V respectively."+ "description": "Digital control input for switch 2: selects whether COM2 connects to NO2 (IN2=1) or NC2 (IN2=0). 1.8 V logic compatible; VIH ≥ 1.4 V (VCC=1.5-3.3V) or ≥ 1.6 V (VCC=3.3-5.5V), VIL ≤ 0.4 V or ≤ 0.6 V respectively." }, { "number": "6", "name": "COM2", "type": "passive",- "description": "Port 2 common data terminal. Connects to NC2 or NO2 according to the IN2 select logic. Ron typ 1.5 \u03a9 at COM=5V; break-before-make with 500 ns tBBM."+ "description": "Port 2 common data terminal. Connects to NC2 or NO2 according to the IN2 select logic. Ron typ 1.5 Ω at COM=5V; break-before-make with 500 ns tBBM." }, { "number": "7", "name": "NC2", "type": "passive",- "description": "Analog/digital signal port for switch 2, normally closed. Connected to COM2 when IN2=0. Signal range -0.3 V to 5.5 V; continuous current \u00b1100 mA, peak \u00b1200 mA."+ "description": "Analog/digital signal port for switch 2, normally closed. Connected to COM2 when IN2=0. Signal range -0.3 V to 5.5 V; continuous current ±100 mA, peak ±200 mA." }, { "number": "8", "name": "V+", "type": "power_in",- "description": "Supply voltage VCC. Operating range 1.5 V to 5.5 V; absolute max -0.3 to +6.5 V. Quiescent current < 2 \u00b5A typical."+ "description": "Supply voltage VCC. Operating range 1.5 V to 5.5 V; absolute max -0.3 to +6.5 V. Quiescent current < 2 µA typical." }, { "number": "9", "name": "NC1", "type": "passive",- "description": "Analog/digital signal port for switch 1, normally closed. Connected to COM1 when IN1=0. Signal range -0.3 V to 5.5 V; continuous current \u00b1100 mA, peak \u00b1200 mA."+ "description": "Analog/digital signal port for switch 1, normally closed. Connected to COM1 when IN1=0. Signal range -0.3 V to 5.5 V; continuous current ±100 mA, peak ±200 mA." }, { "number": "10", "name": "COM1", "type": "passive",- "description": "Port 1 common data terminal. Connects to NC1 or NO1 according to the IN1 select logic. Ron typ 1.5 \u03a9 at COM=5V; break-before-make with 500 ns tBBM."+ "description": "Port 1 common data terminal. Connects to NC1 or NO1 according to the IN1 select logic. Ron typ 1.5 Ω at COM=5V; break-before-make with 500 ns tBBM." } ], "provenance": {@@ -150,5 +150,8 @@ "docs/tpsgm3002xms-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }