← Commit history
page.json+7−4@@ -38,19 +38,19 @@ "number": "2", "name": "GND", "type": "power_in",- "description": "Device ground reference. GND pin current is nominally 400 \u00b5A at I_OUT = 10 mA and 550 \u00b5A at 150 mA."+ "description": "Device ground reference. GND pin current is nominally 400 µA at I_OUT = 10 mA and 550 µA at 150 mA." }, { "number": "3", "name": "EN", "type": "input",- "description": "Enable input. Drive high (>=1.7 V, up to V_IN) to enable the regulator; drive low (<=0.5 V) to place the device in shutdown (I_SHDN <= 1 \u00b5A). May be tied to IN if unused. Absolute max 6 V."+ "description": "Enable input. Drive high (>=1.7 V, up to V_IN) to enable the regulator; drive low (<=0.5 V) to place the device in shutdown (I_SHDN <= 1 µA). May be tied to IN if unused. Absolute max 6 V." }, { "number": "4", "name": "FB", "type": "input",- "description": "Feedback input to the internal error amplifier (adjustable version, TPS73101 only). Connect an external resistor divider from OUT to FB to GND to program V_OUT from 1.2 V to 5.5 V. Internal reference V_FB = 1.20 V typical; FB input bias current 0.1 \u00b5A typical."+ "description": "Feedback input to the internal error amplifier (adjustable version, TPS73101 only). Connect an external resistor divider from OUT to FB to GND to program V_OUT from 1.2 V to 5.5 V. Internal reference V_FB = 1.20 V typical; FB input bias current 0.1 µA typical." }, { "number": "5",@@ -130,5 +130,8 @@ "docs/tps73101dbvr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }