component
TPS72727DSER
Public Made by Adomby adom
Texas Instruments Voltage Regulators - Linear, Low Drop Out (LDO) Regulators, WSON-6(1.5x1.5). Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
tps72727dser: specified limits as data (metadata.characteristics, 28 rows from the datasheet)
2 files changed
+379−1
README.md+35@@ -24,6 +24,41 @@ TPS72727DSER from Texas Instruments, in a WSON-6(1.5x1.5). Pinout and pin descri | Category | Power Management (PMIC) | | Pins | 6 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage | VIN | -0.3 | | 6 | V | | 5 |+| Enable voltage range | VEN | -0.3 | | 6 | V | | 5 |+| Output voltage range | VOUT | -0.3 | | 6 | V | | 5 |+| Operating junction temperature | TJ | -55 | | 150 | °C | | 5 |+| Storage temperature | Tstg | -55 | | 150 | °C | | 5 |+| Input voltage | VIN | 2 | | 5.5 | V | | 5 |+| Output current | IOUT | 0 | | 250 | mA | | 5 |+| Operating junction temperature range | TJ | -40 | | 125 | °C | | 5 |+| Junction-to-ambient thermal resistance (DSE WSON) | RθJA | | 190.5 | | °C/W | | 5 |+| Junction-to-case (top) thermal resistance (DSE WSON) | RθJC(top) | | 94.9 | | °C/W | | 5 |+| Junction-to-board thermal resistance (DSE WSON) | RθJB | | 149.3 | | °C/W | | 5 |+| Junction-to-top characterization parameter (DSE WSON) | ψJT | | 6.4 | | °C/W | | 5 |+| Junction-to-board characterization parameter (DSE WSON) | ψJB | | 152.8 | | °C/W | | 5 |+| Input voltage range | VIN | 2 | | 5.5 | V | | 6 |+| Output voltage range | VO | 0.9 | | 5 | V | | 6 |+| DC output accuracy | | -2.5 | | 2.5 | mV | TJ = +25°C | 6 |+| DC output accuracy | | -2 | 1 | 2 | % | VOUT + 0.3 V ≤ VIN ≤ 5.5 V, 0 mA ≤ IOUT ≤ 200 mA | 6 |+| DC output accuracy | | -1 | | 1 | % | VOUT + 0.3 V ≤ VIN ≤ 5.5 V, 0 mA ≤ IOUT ≤ 250 mA | 6 |+| Load transient | ΔVOUT | -50 | | 50 | mV | 1 mA to 200 mA or 200 mA to 1 mA in 1 µs, COUT = 1 µF | 6 |+| Load transient | ΔVOUT | -65 | | 65 | mV | 1 mA to 250 mA or 250 mA to 1 mA in 1 µs, COUT = 1 µF | 6 |+| Dropout voltage | VDO | | 130 | 200 | mV | VIN = 0.98 × VOUT(NOM), IOUT = 200 mA | 6 |+| Output current limit | ICL | 300 | 400 | 550 | mA | VOUT = 0.9 × VOUT(NOM) | 6 |+| Ground pin current | IGND | | 7.9 | 12 | µA | IOUT = 0 mA, TJ = –40°C to +125°C | 6 |+| Shutdown current (IGND) | ISHDN | | 0.55 | 2 | µA | EN ≤ 0.4 V, 2.0 V < VIN ≤ 4.5 V, TJ = –40°C to +85°C | 6 |+| Enable pin low (disabled) | VLO | 0 | | 0.4 | V | | 6 |+| Enable pin current | IEN | | 40 | 500 | nA | EN = 5.5 V | 6 |+| Undervoltage lock-out | UVLO | 1.85 | 1.9 | 1.95 | V | VIN rising | 6 |+| Operating junction temperature | TJ | -40 | | 125 | °C | | 6 |+ ## CAD (KiCad official) - Symbol: `TPS72727DSER`
page.json+344−1@@ -168,6 +168,349 @@ "Package": "WSON-6(1.5x1.5)", "Category": "Power Management (PMIC)", "Pins": "6"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "eb07c4ca05ae7371",+ "rows": [+ {+ "name": "Input voltage",+ "symbol": "VIN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Enable voltage range",+ "symbol": "VEN",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range",+ "symbol": "VOUT",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input voltage",+ "symbol": "VIN",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 2,+ "typ": null,+ "max": 5.5,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Output current",+ "symbol": "IOUT",+ "kind": "recommended_operating",+ "unit": "mA",+ "min": 0,+ "typ": null,+ "max": 250,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature range",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance (DSE WSON)",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 190.5,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (top) thermal resistance (DSE WSON)",+ "symbol": "RθJC(top)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 94.9,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-board thermal resistance (DSE WSON)",+ "symbol": "RθJB",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 149.3,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-top characterization parameter (DSE WSON)",+ "symbol": "ψJT",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 6.4,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-board characterization parameter (DSE WSON)",+ "symbol": "ψJB",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 152.8,+ "max": null,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range",+ "symbol": "VIN",+ "kind": "electrical",+ "unit": "V",+ "min": 2,+ "typ": null,+ "max": 5.5,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output voltage range",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 0.9,+ "typ": null,+ "max": 5,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "DC output accuracy",+ "symbol": "",+ "kind": "tolerance",+ "unit": "mV",+ "min": -2.5,+ "typ": null,+ "max": 2.5,+ "conditions": "TJ = +25°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "DC output accuracy",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -2,+ "typ": 1,+ "max": 2,+ "conditions": "VOUT + 0.3 V ≤ VIN ≤ 5.5 V, 0 mA ≤ IOUT ≤ 200 mA",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "DC output accuracy",+ "symbol": "",+ "kind": "tolerance",+ "unit": "%",+ "min": -1,+ "typ": null,+ "max": 1,+ "conditions": "VOUT + 0.3 V ≤ VIN ≤ 5.5 V, 0 mA ≤ IOUT ≤ 250 mA",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Load transient",+ "symbol": "ΔVOUT",+ "kind": "electrical",+ "unit": "mV",+ "min": -50,+ "typ": null,+ "max": 50,+ "conditions": "1 mA to 200 mA or 200 mA to 1 mA in 1 µs, COUT = 1 µF",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Load transient",+ "symbol": "ΔVOUT",+ "kind": "electrical",+ "unit": "mV",+ "min": -65,+ "typ": null,+ "max": 65,+ "conditions": "1 mA to 250 mA or 250 mA to 1 mA in 1 µs, COUT = 1 µF",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Dropout voltage",+ "symbol": "VDO",+ "kind": "electrical",+ "unit": "mV",+ "min": null,+ "typ": 130,+ "max": 200,+ "conditions": "VIN = 0.98 × VOUT(NOM), IOUT = 200 mA",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Output current limit",+ "symbol": "ICL",+ "kind": "electrical",+ "unit": "mA",+ "min": 300,+ "typ": 400,+ "max": 550,+ "conditions": "VOUT = 0.9 × VOUT(NOM)",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ground pin current",+ "symbol": "IGND",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 7.9,+ "max": 12,+ "conditions": "IOUT = 0 mA, TJ = –40°C to +125°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Shutdown current (IGND)",+ "symbol": "ISHDN",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.55,+ "max": 2,+ "conditions": "EN ≤ 0.4 V, 2.0 V < VIN ≤ 4.5 V, TJ = –40°C to +85°C",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Enable pin low (disabled)",+ "symbol": "VLO",+ "kind": "electrical",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 0.4,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Enable pin current",+ "symbol": "IEN",+ "kind": "electrical",+ "unit": "nA",+ "min": null,+ "typ": 40,+ "max": 500,+ "conditions": "EN = 5.5 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Undervoltage lock-out",+ "symbol": "UVLO",+ "kind": "electrical",+ "unit": "V",+ "min": 1.85,+ "typ": 1.9,+ "max": 1.95,+ "conditions": "VIN rising",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature",+ "symbol": "TJ",+ "kind": "electrical",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -209,4 +552,4 @@ "visibility": { "public": true }-}+}