component
TPS60120PWPR
Public Made by Adomby adom
Texas Instruments DC-DC Converters, HTSSOP-20. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
tps60120pwpr: specified limits as data (metadata.characteristics, 32 rows from the datasheet)
2 files changed
+431−1
README.md+39@@ -39,6 +39,45 @@ TPS60120PWPR from Texas Instruments, in a HTSSOP-20. Pinout and pin descriptions | Category | Power Management (PMIC) | | Pins | 21 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Input voltage (recommended operating) | VI | 1.8 | | 3.6 | V | | 8 |+| Operating junction temperature (recommended) | TJ | | | 125 | °C | | 8 |+| Input voltage range (IN, OUT, ENABLE, FB, LBI, LBO/PG) | VI | -0.3 | | 5.5 | V | | 7 |+| Continuous output current (TPS60120) | | | | 300 | mA | TPS60120, TPS60121, TPS60124, TPS60125 | 7 |+| Storage temperature range | Tstg | -55 | | 150 | °C | | 7 |+| Lead temperature | | | | 260 | °C | 1.6 mm (1/16 inch) from case for 10 s | 7 |+| Maximum junction temperature | TJ | | | 150 | °C | | 7 |+| PWP package power rating | | | | 700 | mW | TA ≤ 25°C | 8 |+| PWP package power rating | | | | 448 | mW | TA = 70°C | 8 |+| PWP package power rating | | | | 364 | mW | TA = 85°C | 8 |+| PWP package power rating (case) | | | | 25 | mW | TC ≤ 62.5°C | 8 |+| PWP package power rating (case) | | | | 22.9 | mW | TC = 70°C | 8 |+| PWP package power rating (case) | | | | 18.5 | mW | TC = 85°C | 8 |+| Output voltage | VO | 3.17 | | 3.43 | V | TPS60120; 1.8 V < VI < 2 V, 0 < IO < IO(max)/2, TC = 0°C to 70°C | 9 |+| Internal switching frequency | fOSC(INT) | 210 | 320 | 450 | kHz | VI = 2.4 V | 9 |+| Quiescent current (no-load input current) | IQ | | 55 | 90 | µA | VI = 2.4 V | 9 |+| Shutdown supply current | IQ(SDN) | | 0.05 | 1 | µA | VI = 2.4 V, V(ENABLE) = 0 V | 9 |+| Output leakage current | Ilkg(OUT) | | | 1 | µA | VI = 2.4 V, V(ENABLE) = 0 V | 9 |+| Enable input leakage current | Ilkg(ENABLE) | | 0.01 | 0.1 | µA | V(ENABLE) = VGND or VI | 9 |+| Input undervoltage lockout threshold | V(UVLO) | 1.6 | | 1.8 | V | TC = 25°C | 9 |+| Maximum continuous output current (TPS60120) | IO(MAX) | | | 200 | mA | TPS60120, TPS60121, TPS60124, TPS60125 | 9 |+| Low battery trip voltage (TPS60120) | V(LBITRIP) | 1.15 | 1.21 | 1.27 | V | VI = 1.8 V to 2.2 V, hysteresis 0.8% for rising LBI, TC = 0°C to 70°C | 9 |+| LBI input current (TPS60120) | II(LBI) | | | 100 | nA | V(LBI) = 1.3 V | 9 |+| LBO output voltage low (TPS60120) | VO(LBO) | | | 0.4 | V | V(LBI) = 0 V, I(LBO,SINK) = 1 mA | 9 |+| LBO leakage current (TPS60120) | Ilkg(LBO) | | 0.01 | 0.1 | µA | V(LBI) = 1.3 V, V(LBO) = 3.3 V | 9 |+| Short circuit current limit | | | 115 | | mA | VI < 2.4 V, VO = 0 V, TC = 25°C | 9 |+| Output load regulation | | | 0.003 | | %/mA | VI = 2.4 V, 1 mA < IO < IO(MAX), TC = 25°C | 9 |+| Output line regulation | | | 0.3 | | %/V | 2 V < VI < 3.3 V, IO = 100 mA, TC = 25°C | 9 |+| Junction-to-ambient thermal resistance | RθJA | | 178 | | °C/W | PWP package | 8 |+| Junction-to-case thermal resistance | RθJC | | 3.5 | | °C/W | PWP package, exposed thermal pad coupled to infinite heat sink | 8 |+| Power dissipation derating factor above TA = 25°C | | | 5.6 | | mW/°C | PWP package | 8 |+| Power dissipation derating factor above TC = 62.5°C | | | 285.7 | | mW/°C | PWP package | 8 |+ ## CAD (KiCad official) - Symbol: `TPS60120PWPR`
page.json+392−1@@ -259,6 +259,397 @@ "Package": "HTSSOP-20", "Category": "Power Management (PMIC)", "Pins": "21"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "b856c851bfa4d9f6",+ "rows": [+ {+ "name": "Input voltage (recommended operating)",+ "symbol": "VI",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 1.8,+ "typ": null,+ "max": 3.6,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Operating junction temperature (recommended)",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Input voltage range (IN, OUT, ENABLE, FB, LBI, LBO/PG)",+ "symbol": "VI",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 5.5,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Continuous output current (TPS60120)",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 300,+ "conditions": "TPS60120, TPS60121, TPS60124, TPS60125",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Storage temperature range",+ "symbol": "Tstg",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": -55,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Lead temperature",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 260,+ "conditions": "1.6 mm (1/16 inch) from case for 10 s",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Maximum junction temperature",+ "symbol": "TJ",+ "kind": "absolute_maximum",+ "unit": "°C",+ "min": null,+ "typ": null,+ "max": 150,+ "conditions": "",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 700,+ "conditions": "TA ≤ 25°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 448,+ "conditions": "TA = 70°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 364,+ "conditions": "TA = 85°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating (case)",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 25,+ "conditions": "TC ≤ 62.5°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating (case)",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 22.9,+ "conditions": "TC = 70°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "PWP package power rating (case)",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW",+ "min": null,+ "typ": null,+ "max": 18.5,+ "conditions": "TC = 85°C",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Output voltage",+ "symbol": "VO",+ "kind": "electrical",+ "unit": "V",+ "min": 3.17,+ "typ": null,+ "max": 3.43,+ "conditions": "TPS60120; 1.8 V < VI < 2 V, 0 < IO < IO(max)/2, TC = 0°C to 70°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Internal switching frequency",+ "symbol": "fOSC(INT)",+ "kind": "electrical",+ "unit": "kHz",+ "min": 210,+ "typ": 320,+ "max": 450,+ "conditions": "VI = 2.4 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Quiescent current (no-load input current)",+ "symbol": "IQ",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 55,+ "max": 90,+ "conditions": "VI = 2.4 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Shutdown supply current",+ "symbol": "IQ(SDN)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.05,+ "max": 1,+ "conditions": "VI = 2.4 V, V(ENABLE) = 0 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Output leakage current",+ "symbol": "Ilkg(OUT)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "VI = 2.4 V, V(ENABLE) = 0 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Enable input leakage current",+ "symbol": "Ilkg(ENABLE)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.01,+ "max": 0.1,+ "conditions": "V(ENABLE) = VGND or VI",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Input undervoltage lockout threshold",+ "symbol": "V(UVLO)",+ "kind": "electrical",+ "unit": "V",+ "min": 1.6,+ "typ": null,+ "max": 1.8,+ "conditions": "TC = 25°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Maximum continuous output current (TPS60120)",+ "symbol": "IO(MAX)",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": null,+ "max": 200,+ "conditions": "TPS60120, TPS60121, TPS60124, TPS60125",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Low battery trip voltage (TPS60120)",+ "symbol": "V(LBITRIP)",+ "kind": "electrical",+ "unit": "V",+ "min": 1.15,+ "typ": 1.21,+ "max": 1.27,+ "conditions": "VI = 1.8 V to 2.2 V, hysteresis 0.8% for rising LBI, TC = 0°C to 70°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "LBI input current (TPS60120)",+ "symbol": "II(LBI)",+ "kind": "electrical",+ "unit": "nA",+ "min": null,+ "typ": null,+ "max": 100,+ "conditions": "V(LBI) = 1.3 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "LBO output voltage low (TPS60120)",+ "symbol": "VO(LBO)",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": null,+ "max": 0.4,+ "conditions": "V(LBI) = 0 V, I(LBO,SINK) = 1 mA",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "LBO leakage current (TPS60120)",+ "symbol": "Ilkg(LBO)",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.01,+ "max": 0.1,+ "conditions": "V(LBI) = 1.3 V, V(LBO) = 3.3 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Short circuit current limit",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 115,+ "max": null,+ "conditions": "VI < 2.4 V, VO = 0 V, TC = 25°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Output load regulation",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/mA",+ "min": null,+ "typ": 0.003,+ "max": null,+ "conditions": "VI = 2.4 V, 1 mA < IO < IO(MAX), TC = 25°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Output line regulation",+ "symbol": "",+ "kind": "electrical",+ "unit": "%/V",+ "min": null,+ "typ": 0.3,+ "max": null,+ "conditions": "2 V < VI < 3.3 V, IO = 100 mA, TC = 25°C",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 178,+ "max": null,+ "conditions": "PWP package",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case thermal resistance",+ "symbol": "RθJC",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 3.5,+ "max": null,+ "conditions": "PWP package, exposed thermal pad coupled to infinite heat sink",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Power dissipation derating factor above TA = 25°C",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW/°C",+ "min": null,+ "typ": 5.6,+ "max": null,+ "conditions": "PWP package",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Power dissipation derating factor above TC = 62.5°C",+ "symbol": "",+ "kind": "thermal",+ "unit": "mW/°C",+ "min": null,+ "typ": 285.7,+ "max": null,+ "conditions": "PWP package",+ "source_page": 8,+ "source": "datasheet"+ }+ ] } }, "variants": [],@@ -300,4 +691,4 @@ "visibility": { "public": true }-}+}