← Commit history

tps51222rtvr: specified limits as data (metadata.characteristics, 60 rows from the datasheet)

Ray ·3ec13b2ed7 ·17d ago ·parent cef57b4
2 files changed +795−1
README.md+67
@@ -51,6 +51,73 @@ TPS51222RTVR from Texas Instruments, in a WQFN-32-EP(5x5). Pinout and pin descri | Category | Power Management (PMIC) | | Pins | 33 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| VIN shutdown current | I(VINSDN) |  | 7 | 15 | µA | TA = 25°C, No Load, EN = 0V, V5SW = 0 V | 4 |+| VIN standby current | I(VINSTBY) |  | 80 | 120 | µA | TA = 25°C, No Load, EN1 = EN2 = V5SW = 0 V | 4 |+| VREF2 output voltage | V(VREF2) | 1.98 | 2 | 2.02 | V | I(VREF2) < ±10 µA, TA = 25°C | 4 |+| VREG3 output voltage | V(VREG3) | 3.279 | 3.313 | 3.347 | V | V5SW = 0 V, I(VREG3) = 0 mA, TA = 25°C | 4 |+| VREG3 output voltage | V(VREG3) | 3.135 | 3.3 | 3.4 | V | V5SW = 0 V, 0 mA < I(VREG3) < 10 mA, 5.5 V < VIN < 32 V | 4 |+| VREG3 output current | I(VREG3) | 10 | 15 | 20 | mA | VREG3 = 3 V | 4 |+| VREG5 output voltage | V(VREG5) | 4.99 | 5.04 | 5.09 | V | V5SW = 0 V, I(VREG5) = 0 mA, TA = 25°C | 4 |+| VREG5 output voltage | V(VREG5) | 4.9 | 5.03 | 5.15 | V | V5SW = 0 V, 0 mA < I(VREG5) < 100 mA, 6 V < VIN < 32 V | 4 |+| VREG5 output voltage | V(VREG5) | 4.5 | 5.03 | 5.15 | V | V5SW = 0 V, 0 mA < I(VREG5) < 100 mA, 5.5 V < VIN < 32 V | 4 |+| VREG5 output current | I(VREG5) | 100 | 150 | 200 | mA | V5SW = 0 V, VREG5 = 4.5 V | 4 |+| VREG5 output current (V5SW supplied) | I(VREG5) | 200 | 300 | 400 | mA | V5SW = 5 V, VREG5 = 4.5 V | 4 |+| Switchover threshold | V(THV5SW) | 4.55 | 4.7 | 4.8 | V | Turning on | 4 |+| VFB regulation voltage | V(VFB) | 0.9925 | 1 | 1.0075 | V | TA = 25°C, No Load | 4 |+| VFB regulation voltage over temperature | V(VFB) | 0.99 | 1 | 1.01 | V | TA = –40°C to 85°C, No Load | 4 |+| VFB input current | I(VFB) | -50 |  | 50 | nA | VFBx = 1.05 V, COMPx = 1.8 V, TA = 25°C | 4 |+| COMP clamp voltage | VCOMP | 2.18 | 2.22 | 2.26 | V |  | 4 |+| COMP negative clamp voltage | VCOMPN | 1.73 | 1.77 | 1.81 | V |  | 4 |+| PG threshold, PG in from lower | V(THPG) | 92.5 | 95 | 97.5 | % | PG in from lower | 5 |+| PG threshold, PG in from higher | V(THPG) | 102.5 | 105 | 107.5 | % | PG in from higher | 5 |+| PGOOD delay | t(PGDLY) | 0.8 | 1 | 1.2 | ms | Delay for PG in | 5 |+| Switching frequency | f(SW) | 273 | 303 | 333 | kHz | Rf = 330 kΩ | 5 |+| RF threshold | V(THRF) | 0.7 | 1.3 | 2 | V | Lo to Hi | 5 |+| DRVH-off to DRVL-on dead time | tD | 10 | 30 | 50 | ns | DRVH-off to DRVL-on | 5 |+| Current limit threshold | V(OCL) | 55 | 60 | 68 | mV | 2 V < VCSNx < 12.6 V, TA = –40 to 85°C | 5 |+| Current limit threshold | V(OCL) | 54 | 60 | 72 | mV | 0.95 V < VCSNx < 12.6 V, TA = –40 to 85°C | 5 |+| Negative current limit threshold | V(OCLN-LV) | -77 | -60 | -49 | mV | 0.95 V < VCSNx < 12.6 V, TA = –40 to 85°C | 5 |+| EN1/EN2 threshold | V(EN12) | 0.45 | 0.5 | 0.55 | V | Wake up | 6 |+| Current monitor output voltage | V(IMON) | 2.75 | 3 | 3.25 | V | VCSPx–VCSNx = 60 mV, 0.95 V < VCSNx < 12.6 V, TA = 25°C | 6 |+| OVP trip threshold | V(OVP) | 110 | 115 | 120 | % | OVP detect | 6 |+| UVP trip threshold | V(UVP) | 65 | 70 | 73 | % | UVP detect | 6 |+| VREG5 UVLO threshold | V(UVREG5) | 4.1 | 4.2 | 4.3 | V | Wake up | 6 |+| VREG3 UVLO threshold | V(UVREG3) | 3 | 3.1 | 3.2 | V | Wake up | 6 |+| EN threshold | V(EN) | 0.8 | 1 | 1.2 | V | Wake up | 6 |+| Input voltage range | VIN | -0.3 |  | 34 | V |  | 3 |+| Boot voltage range | VBST1, VBST2 | -0.3 |  | 39 | V |  | 3 |+| Boot voltage range wrt SW | VBST1, VBST2 | -0.3 |  | 7 | V | Voltage with respect to the corresponding SW terminal | 3 |+| Switch node voltage range | SW1, SW2 | -5 |  | 34 | V |  | 3 |+| Current sense input voltage range | CSN1, CSN2, CSP1, CSP2 | -1 |  | 13.5 | V |  | 3 |+| Logic input voltage range | EN, EN1, EN2, SKIPSEL1, SKIPSEL2, VFB1, VFB2 | -0.3 |  | 7 | V |  | 3 |+| V5SW voltage range | V5SW | -1 |  | 7 | V |  | 3 |+| V5SW voltage range to VREG5 | V5SW (to VREG5) | -7 |  | 7 | V | When EN is high and V5SW is grounded, or voltage is applied to V5SW when EN is low | 3 |+| High-side gate driver voltage range | DRVH1, DRVH2 | -5 |  | 39 | V |  | 3 |+| High-side gate driver voltage range wrt SW | DRVH1, DRVH2 | -0.3 |  | 7 | V | Voltage with respect to the corresponding SW terminal | 3 |+| Output and logic I/O voltage range | COMP1, COMP2, DRVL1, DRVL2, IMON1, IMON2, PGOOD1, PGOOD2, RF, VREF2, VREG5 | -0.3 |  | 7 | V |  | 3 |+| VREG3 voltage range | VREG3 | -0.3 |  | 3.6 | V |  | 3 |+| Junction temperature | TJ |  |  | 150 | °C |  | 3 |+| Storage temperature | Tstg | -55 |  | 150 | °C |  | 3 |+| Input voltage supply | VIN | 4.5 |  | 32 | V |  | 3 |+| V5SW voltage | V5SW | -0.8 |  | 6 | V |  | 3 |+| Boot voltage | VBST1, VBST2 | -0.1 |  | 37 | V |  | 3 |+| High-side gate driver voltage | DRVH1, DRVH2 | -4 |  | 37 | V |  | 3 |+| High-side gate driver voltage wrt SW | DRVH1, DRVH2 (wrt SW1, 2) | -0.1 |  | 6 | V |  | 3 |+| Switch node voltage | SW1, SW2 | -4 |  | 32 | V |  | 3 |+| Current sense input voltage | CSP1, CSP2, CSN1, CSN2 | -0.8 |  | 13 | V |  | 3 |+| Logic and I/O voltage | COMP1, COMP2, DRVL1, DRVL2, EN, EN1, EN2, IMON1, IMON2, PGOOD1, PGOOD2, RF, SKIPSEL1, SKIPSEL2, VFB1, VFB2, VREF2, VREG5 | -0.1 |  | 6 | V |  | 3 |+| VREG3 voltage | VREG3 | -0.1 |  | 3.5 | V |  | 3 |+| Operating free-air temperature | TA | -40 |  | 85 | °C |  | 3 |+| Power rating, 32-pin RTV | PD |  |  | 1.7 | W | TA < 25°C | 3 |+| Power rating, 32-pin RTV at TA = 85°C | PD |  |  | 0.7 | W | TA = 85°C | 3 |+| Derating factor, 32-pin RTV |  |  | 17 |  | mW/°C | Above TA = 25°C | 3 |+ ## CAD (KiCad official)  - Symbol: `TPS51222RTVR`
page.json+728−1
@@ -331,6 +331,733 @@       "Package": "WQFN-32-EP(5x5)",       "Category": "Power Management (PMIC)",       "Pins": "33"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "287579365d9552a4",+      "rows": [+        {+          "name": "VIN shutdown current",+          "symbol": "I(VINSDN)",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 7,+          "max": 15,+          "conditions": "TA = 25°C, No Load, EN = 0V, V5SW = 0 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VIN standby current",+          "symbol": "I(VINSTBY)",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": 80,+          "max": 120,+          "conditions": "TA = 25°C, No Load, EN1 = EN2 = V5SW = 0 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREF2 output voltage",+          "symbol": "V(VREF2)",+          "kind": "electrical",+          "unit": "V",+          "min": 1.98,+          "typ": 2,+          "max": 2.02,+          "conditions": "I(VREF2) < ±10 µA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG3 output voltage",+          "symbol": "V(VREG3)",+          "kind": "electrical",+          "unit": "V",+          "min": 3.279,+          "typ": 3.313,+          "max": 3.347,+          "conditions": "V5SW = 0 V, I(VREG3) = 0 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG3 output voltage",+          "symbol": "V(VREG3)",+          "kind": "electrical",+          "unit": "V",+          "min": 3.135,+          "typ": 3.3,+          "max": 3.4,+          "conditions": "V5SW = 0 V, 0 mA < I(VREG3) < 10 mA, 5.5 V < VIN < 32 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG3 output current",+          "symbol": "I(VREG3)",+          "kind": "electrical",+          "unit": "mA",+          "min": 10,+          "typ": 15,+          "max": 20,+          "conditions": "VREG3 = 3 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output voltage",+          "symbol": "V(VREG5)",+          "kind": "electrical",+          "unit": "V",+          "min": 4.99,+          "typ": 5.04,+          "max": 5.09,+          "conditions": "V5SW = 0 V, I(VREG5) = 0 mA, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output voltage",+          "symbol": "V(VREG5)",+          "kind": "electrical",+          "unit": "V",+          "min": 4.9,+          "typ": 5.03,+          "max": 5.15,+          "conditions": "V5SW = 0 V, 0 mA < I(VREG5) < 100 mA, 6 V < VIN < 32 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output voltage",+          "symbol": "V(VREG5)",+          "kind": "electrical",+          "unit": "V",+          "min": 4.5,+          "typ": 5.03,+          "max": 5.15,+          "conditions": "V5SW = 0 V, 0 mA < I(VREG5) < 100 mA, 5.5 V < VIN < 32 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output current",+          "symbol": "I(VREG5)",+          "kind": "electrical",+          "unit": "mA",+          "min": 100,+          "typ": 150,+          "max": 200,+          "conditions": "V5SW = 0 V, VREG5 = 4.5 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VREG5 output current (V5SW supplied)",+          "symbol": "I(VREG5)",+          "kind": "electrical",+          "unit": "mA",+          "min": 200,+          "typ": 300,+          "max": 400,+          "conditions": "V5SW = 5 V, VREG5 = 4.5 V",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "Switchover threshold",+          "symbol": "V(THV5SW)",+          "kind": "electrical",+          "unit": "V",+          "min": 4.55,+          "typ": 4.7,+          "max": 4.8,+          "conditions": "Turning on",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB regulation voltage",+          "symbol": "V(VFB)",+          "kind": "tolerance",+          "unit": "V",+          "min": 0.9925,+          "typ": 1,+          "max": 1.0075,+          "conditions": "TA = 25°C, No Load",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB regulation voltage over temperature",+          "symbol": "V(VFB)",+          "kind": "tolerance",+          "unit": "V",+          "min": 0.99,+          "typ": 1,+          "max": 1.01,+          "conditions": "TA = –40°C to 85°C, No Load",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "VFB input current",+          "symbol": "I(VFB)",+          "kind": "electrical",+          "unit": "nA",+          "min": -50,+          "typ": null,+          "max": 50,+          "conditions": "VFBx = 1.05 V, COMPx = 1.8 V, TA = 25°C",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "COMP clamp voltage",+          "symbol": "VCOMP",+          "kind": "electrical",+          "unit": "V",+          "min": 2.18,+          "typ": 2.22,+          "max": 2.26,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "COMP negative clamp voltage",+          "symbol": "VCOMPN",+          "kind": "electrical",+          "unit": "V",+          "min": 1.73,+          "typ": 1.77,+          "max": 1.81,+          "conditions": "",+          "source_page": 4,+          "source": "datasheet"+        },+        {+          "name": "PG threshold, PG in from lower",+          "symbol": "V(THPG)",+          "kind": "electrical",+          "unit": "%",+          "min": 92.5,+          "typ": 95,+          "max": 97.5,+          "conditions": "PG in from lower",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "PG threshold, PG in from higher",+          "symbol": "V(THPG)",+          "kind": "electrical",+          "unit": "%",+          "min": 102.5,+          "typ": 105,+          "max": 107.5,+          "conditions": "PG in from higher",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "PGOOD delay",+          "symbol": "t(PGDLY)",+          "kind": "electrical",+          "unit": "ms",+          "min": 0.8,+          "typ": 1,+          "max": 1.2,+          "conditions": "Delay for PG in",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Switching frequency",+          "symbol": "f(SW)",+          "kind": "electrical",+          "unit": "kHz",+          "min": 273,+          "typ": 303,+          "max": 333,+          "conditions": "Rf = 330 kΩ",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "RF threshold",+          "symbol": "V(THRF)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.7,+          "typ": 1.3,+          "max": 2,+          "conditions": "Lo to Hi",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "DRVH-off to DRVL-on dead time",+          "symbol": "tD",+          "kind": "timing",+          "unit": "ns",+          "min": 10,+          "typ": 30,+          "max": 50,+          "conditions": "DRVH-off to DRVL-on",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold",+          "symbol": "V(OCL)",+          "kind": "electrical",+          "unit": "mV",+          "min": 55,+          "typ": 60,+          "max": 68,+          "conditions": "2 V < VCSNx < 12.6 V, TA = –40 to 85°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Current limit threshold",+          "symbol": "V(OCL)",+          "kind": "electrical",+          "unit": "mV",+          "min": 54,+          "typ": 60,+          "max": 72,+          "conditions": "0.95 V < VCSNx < 12.6 V, TA = –40 to 85°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "Negative current limit threshold",+          "symbol": "V(OCLN-LV)",+          "kind": "electrical",+          "unit": "mV",+          "min": -77,+          "typ": -60,+          "max": -49,+          "conditions": "0.95 V < VCSNx < 12.6 V, TA = –40 to 85°C",+          "source_page": 5,+          "source": "datasheet"+        },+        {+          "name": "EN1/EN2 threshold",+          "symbol": "V(EN12)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.45,+          "typ": 0.5,+          "max": 0.55,+          "conditions": "Wake up",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Current monitor output voltage",+          "symbol": "V(IMON)",+          "kind": "electrical",+          "unit": "V",+          "min": 2.75,+          "typ": 3,+          "max": 3.25,+          "conditions": "VCSPx–VCSNx = 60 mV, 0.95 V < VCSNx < 12.6 V, TA = 25°C",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "OVP trip threshold",+          "symbol": "V(OVP)",+          "kind": "electrical",+          "unit": "%",+          "min": 110,+          "typ": 115,+          "max": 120,+          "conditions": "OVP detect",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "UVP trip threshold",+          "symbol": "V(UVP)",+          "kind": "electrical",+          "unit": "%",+          "min": 65,+          "typ": 70,+          "max": 73,+          "conditions": "UVP detect",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "VREG5 UVLO threshold",+          "symbol": "V(UVREG5)",+          "kind": "electrical",+          "unit": "V",+          "min": 4.1,+          "typ": 4.2,+          "max": 4.3,+          "conditions": "Wake up",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "VREG3 UVLO threshold",+          "symbol": "V(UVREG3)",+          "kind": "electrical",+          "unit": "V",+          "min": 3,+          "typ": 3.1,+          "max": 3.2,+          "conditions": "Wake up",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "EN threshold",+          "symbol": "V(EN)",+          "kind": "electrical",+          "unit": "V",+          "min": 0.8,+          "typ": 1,+          "max": 1.2,+          "conditions": "Wake up",+          "source_page": 6,+          "source": "datasheet"+        },+        {+          "name": "Input voltage range",+          "symbol": "VIN",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 34,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Boot voltage range",+          "symbol": "VBST1, VBST2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 39,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Boot voltage range wrt SW",+          "symbol": "VBST1, VBST2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "Voltage with respect to the corresponding SW terminal",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Switch node voltage range",+          "symbol": "SW1, SW2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": 34,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Current sense input voltage range",+          "symbol": "CSN1, CSN2, CSP1, CSP2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -1,+          "typ": null,+          "max": 13.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Logic input voltage range",+          "symbol": "EN, EN1, EN2, SKIPSEL1, SKIPSEL2, VFB1, VFB2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "V5SW voltage range",+          "symbol": "V5SW",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -1,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "V5SW voltage range to VREG5",+          "symbol": "V5SW (to VREG5)",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -7,+          "typ": null,+          "max": 7,+          "conditions": "When EN is high and V5SW is grounded, or voltage is applied to V5SW when EN is low",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-side gate driver voltage range",+          "symbol": "DRVH1, DRVH2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -5,+          "typ": null,+          "max": 39,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-side gate driver voltage range wrt SW",+          "symbol": "DRVH1, DRVH2",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "Voltage with respect to the corresponding SW terminal",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Output and logic I/O voltage range",+          "symbol": "COMP1, COMP2, DRVL1, DRVL2, IMON1, IMON2, PGOOD1, PGOOD2, RF, VREF2, VREG5",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 7,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "VREG3 voltage range",+          "symbol": "VREG3",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": -0.3,+          "typ": null,+          "max": 3.6,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Junction temperature",+          "symbol": "TJ",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Storage temperature",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -55,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Input voltage supply",+          "symbol": "VIN",+          "kind": "recommended_operating",+          "unit": "V",+          "min": 4.5,+          "typ": null,+          "max": 32,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "V5SW voltage",+          "symbol": "V5SW",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.8,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Boot voltage",+          "symbol": "VBST1, VBST2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 37,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-side gate driver voltage",+          "symbol": "DRVH1, DRVH2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -4,+          "typ": null,+          "max": 37,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "High-side gate driver voltage wrt SW",+          "symbol": "DRVH1, DRVH2 (wrt SW1, 2)",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Switch node voltage",+          "symbol": "SW1, SW2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -4,+          "typ": null,+          "max": 32,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Current sense input voltage",+          "symbol": "CSP1, CSP2, CSN1, CSN2",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.8,+          "typ": null,+          "max": 13,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Logic and I/O voltage",+          "symbol": "COMP1, COMP2, DRVL1, DRVL2, EN, EN1, EN2, IMON1, IMON2, PGOOD1, PGOOD2, RF, SKIPSEL1, SKIPSEL2, VFB1, VFB2, VREF2, VREG5",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 6,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "VREG3 voltage",+          "symbol": "VREG3",+          "kind": "recommended_operating",+          "unit": "V",+          "min": -0.1,+          "typ": null,+          "max": 3.5,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Operating free-air temperature",+          "symbol": "TA",+          "kind": "recommended_operating",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 85,+          "conditions": "",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Power rating, 32-pin RTV",+          "symbol": "PD",+          "kind": "thermal",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1.7,+          "conditions": "TA < 25°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Power rating, 32-pin RTV at TA = 85°C",+          "symbol": "PD",+          "kind": "thermal",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 0.7,+          "conditions": "TA = 85°C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Derating factor, 32-pin RTV",+          "symbol": "",+          "kind": "thermal",+          "unit": "mW/°C",+          "min": null,+          "typ": 17,+          "max": null,+          "conditions": "Above TA = 25°C",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],@@ -372,4 +1099,4 @@   "visibility": {     "public": true   }-}\ No newline at end of file+}