← Commit history
page.json+8−5@@ -53,7 +53,7 @@ "number": "1", "name": "UV", "type": "tri_state",- "description": "Active-low open-drain undervoltage output; asserts low when SENSE voltage falls below internal threshold VIT-(UV); requires pull-up resistor (2.2k\u03a9 to 10M\u03a9) to voltage up to 18V."+ "description": "Active-low open-drain undervoltage output; asserts low when SENSE voltage falls below internal threshold VIT-(UV); requires pull-up resistor (2.2kΩ to 10MΩ) to voltage up to 18V." }, { "number": "2",@@ -71,19 +71,19 @@ "number": "4", "name": "SET", "type": "input",- "description": "Configuration input; SET voltage \u2264 VIL(set) 250mV selects wider accuracy band; SET voltage \u2265 VIH(set) 750mV selects tighter accuracy band."+ "description": "Configuration input; SET voltage ≤ VIL(set) 250mV selects wider accuracy band; SET voltage ≥ VIH(set) 750mV selects tighter accuracy band." }, { "number": "5", "name": "VDD", "type": "power_in",- "description": "Power supply input (2V to 18V); decouple to GND with 0.1\u03bcF ceramic capacitor per good analog design practice."+ "description": "Power supply input (2V to 18V); decouple to GND with 0.1μF ceramic capacitor per good analog design practice." }, { "number": "6", "name": "OV", "type": "tri_state",- "description": "Active-low open-drain overvoltage output; asserts low when SENSE voltage exceeds internal threshold VIT+(OV); requires pull-up resistor (2.2k\u03a9 to 10M\u03a9) to voltage up to 18V."+ "description": "Active-low open-drain overvoltage output; asserts low when SENSE voltage exceeds internal threshold VIT+(OV); requires pull-up resistor (2.2kΩ to 10MΩ) to voltage up to 18V." } ], "provenance": {@@ -161,5 +161,8 @@ "docs/tps3702cx50ddcr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }