← Commit history
package.json+939−4@@ -1,6 +1,6 @@ { "slug": "tps23752pwp",- "version": "0.1.0",+ "version": "0.1.1", "type": "component", "description": "Texas Instruments Power Over Ethernet Controllers, HTSSOP-20. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.", "tags": [@@ -29,7 +29,8 @@ "viewers/footprint.html", "tps23752pwp-hero.glb", "tps23752pwp-hero.overlay.json",- "tps23752pwp-etched.glb"+ "tps23752pwp-etched.glb",+ "tps23752pwp-etched.step" ], "component": { "mpn": "TPS23752PWP",@@ -43,7 +44,7 @@ "symbol": "tps23752pwp.kicad_sym", "footprint": "tps23752pwp.kicad_mod", "model_3d": "tps23752pwp-hero.glb",- "model_3d_plain": "tps23752pwp-etched.glb",+ "model_3d_plain": "tps23752pwp.glb", "model_3d_step": "tps23752pwp-etched.step", "model_3d_step_plain": "tps23752pwp.step", "lbr": "tps23752pwp.lbr"@@ -269,5 +270,939 @@ "checked_by": "factory/step_pose.py (Z-up, origin, seat, binding)" } ]- }+ },+ "title": "TPS23752PWP",+ "brief": "Texas Instruments Power Over Ethernet Controllers, HTSSOP-20. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "metadata": {+ "specs": {+ "Manufacturer": "Texas Instruments",+ "Package": "HTSSOP-20",+ "Category": "Power Supply Chip",+ "Pins": "21"+ },+ "characteristics": {+ "version": 1,+ "source": "datasheet",+ "datasheet_sha256": "2fb0832c6e38a7d1d76a574e7746de0755586c6a0e57ccc0ae59d27f9b42f1ea",+ "rows": [+ {+ "name": "Input voltage ARTN, RTN, VDD",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 57,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Input voltage LED, APD, SRD, T2P, VC to ARTN",+ "symbol": "",+ "kind": "recommended_operating",+ "unit": "V",+ "min": 0,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction temperature",+ "symbol": "TJ",+ "kind": "recommended_operating",+ "unit": "°C",+ "min": -40,+ "typ": null,+ "max": 125,+ "conditions": "",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Absolute max DEN, VDD",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 100,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Absolute max ARTN, RTN",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.6,+ "typ": null,+ "max": 100,+ "conditions": "RTN with IRTN = 0",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Absolute max CLS",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 6.5,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Absolute max LED, APD, SRD, T2P, VC to ARTN",+ "symbol": "",+ "kind": "absolute_maximum",+ "unit": "V",+ "min": -0.3,+ "typ": null,+ "max": 18,+ "conditions": "",+ "source_page": 4,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-ambient thermal resistance",+ "symbol": "RθJA",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 38.5,+ "max": null,+ "conditions": "PWP 20 pins",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (top) thermal resistance",+ "symbol": "RθJC(top)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 23.8,+ "max": null,+ "conditions": "PWP 20 pins",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-board thermal resistance",+ "symbol": "RθJB",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 25.6,+ "max": null,+ "conditions": "PWP 20 pins",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "Junction-to-case (bottom) thermal resistance",+ "symbol": "RθJC(bot)",+ "kind": "thermal",+ "unit": "°C/W",+ "min": null,+ "typ": 1.6,+ "max": null,+ "conditions": "PWP 20 pins",+ "source_page": 5,+ "source": "datasheet"+ },+ {+ "name": "VC output voltage in sleep mode",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 12,+ "typ": 12.8,+ "max": 13.8,+ "conditions": "VVDD = 48 V, Sleep mode",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VC startup source current",+ "symbol": "IVC_ST",+ "kind": "electrical",+ "unit": "mA",+ "min": 1.1,+ "typ": 1.5,+ "max": 2.1,+ "conditions": "VVDD = 48 V, VC = 0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VC startup source current",+ "symbol": "IVC_ST",+ "kind": "electrical",+ "unit": "mA",+ "min": 0.9,+ "typ": 1.3,+ "max": 1.8,+ "conditions": "VVDD = 10.9 V, VC = 8.6 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VC operating current",+ "symbol": "IVC_OP",+ "kind": "electrical",+ "unit": "mA",+ "min": 0.9,+ "typ": 1.8,+ "max": 3,+ "conditions": "VVC = 12 V, VCTL = VB",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Bootstrap start up time",+ "symbol": "tST",+ "kind": "timing",+ "unit": "ms",+ "min": 103,+ "typ": 155,+ "max": 203,+ "conditions": "CVC = 22 µF, VVDD = 48 V, VVC (0) → VCUV",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VC UVLO threshold",+ "symbol": "VCUV",+ "kind": "electrical",+ "unit": "V",+ "min": 8.6,+ "typ": 8.9,+ "max": 9.2,+ "conditions": "VVC rising until VSRD ↓",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VC UVLO hysteresis",+ "symbol": "VCUVH",+ "kind": "electrical",+ "unit": "V",+ "min": 3,+ "typ": 3.2,+ "max": 3.4,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VB output voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 4.75,+ "typ": 5,+ "max": 5.25,+ "conditions": "7.5 V ≤ VVC ≤ 18 V, 0 ≤ IVB ≤ 5 mA",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "APD threshold voltage",+ "symbol": "VAPDEN",+ "kind": "electrical",+ "unit": "V",+ "min": 1.43,+ "typ": 1.5,+ "max": 1.57,+ "conditions": "VAPD ↑, with respect to ARTN",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "APD hysteresis",+ "symbol": "VAPDH",+ "kind": "electrical",+ "unit": "V",+ "min": 0.28,+ "typ": 0.3,+ "max": 0.32,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "APD leakage current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "VAPD = 18 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency in PWM mode",+ "symbol": "FSW",+ "kind": "electrical",+ "unit": "kHz",+ "min": 226,+ "typ": 251,+ "max": 276,+ "conditions": "RT = 34.0 kΩ. Measure at GATE",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Switching frequency in VFO mode",+ "symbol": "FVFO",+ "kind": "electrical",+ "unit": "kHz",+ "min": 105,+ "typ": 135,+ "max": 165,+ "conditions": "VCTL = 1.75 V, RT = 34.0 kΩ. Measure at GATE",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Maximum duty cycle",+ "symbol": "DMAX",+ "kind": "electrical",+ "unit": "%",+ "min": 75,+ "typ": 80,+ "max": 85,+ "conditions": "VCTL = VB, Measure at GATE",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCTL at PWM/VFO transition",+ "symbol": "VCTL_VFO",+ "kind": "electrical",+ "unit": "V",+ "min": 1.9,+ "typ": 2,+ "max": 2.1,+ "conditions": "VSRT = 0.5 V, VCTL ↓ until VSRD↑",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "VCTL at PWM/VFO transition",+ "symbol": "VCTL_VFO",+ "kind": "electrical",+ "unit": "V",+ "min": 2.15,+ "typ": 2.25,+ "max": 2.35,+ "conditions": "VSRT = 1.0 V, VCTL ↓ until VSRD↑",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Internal soft start delay time",+ "symbol": "TSSD",+ "kind": "timing",+ "unit": "ms",+ "min": 1.87,+ "typ": 3.01,+ "max": 5.09,+ "conditions": "VCTL = 3.5 V, measure from switching start to VCSMAX",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CTL input resistance",+ "symbol": "",+ "kind": "electrical",+ "unit": "kΩ",+ "min": 70,+ "typ": 105,+ "max": 145,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Zero frequency threshold",+ "symbol": "VZF",+ "kind": "electrical",+ "unit": "V",+ "min": 1.4,+ "typ": 1.5,+ "max": 1.6,+ "conditions": "VCTL ↓ until GATE stops switching",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Zero duty cycle threshold",+ "symbol": "VZDC",+ "kind": "electrical",+ "unit": "V",+ "min": 1.55,+ "typ": 1.75,+ "max": 1.95,+ "conditions": "VSRT = VARTN, VCTL ↓ until GATE stops switching",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CS maximum threshold voltage",+ "symbol": "VCSMAX",+ "kind": "electrical",+ "unit": "V",+ "min": 0.22,+ "typ": 0.25,+ "max": 0.28,+ "conditions": "VCS↑ until VGATE ↓",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Peak VCS in VFO mode",+ "symbol": "VCS_VFO",+ "kind": "electrical",+ "unit": "mV",+ "min": 40,+ "typ": 50,+ "max": 60,+ "conditions": "1.60 V ≤ VCTL ≤ 1.90 V, VSRT = 0.5 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Peak VCS in VFO mode",+ "symbol": "VCS_VFO",+ "kind": "electrical",+ "unit": "mV",+ "min": 85,+ "typ": 100,+ "max": 115,+ "conditions": "1.85 V ≤ VCTL ≤ 2.15 V, VSRT = 1.0 V",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Internal slope compensation voltage",+ "symbol": "VPK",+ "kind": "electrical",+ "unit": "mV",+ "min": 32,+ "typ": 40,+ "max": 50,+ "conditions": "D = DMAX",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Ramp component of ICS",+ "symbol": "ICS_RAMP",+ "kind": "electrical",+ "unit": "µA",+ "min": 12,+ "typ": 16,+ "max": 25,+ "conditions": "D = DMAX",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "DC component of ICS",+ "symbol": "ICSDC",+ "kind": "electrical",+ "unit": "µA",+ "min": 1,+ "typ": 2,+ "max": 3,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Slope compensation ramp start",+ "symbol": "DSLOPE_ST",+ "kind": "electrical",+ "unit": "%",+ "min": 30,+ "typ": 34,+ "max": 39,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Turn off delay",+ "symbol": "t1",+ "kind": "timing",+ "unit": "ns",+ "min": null,+ "typ": 50,+ "max": 90,+ "conditions": "VCS = 0.3 V, measure tprf50–50",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "Blanking period",+ "symbol": "tBLNK",+ "kind": "timing",+ "unit": "ns",+ "min": 100,+ "typ": 150,+ "max": 200,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "CS off state pulldown resistance",+ "symbol": "",+ "kind": "electrical",+ "unit": "Ω",+ "min": null,+ "typ": 290,+ "max": 500,+ "conditions": "",+ "source_page": 6,+ "source": "datasheet"+ },+ {+ "name": "GATE peak source current",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": 0.35,+ "typ": 0.6,+ "max": 1,+ "conditions": "GATE high, pulsed measurement",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "GATE peak sink current",+ "symbol": "",+ "kind": "electrical",+ "unit": "A",+ "min": 0.7,+ "typ": 1,+ "max": 1.4,+ "conditions": "GATE low, pulsed measurement",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "SRD output low voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": null,+ "typ": 0.25,+ "max": 0.45,+ "conditions": "ISRD = 2 mA sinking",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "SRD leakage current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "VCTL = 1.75 V, VSRD = 18 V",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "SRT leakage current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 1,+ "conditions": "0 V ≤ VSRT ≤ 5 V",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "Thermal shutdown (controller)",+ "symbol": "",+ "kind": "electrical",+ "unit": "°C",+ "min": 135,+ "typ": 145,+ "max": 155,+ "conditions": "TJ rising",+ "source_page": 7,+ "source": "datasheet"+ },+ {+ "name": "SLPb threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 1.1,+ "typ": 1.66,+ "max": 2.1,+ "conditions": "VSLPb falling until ILED↑",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "SLPb input pullup current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 4,+ "typ": 5.7,+ "max": 8,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MODE threshold",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 1.1,+ "typ": 1.66,+ "max": 2.1,+ "conditions": "MODE falling until ILED ↑",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MODE input pullup current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 4,+ "typ": 5.7,+ "max": 8,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "WAKE output voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 2.43,+ "typ": 2.5,+ "max": 2.57,+ "conditions": "Sleep mode",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "WAKE pull-up resistance",+ "symbol": "RWKPLUP",+ "kind": "electrical",+ "unit": "kΩ",+ "min": 3.95,+ "typ": 5.33,+ "max": 6.88,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "LED output low voltage",+ "symbol": "",+ "kind": "electrical",+ "unit": "V",+ "min": 0.6,+ "typ": 0.9,+ "max": 1.5,+ "conditions": "SLPb ↓, ILED = 10 mA",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "LED leakage current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": null,+ "max": 10,+ "conditions": "VLED = 18 V",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "Sleep supply current when APD enabled",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": null,+ "typ": 0.5,+ "max": 1,+ "conditions": "VAPD = 2 V; SLPb ↓, measure IVDD",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MPS supply current, pulsed mode",+ "symbol": "",+ "kind": "electrical",+ "unit": "mApk",+ "min": 10,+ "typ": 10.6,+ "max": 11.5,+ "conditions": "VMODE = 0 V; SLPb ↓, 0 ≤ ILED ≤ 10 mA",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MPS supply current, DC mode",+ "symbol": "",+ "kind": "electrical",+ "unit": "mA",+ "min": 10,+ "typ": 10.6,+ "max": 11.5,+ "conditions": "VMODE = VB, then SLPb ↓, 0 ≤ ILED ≤ 10 mA",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MPS pulsed current duty cycle",+ "symbol": "",+ "kind": "electrical",+ "unit": "%",+ "min": 28.8,+ "typ": 28.88,+ "max": 28.95,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MPS pulsed current ON time",+ "symbol": "",+ "kind": "timing",+ "unit": "ms",+ "min": 75,+ "typ": null,+ "max": 87.5,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "MPS pulsed current OFF time",+ "symbol": "",+ "kind": "timing",+ "unit": "ms",+ "min": 215,+ "typ": null,+ "max": 250,+ "conditions": "",+ "source_page": 8,+ "source": "datasheet"+ },+ {+ "name": "DEN bias current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 3,+ "typ": 5,+ "max": 12,+ "conditions": "DEN open, IVDD + IDEN + IRTN, VVDD = 10.1 V, not in mark",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "DEN leakage current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": null,+ "typ": 0.1,+ "max": 5,+ "conditions": "VDEN = VVDD = 57 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Detection current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 53.8,+ "typ": 56.5,+ "max": 58.3,+ "conditions": "IVDD + IDEN + IRTN, VVDD = 1.4 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Detection current",+ "symbol": "",+ "kind": "electrical",+ "unit": "µA",+ "min": 395,+ "typ": 410,+ "max": 417,+ "conditions": "IVDD + IDEN + IRTN, VVDD = 10.1 V",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "DEN disable threshold",+ "symbol": "VPD_DIS",+ "kind": "electrical",+ "unit": "V",+ "min": 3,+ "typ": 3.6,+ "max": 5,+ "conditions": "DEN falling",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "DEN disable hysteresis",+ "symbol": "",+ "kind": "electrical",+ "unit": "mV",+ "min": 50,+ "typ": 113,+ "max": 200,+ "conditions": "",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Classification current",+ "symbol": "ICLS",+ "kind": "electrical",+ "unit": "mA",+ "min": 1.8,+ "typ": 2.17,+ "max": 2.6,+ "conditions": "13 V ≤ VVDD ≤ 21 V, RCLS = 1270 Ω",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Classification current",+ "symbol": "ICLS",+ "kind": "electrical",+ "unit": "mA",+ "min": 9.9,+ "typ": 10.6,+ "max": 11.2,+ "conditions": "13 V ≤ VVDD ≤ 21 V, RCLS = 243 Ω",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Classification current",+ "symbol": "ICLS",+ "kind": "electrical",+ "unit": "mA",+ "min": 17.6,+ "typ": 18.6,+ "max": 19.4,+ "conditions": "13 V ≤ VVDD ≤ 21 V, RCLS = 137 Ω",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Classification current",+ "symbol": "ICLS",+ "kind": "electrical",+ "unit": "mA",+ "min": 26.5,+ "typ": 27.9,+ "max": 29.3,+ "conditions": "13 V ≤ VVDD ≤ 21 V, RCLS = 90.9 Ω",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Classification current",+ "symbol": "ICLS",+ "kind": "electrical",+ "unit": "mA",+ "min": 38,+ "typ": 39.9,+ "max": 42,+ "conditions": "13 V ≤ VVDD ≤ 21 V, RCLS = 63.4 Ω",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Class lower threshold",+ "symbol": "VCL_ON",+ "kind": "electrical",+ "unit": "V",+ "min": 11.9,+ "typ": 12.5,+ "max": 13,+ "conditions": "VVDD rising, VCLS ↑",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Class lower threshold hysteresis",+ "symbol": "VCL_H",+ "kind": "electrical",+ "unit": "V",+ "min": 1.4,+ "typ": 1.6,+ "max": 1.7,+ "conditions": "",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Class upper threshold",+ "symbol": "VCU_OFF",+ "kind": "electrical",+ "unit": "V",+ "min": 21,+ "typ": 22,+ "max": 23,+ "conditions": "VVDD rising, VCLS ↓",+ "source_page": 9,+ "source": "datasheet"+ },+ {+ "name": "Class upper threshold hysteresis",+ "symbol": "VCU_H",+ "kind": "electrical",+ "unit": "V",+ "min": 0.5,+ "typ": 0.75,+ "max": 0.9,+ "conditions": "",+ "source_page": 9,+ "source": "datasheet"+ }+ ]+ }+ },+ "discovery_triggers": [+ "tps23752pwp"+ ],+ "discovery_pitch": "TPS23752PWP (Texas Instruments) component page: datasheet pinout, KiCad symbol, footprint and 3D.",+ "visibility": "public" }
page.json+7−6@@ -4,7 +4,7 @@ "slug": "tps23752pwp", "title": "TPS23752PWP", "brief": "Texas Instruments Power Over Ethernet Controllers, HTSSOP-20. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",- "version": "0.1.0",+ "version": "0.1.1", "license": "CC-BY-SA-4.0", "tags": [ "component",@@ -25,7 +25,7 @@ "symbol": "tps23752pwp.kicad_sym", "footprint": "tps23752pwp.kicad_mod", "model_3d": "tps23752pwp-hero.glb",- "model_3d_plain": "tps23752pwp-etched.glb",+ "model_3d_plain": "tps23752pwp.glb", "model_3d_step": "tps23752pwp-etched.step", "model_3d_step_plain": "tps23752pwp.step", "lbr": "tps23752pwp.lbr"@@ -1214,9 +1214,10 @@ "viewers/footprint.html", "tps23752pwp-hero.glb", "tps23752pwp-hero.overlay.json",- "tps23752pwp-etched.glb"+ "tps23752pwp-etched.glb",+ "tps23752pwp-etched.step" ],- "visibility": {- "public": true- }+ "visibility": "public",+ "description": "Texas Instruments Power Over Ethernet Controllers, HTSSOP-20. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.",+ "org": "adom" }