← Commit history
page.json+7−4@@ -44,19 +44,19 @@ "number": "3", "name": "FLT", "type": "output",- "description": "Active-low open-drain fault output, asserted during overcurrent or overtemperature conditions. Requires an external pull-up resistor (typ. 10k\u03a9) to a logic supply. Sink current 0-5mA."+ "description": "Active-low open-drain fault output, asserted during overcurrent or overtemperature conditions. Requires an external pull-up resistor (typ. 10kΩ) to a logic supply. Sink current 0-5mA." }, { "number": "4", "name": "EN", "type": "input",- "description": "Active-high enable input; logic high turns on the power switch. VIH \u2265 2V, VIL \u2264 0.7V; 0-5.5V input range. TPS2051C is the active-high variant (EN, not EN\u0304)."+ "description": "Active-high enable input; logic high turns on the power switch. VIH ≥ 2V, VIL ≤ 0.7V; 0-5.5V input range. TPS2051C is the active-high variant (EN, not EN̄)." }, { "number": "5", "name": "IN", "type": "power_in",- "description": "Input voltage and power-switch drain (4.5-5.5V). Connect a 0.1\u00b5F or greater ceramic bypass capacitor from IN to GND close to the IC."+ "description": "Input voltage and power-switch drain (4.5-5.5V). Connect a 0.1µF or greater ceramic bypass capacitor from IN to GND close to the IC." } ], "provenance": {@@ -120,5 +120,8 @@ "docs/tps2051cdbvr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }