← Commit history
page.json+11−8@@ -44,43 +44,43 @@ "number": "2", "name": "SNS", "type": "output",- "description": "Proportional current sense output sourcing IOUT/KSNS (KSNS=1500) when SEL1=0, or temperature sense current (dISNST/dT=0.0112 mA/\u00b0C) when SEL1=1, or ISNSFH (4.5 mA typ) during fault indication."+ "description": "Proportional current sense output sourcing IOUT/KSNS (KSNS=1500) when SEL1=0, or temperature sense current (dISNST/dT=0.0112 mA/°C) when SEL1=1, or ISNSFH (4.5 mA typ) during fault indication." }, { "number": "3", "name": "LATCH", "type": "input",- "description": "Latch control input with 350 mV hysteresis; high level (VIH\u22652.0V) latches output after fault events, low level (VIL<0.8V) enables auto-retry after tRETRY (1-3 ms) expiration."+ "description": "Latch control input with 350 mV hysteresis; high level (VIH≥2.0V) latches output after fault events, low level (VIL<0.8V) enables auto-retry after tRETRY (1-3 ms) expiration." }, { "number": "4", "name": "EN", "type": "input",- "description": "Active-high enable control input with 350 mV hysteresis; high level (VIH\u22652.0V) enables output switch, low level (VIL<0.8V) disables output."+ "description": "Active-high enable control input with 350 mV hysteresis; high level (VIH≥2.0V) enables output switch, low level (VIL<0.8V) disables output." }, { "number": "5", "name": "ILIM", "type": "output",- "description": "Programmable current limit threshold output; connect external resistor (RILIM 5 k\u03a9 to 25 k\u03a9) from this pin to VBB to set current limit (ICL = KCL / RILIM)."+ "description": "Programmable current limit threshold output; connect external resistor (RILIM 5 kΩ to 25 kΩ) from this pin to VBB to set current limit (ICL = KCL / RILIM)." }, { "number": "6", "name": "VOUT", "type": "output",- "description": "High-side switch output pin (one of three parallel pins); RON 50 m\u03a9 at TJ=25\u00b0C and 100 m\u03a9 at TJ=150\u00b0C, with VDS clamp voltage 40-46V for inductive load protection."+ "description": "High-side switch output pin (one of three parallel pins); RON 50 mΩ at TJ=25°C and 100 mΩ at TJ=150°C, with VDS clamp voltage 40-46V for inductive load protection." }, { "number": "7", "name": "VOUT", "type": "output",- "description": "High-side switch output pin (one of three parallel pins); RON 50 m\u03a9 at TJ=25\u00b0C and 100 m\u03a9 at TJ=150\u00b0C, with VDS clamp voltage 40-46V for inductive load protection."+ "description": "High-side switch output pin (one of three parallel pins); RON 50 mΩ at TJ=25°C and 100 mΩ at TJ=150°C, with VDS clamp voltage 40-46V for inductive load protection." }, { "number": "8", "name": "VOUT", "type": "output",- "description": "High-side switch output pin (one of three parallel pins); RON 50 m\u03a9 at TJ=25\u00b0C and 100 m\u03a9 at TJ=150\u00b0C, with VDS clamp voltage 40-46V for inductive load protection."+ "description": "High-side switch output pin (one of three parallel pins); RON 50 mΩ at TJ=25°C and 100 mΩ at TJ=150°C, with VDS clamp voltage 40-46V for inductive load protection." }, { "number": "9",@@ -212,5 +212,8 @@ "docs/tps1hb50aqpwprq1-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }