component
TPS1HA08CQPWPRQ1
Public Made by Adomby adom
Texas Instruments Power Distribution Switches, HTSSOP-16-EP. Pinout cross-checked by two models against the datasheet, KiCad symbol/footprint/3D.
← Commit history
page.json+17−14@@ -59,61 +59,61 @@ "number": "2", "name": "SNS", "type": "output",- "description": "Analog sensing output providing load current (ISNSI = IOUT/4600), supply voltage (ISNSV = 0.0867mA/V), or device temperature (dISNST/dT = 0.0112mA/\u00b0C) with VSNSclamp = 5.9V and fault indication ISNSFH = 6.0-7.6mA."+ "description": "Analog sensing output providing load current (ISNSI = IOUT/4600), supply voltage (ISNSV = 0.0867mA/V), or device temperature (dISNST/dT = 0.0112mA/°C) with VSNSclamp = 5.9V and fault indication ISNSFH = 6.0-7.6mA." }, { "number": "3", "name": "LATCH", "type": "input",- "description": "Fault latch control input; high enables auto-retry after fault, low holds fault latch state; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+ "description": "Fault latch control input; high enables auto-retry after fault, low holds fault latch state; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down." }, { "number": "4", "name": "EN", "type": "input",- "description": "Switch enable control input, active high; enables output when voltage > 2V, disables when < 0.8V; voltage range -1 to 5.5V with internal 1M\u03a9 pull-down."+ "description": "Switch enable control input, active high; enables output when voltage > 2V, disables when < 0.8V; voltage range -1 to 5.5V with internal 1MΩ pull-down." }, { "number": "5", "name": "ST", "type": "output",- "description": "Open-drain fault status output; pulls low (VOL = 0.4V @ IST = 1mA, ISTleak = 2\u00b5A @ VST = 5V) on thermal shutdown, current limit, energy limit, or open-load/short-to-battery detection."+ "description": "Open-drain fault status output; pulls low (VOL = 0.4V @ IST = 1mA, ISTleak = 2µA @ VST = 5V) on thermal shutdown, current limit, energy limit, or open-load/short-to-battery detection." }, { "number": "6", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "7", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "8", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "9", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "10", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "11", "name": "VOUT", "type": "output",- "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+ "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating." }, { "number": "12",@@ -131,19 +131,19 @@ "number": "14", "name": "SEL1", "type": "input",- "description": "Diagnostic multiplexer select input 1; low selects load current in SNS output, high selects device temperature; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+ "description": "Diagnostic multiplexer select input 1; low selects load current in SNS output, high selects device temperature; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down." }, { "number": "15", "name": "SEL2", "type": "input",- "description": "Diagnostic multiplexer select input 2; combined with SEL1 to select SNS output between current/temperature (low) and supply voltage (high); voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+ "description": "Diagnostic multiplexer select input 2; combined with SEL1 to select SNS output between current/temperature (low) and supply voltage (high); voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down." }, { "number": "16", "name": "DIA_EN", "type": "input",- "description": "Diagnostic enable control input, active high; enables analog sensing output, open-load detection, and short-to-battery detection when high; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+ "description": "Diagnostic enable control input, active high; enables analog sensing output, open-load detection, and short-to-battery detection when high; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down." }, { "number": "17",@@ -231,5 +231,8 @@ "docs/tps1ha08cqpwprq1-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }