← Commit history

Set visibility: public

Ray ·79bb73e958 ·4d ago ·parent 3af9019
1 file changed +17−14
page.json+17−14
@@ -59,61 +59,61 @@         "number": "2",         "name": "SNS",         "type": "output",-        "description": "Analog sensing output providing load current (ISNSI = IOUT/4600), supply voltage (ISNSV = 0.0867mA/V), or device temperature (dISNST/dT = 0.0112mA/\u00b0C) with VSNSclamp = 5.9V and fault indication ISNSFH = 6.0-7.6mA."+        "description": "Analog sensing output providing load current (ISNSI = IOUT/4600), supply voltage (ISNSV = 0.0867mA/V), or device temperature (dISNST/dT = 0.0112mA/°C) with VSNSclamp = 5.9V and fault indication ISNSFH = 6.0-7.6mA."       },       {         "number": "3",         "name": "LATCH",         "type": "input",-        "description": "Fault latch control input; high enables auto-retry after fault, low holds fault latch state; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+        "description": "Fault latch control input; high enables auto-retry after fault, low holds fault latch state; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down."       },       {         "number": "4",         "name": "EN",         "type": "input",-        "description": "Switch enable control input, active high; enables output when voltage > 2V, disables when < 0.8V; voltage range -1 to 5.5V with internal 1M\u03a9 pull-down."+        "description": "Switch enable control input, active high; enables output when voltage > 2V, disables when < 0.8V; voltage range -1 to 5.5V with internal 1MΩ pull-down."       },       {         "number": "5",         "name": "ST",         "type": "output",-        "description": "Open-drain fault status output; pulls low (VOL = 0.4V @ IST = 1mA, ISTleak = 2\u00b5A @ VST = 5V) on thermal shutdown, current limit, energy limit, or open-load/short-to-battery detection."+        "description": "Open-drain fault status output; pulls low (VOL = 0.4V @ IST = 1mA, ISTleak = 2µA @ VST = 5V) on thermal shutdown, current limit, energy limit, or open-load/short-to-battery detection."       },       {         "number": "6",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "7",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "8",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "9",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "10",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "11",         "name": "VOUT",         "type": "output",-        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20m\u03a9 (TJ 25-150\u00b0C), supports 10A continuous at 70\u00b0C ambient, one of six parallel output nodes; 40V maximum load transient rating."+        "description": "Power switch output; connects VBB to load when enabled with RON = 8-20mΩ (TJ 25-150°C), supports 10A continuous at 70°C ambient, one of six parallel output nodes; 40V maximum load transient rating."       },       {         "number": "12",@@ -131,19 +131,19 @@         "number": "14",         "name": "SEL1",         "type": "input",-        "description": "Diagnostic multiplexer select input 1; low selects load current in SNS output, high selects device temperature; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+        "description": "Diagnostic multiplexer select input 1; low selects load current in SNS output, high selects device temperature; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down."       },       {         "number": "15",         "name": "SEL2",         "type": "input",-        "description": "Diagnostic multiplexer select input 2; combined with SEL1 to select SNS output between current/temperature (low) and supply voltage (high); voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+        "description": "Diagnostic multiplexer select input 2; combined with SEL1 to select SNS output between current/temperature (low) and supply voltage (high); voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down."       },       {         "number": "16",         "name": "DIA_EN",         "type": "input",-        "description": "Diagnostic enable control input, active high; enables analog sensing output, open-load detection, and short-to-battery detection when high; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1M\u03a9 pull-down."+        "description": "Diagnostic enable control input, active high; enables analog sensing output, open-load detection, and short-to-battery detection when high; voltage range -1 to 5.5V with VIL = 0.8V, VIH = 2V, VIhys = 250mV, and internal 1MΩ pull-down."       },       {         "number": "17",@@ -231,5 +231,8 @@     "docs/tps1ha08cqpwprq1-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file