← Commit history
page.json+7−4@@ -32,7 +32,7 @@ "number": "1", "name": "IN", "type": "power_in",- "description": "Input voltage pin, 2.4 V to 6 V (abs max 6.5 V). Bypass IN to GND with a 1 \u00b5F or greater ceramic capacitor placed close to the pin."+ "description": "Input voltage pin, 2.4 V to 6 V (abs max 6.5 V). Bypass IN to GND with a 1 µF or greater ceramic capacitor placed close to the pin." }, { "number": "2",@@ -44,7 +44,7 @@ "number": "3", "name": "EN", "type": "input",- "description": "Regulator enable input. Drive EN high (V_IH \u2265 1.2 V, up to V_IN) to turn on the regulator; drive EN low (V_IL \u2264 0.4 V) to shut it down. For automatic startup tie EN directly to IN. EN pin leakage is ~20 nA typ."+ "description": "Regulator enable input. Drive EN high (V_IH ≥ 1.2 V, up to V_IN) to turn on the regulator; drive EN low (V_IL ≤ 0.4 V) to shut it down. For automatic startup tie EN directly to IN. EN pin leakage is ~20 nA typ." }, { "number": "4",@@ -56,7 +56,7 @@ "number": "5", "name": "OUT", "type": "power_out",- "description": "Regulated 1.8 V output pin, up to 400 mA. Bypass OUT to GND with a 2.2 \u00b5F or greater low-ESR ceramic capacitor for stability; an active output discharge path pulls OUT down (~190 \u03a9) when the regulator is disabled."+ "description": "Regulated 1.8 V output pin, up to 400 mA. Bypass OUT to GND with a 2.2 µF or greater low-ESR ceramic capacitor for stability; an active output discharge path pulls OUT down (~190 Ω) when the regulator is disabled." } ], "provenance": {@@ -120,5 +120,8 @@ "docs/tpl720f18-5tr-datasheet.pdf", "viewers/symbol.html", "viewers/footprint.html"- ]+ ],+ "visibility": {+ "public": true+ } }