← Commit history

Set visibility: public

Ray ·958a58df40 ·1mo ago ·parent db4e31c
1 file changed +8−5
page.json+8−5
@@ -32,13 +32,13 @@         "number": "1",         "name": "SELECT",         "type": "input",-        "description": "Digital channel-select control input. 1.8V logic compatible: L selects NC channel (COM\u2194NC), H selects NO channel (COM\u2194NO). VIH \u2265 1.6V (VCC=3.3-5.5V) or \u2265 1.4V (VCC=1.5-3.3V); VIL \u2264 0.6V / 0.4V respectively. Absolute max VSEL = -0.3 to +5.5V."+        "description": "Digital channel-select control input. 1.8V logic compatible: L selects NC channel (COM↔NC), H selects NO channel (COM↔NO). VIH ≥ 1.6V (VCC=3.3-5.5V) or ≥ 1.4V (VCC=1.5-3.3V); VIL ≤ 0.6V / 0.4V respectively. Absolute max VSEL = -0.3 to +5.5V."       },       {         "number": "2",         "name": "V+",         "type": "power_in",-        "description": "Positive supply voltage input (VCC). Operating range 1.5V to 5.5V; absolute max -0.3 to +6.5V. Typical quiescent current ICC < 1\u00b5A."+        "description": "Positive supply voltage input (VCC). Operating range 1.5V to 5.5V; absolute max -0.3 to +6.5V. Typical quiescent current ICC < 1µA."       },       {         "number": "3",@@ -50,7 +50,7 @@         "number": "4",         "name": "NC",         "type": "bidirectional",-        "description": "Normally-Closed switch terminal. Independent input or output of the SPDT analog switch; connected to COM when SELECT = L. Ron \u2248 1.7\u03a9 at VA=5V; bidirectional analog signal path (-0.3 to +5.5V, \u00b1128 mA continuous)."+        "description": "Normally-Closed switch terminal. Independent input or output of the SPDT analog switch; connected to COM when SELECT = L. Ron ≈ 1.7Ω at VA=5V; bidirectional analog signal path (-0.3 to +5.5V, ±128 mA continuous)."       },       {         "number": "5",@@ -62,7 +62,7 @@         "number": "6",         "name": "NO",         "type": "bidirectional",-        "description": "Normally-Open switch terminal. Independent input or output of the SPDT analog switch; connected to COM when SELECT = H. Ron \u2248 1.7\u03a9 at VA=5V; bidirectional analog signal path (-0.3 to +5.5V, \u00b1128 mA continuous)."+        "description": "Normally-Open switch terminal. Independent input or output of the SPDT analog switch; connected to COM when SELECT = H. Ron ≈ 1.7Ω at VA=5V; bidirectional analog signal path (-0.3 to +5.5V, ±128 mA continuous)."       }     ],     "provenance": {@@ -126,5 +126,8 @@     "docs/tpg4599s6-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file