← Commit history

Set visibility: public

Ray ·b0a28ee7a2 ·1mo ago ·parent 1f796c5
1 file changed +9−6
page.json+9−6
@@ -38,7 +38,7 @@         "number": "2",         "name": "NO1",         "type": "passive",-        "description": "Normally-open analog/digital signal port for switch 1. Connects to COM1 when IN1=1. Signal voltage range -0.3V to 5.5V; continuous current \u00b1100mA max."+        "description": "Normally-open analog/digital signal port for switch 1. Connects to COM1 when IN1=1. Signal voltage range -0.3V to 5.5V; continuous current ±100mA max."       },       {         "number": "3",@@ -50,7 +50,7 @@         "number": "4",         "name": "NO2",         "type": "passive",-        "description": "Normally-open analog/digital signal port for switch 2. Connects to COM2 when IN2=1. Signal voltage range -0.3V to 5.5V; continuous current \u00b1100mA max."+        "description": "Normally-open analog/digital signal port for switch 2. Connects to COM2 when IN2=1. Signal voltage range -0.3V to 5.5V; continuous current ±100mA max."       },       {         "number": "5",@@ -68,19 +68,19 @@         "number": "7",         "name": "NC2",         "type": "passive",-        "description": "Normally-closed analog/digital signal port for switch 2. Connects to COM2 when IN2=0. Signal voltage range -0.3V to 5.5V; continuous current \u00b1100mA max."+        "description": "Normally-closed analog/digital signal port for switch 2. Connects to COM2 when IN2=0. Signal voltage range -0.3V to 5.5V; continuous current ±100mA max."       },       {         "number": "8",         "name": "VCC",         "type": "power_in",-        "description": "Supply voltage input. Operating range 1.5V to 5.5V; absolute max 6.5V. Quiescent current <2\u03bcA (typ) / 1.0\u03bcA max."+        "description": "Supply voltage input. Operating range 1.5V to 5.5V; absolute max 6.5V. Quiescent current <2μA (typ) / 1.0μA max."       },       {         "number": "9",         "name": "NC1",         "type": "passive",-        "description": "Normally-closed analog/digital signal port for switch 1. Connects to COM1 when IN1=0. Signal voltage range -0.3V to 5.5V; continuous current \u00b1100mA max."+        "description": "Normally-closed analog/digital signal port for switch 1. Connects to COM1 when IN1=0. Signal voltage range -0.3V to 5.5V; continuous current ±100mA max."       },       {         "number": "10",@@ -150,5 +150,8 @@     "docs/tpg23159m10-datasheet.pdf",     "viewers/symbol.html",     "viewers/footprint.html"-  ]+  ],+  "visibility": {+    "public": true+  } }\ No newline at end of file