← Commit history

tn2010h-6i: specified limits as data (metadata.characteristics, 31 rows from the datasheet)

Ray ·8ca108da88 · ·parent 4efda5d
2 files changed +417
README.md+38
@@ -21,6 +21,44 @@ TN2010H-6I from STMicroelectronics, in a TO-220AB. Pinout and pin descriptions e | Category | Transistors/Thyristors | | Pins | 3 | +## Electrical characteristics++Limits as printed in the datasheet (page.json `metadata.characteristics` carries them as data).++| Parameter | Symbol | Min | Typ | Max | Unit | Conditions | Page |+|---|---|---|---|---|---|---|---|+| Repetitive peak off-state voltage | VDRM/VRRM |  |  | 600 | V |  | 2 |+| RMS on-state current (180° conduction angle) | IT(RMS) |  |  | 20 | A | Tc = 113 °C | 2 |+| Average on-state current (180° conduction angle) | IT(AV) |  |  | 13 | A | Tc = 112 °C | 2 |+| Average on-state current (180° conduction angle) | IT(AV) |  |  | 8 | A | Tc = 130 °C | 2 |+| Average on-state current (180° conduction angle) | IT(AV) |  |  | 5 | A | Tc = 139 °C | 2 |+| Non repetitive surge peak on-state current | ITSM |  |  | 197 | A | Tj initial = 25 °C, tp = 8.3 ms | 2 |+| Non repetitive surge peak on-state current | ITSM |  |  | 180 | A | Tj initial = 25 °C, tp = 10 ms | 2 |+| I2t value for fusing | I2t |  |  | 162 | A2s | Tj initial = 25 °C, tp = 10 ms | 2 |+| Critical rate of rise of on-state current | dI/dt |  |  | 100 | A/µs | IG = 2 x IGT, tr ≤ 100 ns, f = 60 Hz | 2 |+| Peak gate current | IGM |  |  | 4 | A | tp = 20 µs, Tj = 150 °C | 2 |+| Average gate power dissipation | PG(AV) |  |  | 1 | W | Tj = 150 °C | 2 |+| Maximum peak reverse voltage | VRGM |  |  | 5 | V |  | 2 |+| Storage junction temperature range | Tstg | -40 |  | 150 | °C |  | 2 |+| Maximum operating junction temperature | Tj | -40 |  | 150 | °C |  | 2 |+| Maximum lead temperature for soldering during 10 s | Tl |  |  | 260 | °C | during 10 s | 2 |+| Insulation rms voltage | Viso |  |  | 2500 | V | 1 minute | 2 |+| Gate trigger current | IGT |  | 5 | 10 | mA | VD = 12 V, RL = 33 Ω | 2 |+| Gate trigger voltage | VGT |  |  | 1.3 | V |  | 2 |+| Gate non-trigger voltage | VGD | 0.1 |  |  | V | VD = VDRM, RL = 3.3 kΩ, Tj = 150 °C | 2 |+| Holding current | IH |  |  | 40 | mA | IT = 500 mA, gate open | 2 |+| Latching current | IL |  |  | 60 | mA | IG = 1.2 x IGT | 2 |+| Critical rate of rise of off-state voltage | dV/dt | 400 |  |  | V/µs | VD = 402 V, gate open, Tj = 150 °C | 2 |+| Gate-controlled turn-on time | tgt |  | 1.9 |  | µs | IT = 40 A, VD = 402 V, IG = 20 mA, (dIG/dt) max = 0.2 A/µs | 2 |+| Turn-off time | tq |  | 70 |  | µs | IT = 20 A, VD = 402 V, (dIG/dt) max = 30 A/µs, VR = 25 V, dVD/dt = 40 V/µs, Tj = 150 °C | 2 |+| On-state voltage | VTM |  |  | 1.6 | V | IT = 40 A, tp = 380 µs, Tj = 25 °C | 3 |+| Threshold voltage | VTO |  |  | 0.82 | V | Tj = 150 °C | 3 |+| Dynamic resistance | RD |  |  | 17.5 | mΩ | Tj = 150 °C | 3 |+| Repetitive peak off-state and reverse current | IDRM, IRRM |  |  | 5 | µA | VD = VDRM; VR = VRRM, Tj = 25 °C | 3 |+| Repetitive peak off-state and reverse current | IDRM, IRRM |  |  | 3.9 | mA | VD = VDRM; VR = VRRM, Tj = 150 °C | 3 |+| Junction to case thermal resistance (DC) | Rth(j-c) |  |  | 2.1 | °C/W | DC | 3 |+| Junction to ambient thermal resistance (DC) | Rth(j-a) |  | 60 |  | °C/W | DC | 3 |+ ## CAD (KiCad official)  - Symbol: `TN2010H-6I`
page.json+379
@@ -150,6 +150,385 @@       "Package": "TO-220AB",       "Category": "Transistors/Thyristors",       "Pins": "3"+    },+    "characteristics": {+      "version": 1,+      "source": "datasheet",+      "datasheet_sha256": "9a64a025f69125ed",+      "rows": [+        {+          "name": "Repetitive peak off-state voltage",+          "symbol": "VDRM/VRRM",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 600,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "RMS on-state current (180° conduction angle)",+          "symbol": "IT(RMS)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 20,+          "conditions": "Tc = 113 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average on-state current (180° conduction angle)",+          "symbol": "IT(AV)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 13,+          "conditions": "Tc = 112 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average on-state current (180° conduction angle)",+          "symbol": "IT(AV)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 8,+          "conditions": "Tc = 130 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average on-state current (180° conduction angle)",+          "symbol": "IT(AV)",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "Tc = 139 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non repetitive surge peak on-state current",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 197,+          "conditions": "Tj initial = 25 °C, tp = 8.3 ms",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Non repetitive surge peak on-state current",+          "symbol": "ITSM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 180,+          "conditions": "Tj initial = 25 °C, tp = 10 ms",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "I2t value for fusing",+          "symbol": "I2t",+          "kind": "absolute_maximum",+          "unit": "A2s",+          "min": null,+          "typ": null,+          "max": 162,+          "conditions": "Tj initial = 25 °C, tp = 10 ms",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of on-state current",+          "symbol": "dI/dt",+          "kind": "absolute_maximum",+          "unit": "A/µs",+          "min": null,+          "typ": null,+          "max": 100,+          "conditions": "IG = 2 x IGT, tr ≤ 100 ns, f = 60 Hz",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Peak gate current",+          "symbol": "IGM",+          "kind": "absolute_maximum",+          "unit": "A",+          "min": null,+          "typ": null,+          "max": 4,+          "conditions": "tp = 20 µs, Tj = 150 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Average gate power dissipation",+          "symbol": "PG(AV)",+          "kind": "absolute_maximum",+          "unit": "W",+          "min": null,+          "typ": null,+          "max": 1,+          "conditions": "Tj = 150 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum peak reverse voltage",+          "symbol": "VRGM",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Storage junction temperature range",+          "symbol": "Tstg",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum operating junction temperature",+          "symbol": "Tj",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": -40,+          "typ": null,+          "max": 150,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Maximum lead temperature for soldering during 10 s",+          "symbol": "Tl",+          "kind": "absolute_maximum",+          "unit": "°C",+          "min": null,+          "typ": null,+          "max": 260,+          "conditions": "during 10 s",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Insulation rms voltage",+          "symbol": "Viso",+          "kind": "absolute_maximum",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 2500,+          "conditions": "1 minute",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate trigger current",+          "symbol": "IGT",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": 5,+          "max": 10,+          "conditions": "VD = 12 V, RL = 33 Ω",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate trigger voltage",+          "symbol": "VGT",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.3,+          "conditions": "",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate non-trigger voltage",+          "symbol": "VGD",+          "kind": "electrical",+          "unit": "V",+          "min": 0.1,+          "typ": null,+          "max": null,+          "conditions": "VD = VDRM, RL = 3.3 kΩ, Tj = 150 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Holding current",+          "symbol": "IH",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 40,+          "conditions": "IT = 500 mA, gate open",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Latching current",+          "symbol": "IL",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 60,+          "conditions": "IG = 1.2 x IGT",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Critical rate of rise of off-state voltage",+          "symbol": "dV/dt",+          "kind": "electrical",+          "unit": "V/µs",+          "min": 400,+          "typ": null,+          "max": null,+          "conditions": "VD = 402 V, gate open, Tj = 150 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Gate-controlled turn-on time",+          "symbol": "tgt",+          "kind": "electrical",+          "unit": "µs",+          "min": null,+          "typ": 1.9,+          "max": null,+          "conditions": "IT = 40 A, VD = 402 V, IG = 20 mA, (dIG/dt) max = 0.2 A/µs",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "Turn-off time",+          "symbol": "tq",+          "kind": "electrical",+          "unit": "µs",+          "min": null,+          "typ": 70,+          "max": null,+          "conditions": "IT = 20 A, VD = 402 V, (dIG/dt) max = 30 A/µs, VR = 25 V, dVD/dt = 40 V/µs, Tj = 150 °C",+          "source_page": 2,+          "source": "datasheet"+        },+        {+          "name": "On-state voltage",+          "symbol": "VTM",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 1.6,+          "conditions": "IT = 40 A, tp = 380 µs, Tj = 25 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Threshold voltage",+          "symbol": "VTO",+          "kind": "electrical",+          "unit": "V",+          "min": null,+          "typ": null,+          "max": 0.82,+          "conditions": "Tj = 150 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Dynamic resistance",+          "symbol": "RD",+          "kind": "electrical",+          "unit": "mΩ",+          "min": null,+          "typ": null,+          "max": 17.5,+          "conditions": "Tj = 150 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Repetitive peak off-state and reverse current",+          "symbol": "IDRM, IRRM",+          "kind": "electrical",+          "unit": "µA",+          "min": null,+          "typ": null,+          "max": 5,+          "conditions": "VD = VDRM; VR = VRRM, Tj = 25 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Repetitive peak off-state and reverse current",+          "symbol": "IDRM, IRRM",+          "kind": "electrical",+          "unit": "mA",+          "min": null,+          "typ": null,+          "max": 3.9,+          "conditions": "VD = VDRM; VR = VRRM, Tj = 150 °C",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Junction to case thermal resistance (DC)",+          "symbol": "Rth(j-c)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": null,+          "max": 2.1,+          "conditions": "DC",+          "source_page": 3,+          "source": "datasheet"+        },+        {+          "name": "Junction to ambient thermal resistance (DC)",+          "symbol": "Rth(j-a)",+          "kind": "thermal",+          "unit": "°C/W",+          "min": null,+          "typ": 60,+          "max": null,+          "conditions": "DC",+          "source_page": 3,+          "source": "datasheet"+        }+      ]     }   },   "variants": [],